background image

6

The PX319 driver is equipped with an additional DIP-Switch which allows you to set the No Signal 
function, responding to the driver action when it does not receive the DMX signal.

With this switch, it is possible to set one of 

4

 brightness levels. The brightness increases from the 

smallest (zero) to the maximum one, in accordance with the binary markings on the “DIP switch”. 
Below are brightness levels and the corresponding switch settings.

2 3 4 5 6 7 8 9

ON

DIP

1

10

With  the  smooth  function  enabled,  transitions  between  successive  control  signal  values  are 
smoothed, allowing for smooth changes in the brightness of the connected LEDs. This prevents 
the light “vibration” effect that usually occurs in lighting systems when light intensity is being 
changed

.

The “smooth” function and 

DMX address set to 1

.

5.1. SMOOTH FUNCTION SETTINGS

5.2. NO SIGNAL FUNCTION SETTINGS

2 3

ON

1

2 3

ON

1

2 3

ON

1

2 3

ON

1

0

1

2

3

 

Zero brightness level

 1 

brightness level

 2 

brightness level

 3 

brightness level

5.3. 

PWM FREQUENCY SETTINGS

You can set PWM frequencies using individual switch position no. 3 on the DIP switch:

2 3

ON

1

Zero brightness level and PWM frequency of 366 Hz

2 3

ON

1

Zero brightness level and PWM frequency of >20 kHz

Содержание Driver LED 1x2A/48V

Страница 1: ...MANUAL Driver LED 1x2A 48V PX319 R ...

Страница 2: ... Podłęże 654 32 003 Podłęże 3 3 4 4 5 6 6 6 7 8 9 10 10 11 1 General description 2 Safety conditions 3 Connections and control elements description 4 DMX indicator light meanings 5 DMX address setting 5 1 Smooth function settings 5 2 No Signal function settings 5 3 PWM frequency settings 6 Driver output current setting 6 1Temperature control 7 Connection diagram 8 Technical drawing 9 Technical dat...

Страница 3: ...afety conditions It is necessary to observe the following rules 1 The device can be connected to 12 48 V DC stabilised voltage with current carrying capacity compatible with technical data 2 All the conductors should be protected against mechanical and thermal damage 3 In case of damage to a conductor it should be replaced with a conductor of the same technical parameters 4 Connection of DMX signa...

Страница 4: ...ut limiting the output current temperature sensor input 4 DMX INDICATOR LIGHT MEANINGS The driver is equipped with one indicator light Status Function the diode is emitting constant light No Signal mode operation the driver is not receiving any DMX signal the diode is blinking a DMX signal is being received No signal and PWM frequency mode switch ...

Страница 5: ...he address the tenth switch is responsible for activating the smooth function 2 3 4 5 6 7 8 9 ON DIP 1 2 3 4 5 6 7 8 9 ON DIP 1 2 3 4 5 6 7 8 9 ON DIP 1 10 10 10 2 3 4 5 6 7 8 9 ON DIP 1 10 2 3 4 5 6 7 8 9 ON DIP 1 10 2 3 4 5 6 7 8 9 ON DIP 1 10 2 3 4 5 6 7 8 9 ON DIP 1 2 3 4 5 6 7 8 9 ON DIP 1 10 10 2 3 4 5 6 7 8 9 ON DIP 1 10 9 10 Off On The white colour is a switch It is ON when set in the uppe...

Страница 6: ...itions between successive control signal values are smoothed allowing for smooth changes in the brightness of the connected LEDs This prevents the light vibration effect that usually occurs in lighting systems when light intensity is being changed The smooth function and DMX address set to 1 5 1 SMOOTH FUNCTION SETTINGS 5 2 NO SIGNAL FUNCTION SETTINGS 2 3 ON 1 2 3 ON 1 2 3 ON 1 2 3 ON 1 0 1 2 3 Ze...

Страница 7: ...500 mA 7k5 1600 mA 8k2 1750 mA 10k 1800 mA 12k 2000 mA 15k The PX319 driver is equipped with a function to set the output current controlling linear LED modules Depending on the number of modules connected to the device it is necessary to select the control current by choosing a resistor with the appropriate resistance The table below shows the correct selection of resistors 6 DRIVER OUTPUT CURREN...

Страница 8: ...ure coefficient None 20 Silver x0 01 10 Gold x0 1 5 Black 0 x1 Brown 1 x10 1 Red 2 x100 2 Orange 3 x1000 Yellow 4 x10 000 Green 5 x100 000 0 50 Blue 6 x1000 000 0 25 Purple 7 x10 000 000 0 10 Grey 8 x100 000 000 White 9 x1000 000 000 Example of the resistor identification Irrelevant You can connect an external 4K7 thermistor to the driver As the temperature exceeds 70ºC the driver starts to limit ...

Страница 9: ...he terminator resistor of 120 Ohm between pins and 120 Ohm CORRECT INCORRECT 9 DMX 512 input DMX 512 output DMX cable 7 CONNECTION DIAGRAM linear LED module to successive modules DMX controller 1 2 3 4 5 6 PX015 1 2 3 4 5 6 Chaser Scene Club 6p 90 100 80 70 60 50 40 30 20 10 0 100 90 80 70 60 50 40 30 20 10 0 Master Music Speed GND DMX DMX 12 48 V DC power supply unit V V L N linear LED module DC ...

Страница 10: ...mm 21 mm DMX channels Output channels number Power supply Maximum current consumption Power consumption without load Scene brightness Output load Output sockets Weight Dimensions Width Height Length 9 TECHNICAL SPECIFICATION 10 8 TECHNICAL DRAWING 132 mm 21 mm 47 mm 124 mm FRQ ...

Страница 11: ... Żupnik Name of producer Manufacturer s address We declare that our product Product name Product code complies with the following standards EMC Additional information Kraków 04 12 2014 DECLARATION OF CONFORMITY according to guide line 2004 108 WE Konsole teatralne i estradowE Cyfrowe ściemniacze mocy SYSTEM dmx Sterowniki ARCHITEKTONICZNE OŚWIETLENIE LED tel 12 626 46 92 fax 12 626 46 94 e mail in...

Отзывы: