5.11 Adjusting the operative temperature 

Pump series EU W are equipped with a water/oil cooler; on the water circuit 
a  thermostatic  valve  is  installed  (Fig.1)  for  the  regulation  of  the  water 
throughput according to the required different cooling requirements. 

The specifications of the cooling water are shown below:: 

Minimum / Maximum water pressure 

bar 

2 / 6 

Water consumption 

l/h 

200-300 

Water temperature 

°C 

10-30 

Water hardness 

°fH 

4-8 

The  thermostatic  valve  is  set  by  P.V.R.  on  the  position  3  in  order  to 
guarantee a pump operating temperature of 80°C (ambient temperature 
20°C  -  water  temperature  15°C).  The  valve  can  be  set  in  one  position 
from  1  to  5  on  the  grounds  of  the  foreseen  application.  Position  one 
corresponds to a greater water quantity at the cooler inlet and therefore 
to  a  higher  cooling  of  the  pump,  the  position  No.  5  corresponds  to  a 
smaller  rate of  water for a  lower  thermal  exchange. For the  setting turn 
the  knob  counter-clockwise  to  rise  the  temperature  and  clockwise  to 
reduce it. 

6. SERVICING 

 

6.1 General information 

Vedi LI1586 

6.2 Oil change 

See LI1586 

6.3 Coupling elastic element replacement 

See LI1586 

6.4 Exhaust filters replacement 

See LI1586 

6.5 Float valve 

See LI1586 

6.6 Pump overhaul 

See LI1586 

6.7 Spares necessary for the normal servicing 

See LI1586 

6.8 How to order spare parts 

See LI1586 

 

 

 

SERVICING FREQUENCY 

DESCRIPTION OF THE OPERATION 

AUTHORIZED PERSONNEL 

2000 

Hours/every year 

Check the cooling circuit and the water/oil heat exchanger, if necessary 
clean the passages water and oil.  

Skilled Worker 

 

6.9 How to service the cooling circuit.  

  WARNING

:  Carry out  the  maintenance operations only  with  the 

pump not operating and at a safe temperature

 

To  guarantee  the  maximum  performance  of  the  cooler,  it  is  advisable  to 
inspect the water circuit and  remove any  traces of limestone  or impurities. 
For cleaning, proceed as follows: 

1)

 Drain the oil from the pump (see 6.2); 

2)

 

Disconnect the pump from the water circuit (see 5.10); 

3) 

Drain  the  water  from  the  heat  exchanger  removing  the  fittings  on  the 

inlet/outlet water pipes (side water); remove Thermostatic valve (see Fig.1); 

4)

 

Proceed with the cleaning by flushing the tubes with descaler anti-scale 

out in the opposite direction of the normal flow for about 30 minutes. Then 
flush them out with hot water in order to remove all the residues left; 

5)

 

Reassemble Thermostatic valve, the cooler and re-pipe the cooling 

circuits. 

 

NOTE

: Follow the local rules for the treatment and the disposal 

of  the  chemical  products  and  the  norms  for  the  protection  of  the 
environment. 

 

WARNING: In case of machine downtime during the winter 

period, drain the cooling water circuit (Fig.2) to prevent the formation 

of ice in the system.

 

7. LUBRICANTS 

 

See LI1586 

8. DE-COMMISSIONING 

 

See LI1586 

9. RETURN FOR REPAIR 

 

See LI1586 

10. TROUBLESHOOTING 

 

See LI1586

 

TROUBLE

 

CAUSE

 

REMEDY

 

Inefficient cooling 

Lack of water in the cooling circuit 

Check the circuit and the water supply 

Inefficient pump cooling circuit 
 

Check the correct operation of the pump cooling circuit (heat 
exchanger and pipes), if they are scaled, clean them (see 6.9). 

Lack of lubrication  

Check oil level and conditions (see 6.2). Top up the oil level or 
change it. Check if the oil filter is clogged. If necessary, replace 
it. 

Содержание EU W Series

Страница 1: ...UTENZIONE ADDENDUM OPERATING AND MAINTENANCE INSTRUCTIONS LI 5380 P0 06 2022 ITA ORIGINALE ENG TRANSLATION Serie EU W Pompe per vuoto lubrificate a palette raffreddamento ad acqua Water cooled lubrica...

Страница 2: ...3 5 INSTALLAZIONE E FUNZIONAMENTO Pag 3 5 1 Assemblaggio Pag 3 5 2 Modifica campo di lavoro Pag 3 5 3 Ubicazione Pag 3 5 4 Collegamento alla macchina utilizzatrice Pag 3 5 5 Convogliamento aria di sca...

Страница 3: ...nsigli per l utilizzo Vedi LI1586 5 9 Aspirazione vapor acqueo Vedi LI1586 5 10 Collegamento all impianto di raffreddamento Collegare l ingresso IN e l uscita OUT del circuito dell acqua utilizzando t...

Страница 4: ...6 9 Manutenzione circuito raffreddamento ATTENZIONE Eseguire gli interventi di manutenzione a macchina ferma ed ad una temperatura non pericolosa Per garantire il massimo rendimento dello scambiatore...

Страница 5: ...5 COMMISSIONING AND OPERATION Page 6 5 1 Assembling Page 6 5 2 Operating vacuum range changing Page 6 5 3 Location Page 6 5 4 Connection to the machine Page 6 5 5 Discharge air pipe line installation...

Страница 6: ...ng See LI1586 5 8 Suggestions for the use See LI1586 5 9 Water vapour suction See LI1586 5 10 Cooling system hook up Connect the inlet IN and the outlet OUT of the water circuit using pipes having the...

Страница 7: ...ater and oil Skilled Worker 6 9 How to service the cooling circuit WARNING Carry out the maintenance operations only with the pump not operating and at a safe temperature To guarantee the maximum perf...

Страница 8: ...18599 E mail info pvr it www pvr it La P V R declina ogni responsabilit per uso improprio o non conforme alle istruzioni fornite manomissione e manutenzione inadeguata della pompa P V R declines any r...

Отзывы: