Separate the seal block from the rotor assembly.
Figure 16: Remove Seal Block
Clean All Wetted Parts
•
Wear gloves when you use solvents.
•
Cover the work surface so the solvent and material does not damage it.
•
Only use appropriate solvents.
1.
Use solvent, cotton tipped applicators and lint free disposable towels to clean all
wetted parts of the pump. When cotton tipped applicators and towels get dirt and
material on them, discard them and use a new one. Do not mix the materials.
2.
Make sure all material is removed from the inside and outside.
3.
Clean the fluid port.
4.
Make sure all material is removed from the rotor and the groove at the base of the
rotor.
Figure 17: Clean Rotor
Note: Do not flush the rotor assembly with any material or put it in solvent as the
bearings may be damaged as a result. Clean only with cotton tipped applicators, a
cloth, and/or a soft brush.