6.1.3 Temperature
°C
– this parameter allows to check the dimmer internal temperature in
the range -40 to +125°C.
NOTE! Message
Er1
means sensor failure, so service is necessary.
6.1.4 Input control mode
AdC
– switching between default digital control mode (DMX-512, setting
OFF
) and analog mode (0 – 10V control signal or external button – setting
On
).
6.1.5 Scenes and chaser programming
1.
Sc1
…
Sc4
– scenes programming:
◦
C01
…
C04
– edited channel number
▪
0
…
100
– channel brightness in percentage %
2.
CrP
– user-defined chaser:
◦
F01
…
F08
– editable pattern numbers
▪
C01
…
C04
– edited channel number
•
0
…
100
– channel brightness in percentage %
◦
LEn
– chaser step number (1 to 8)
◦
SPd
– chaser speed from 1 (255 seconds) to 32 (0.1 second)
◦
FAd
– scenes fading function switching on or off
3.
CrF
– built-in chaser:
◦
SPd
– chaser speed from 1 (255 seconds) to 32 (0.1 second)
◦
FAd
– scenes fading function switching on or off
13