![PVA PCP Series Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/pva/pcp-series/pcp-series_operation-manual_1628592024.webp)
PCP Series Manual
Revision A
/
September 2020
Page 24 of 46
3.
Lubricate the AN016 O-ring with pump conditioner.
4.
Install the AN016 O-ring onto the seal block.
Figure 22: Install O-Ring on Seal Block
5.
Install the fluid block onto the seal block/rotor assembly.
Figure 23: Install Fluid Block
Note: When installing the fluid block, ensure that the bleed port is on the front and
the fluid inlet is on the outer side of the pump. For example, in the left pump pictured
above, the fluid inlet is on the left side.
Bleed Port