FC100-CF Manual
Revision B
/
February 2022
Page 7 of 23
Safety
Due to material contents being under pressure eye protection is required for operators. Refer to MSDS sheets on material being dispensed for other precautions.
Страница 1: ...Film Coat Dispense Valve FC100 CF Operation Manual Revision B INNOVATION PRECISION EXCELLENCE ...
Страница 2: ...f this document with respect to changes subsequently made Precision Valve and Automation Inc makes no representation or warranty expressed implied or statutory with respect to and assumes no responsibility for the accuracy completeness sufficiency or usefulness of the information contained herein No warranties of merchantability or fitness for purpose shall apply This document including the inform...
Страница 3: ...formation 4 Document History 4 System Description 5 Nozzle Options 6 Tool Kit 9 Operation 10 Periodic Maintenance 10 Routine Cleaning and Disassembly 11 Assembly Instructions 13 General 13 Air Section 13 Fluid Section 14 Assemble Section 14 Spare Parts 15 Drawings 16 Bill of Materials 19 ...
Страница 4: ...x Corporate Drive Halfmoon NY 12065 Tel 1 518 371 2684 Fax 1 518 371 2688 Website http www pva net Email info pva net Technical Support Tel 1 844 734 0209 Email cs pva net Document History Revision Revision Date Reason for Changes B December 2021 Updated Bill of Materials and Drawings A Initial Release Note All photographs and CAD model representations in this document are a general representation...
Страница 5: ...ir body controls how far the piston and needle assembly can retract thus regulating the rate of fluid flow The micrometer will display a distance that the piston and needle will travel The fluid section is a stainless steel body which includes a needle and seat combination to control fluid flow Fluid dispenses as the needle retracts out of the seat then stops as the needle moves back into the seat...
Страница 6: ...es are selected based on the viscosity of the coating fluid and desired coating thickness PVA s application engineers can help you select the best nozzle for your valve Valves are supplied from the factory with one nozzle included Below is a chart showing the part numbers that are used to specify the nozzle that is supplied with a valve and the available orifices flow rates and fan widths for each...
Страница 7: ... Manual Revision B February 2022 Page 7 of 23 Safety Due to material contents being under pressure eye protection is required for operators Refer to MSDS sheets on material being dispensed for other precautions ...
Страница 8: ...n of the valve The port located furthest from the midsection of the valve is air to close the valve The port located closest to the mid section of the valve is air to open the valve Quick connect air fittings are typically supplied with the FC100 CF to fit 5 32 in tubing Note The valve should normally be in the closed position Fluid is supplied to the FC100 CF through the 1 8 in fnpt port located ...
Страница 9: ...y Part Number Description 2 0266244 8 in Adjustable Wrench 2 26563 3 32 in Allen Key 1 26561 5 64 in Allen Key 1 26559 1 16 in Allen Key 1 5516A18 Tweezers 1 B62 0752 2 5cc Mineral Oil Lubrication Kit 1 B62 2048 2 5cc Silicone Lubricant 1 9570K71 Hook and Pick Set 1 0266255 Pliers 2 53085A61 Soft Plastic Cover for Pliers 1 PB135 2 Micrometer Screw Driver 2 1 PT17184 Micrometer Adjustment Wrench 1 ...
Страница 10: ...luid connection and the packing nut 17 for leaks Note If the valve is leaking refer to the Troubleshooting section 7 Turn the micrometer adjustment head 6 until the desired flow rate is achieved Turning the adjustment clockwise toward zero will decrease the material flow rate and counterclockwise will increase the material flow rate If the micrometer adjustment is turned all the way down to zero i...
Страница 11: ...ull the air section red anodized portion away from the fluid section stainless steel portion 6 Clean off the tip of the stainless steel needle 2 7 From the fluid section of the valve unthread and remove the packing nut 17 and the packing 16 8 Using an adjustable wrench unthread and remove the nozzle cap 5 from the nozzle adapter 1 to remove the film coat nozzle 9 Remove the 006 Kalrez O ring 19 fr...
Страница 12: ...16 Hold the piston 14 with an adjustable wrench then using the 5 64 in Allen key unthread and remove the set screw 10 to remove the needle 2 and remove the 014 Buna O ring 21 from the piston 14 17 Remove the 014 Buna O ring 21 from the upper air body 3 then use a 1 16 in Allen key to remove the set screw 7 18 Using pliers grip the collar Figure 9 Part E or body Figure 9 Part D of the micrometer he...
Страница 13: ...d turn clockwise to snug it onto the upper air body 3 5 Use a 1 16 in Allen key to assemble the set screw 7 into the upper air section 3 securing the micrometer head 6 in place 6 Mount one 014 Buna O ring 21 on the end of the upper air body 3 7 Drop the needle 2 into the piston 14 and assemble with the set screw 10 using an adjustable wrench and 5 64 in Allen key to tighten 8 Mount the 014 Buna O ...
Страница 14: ...luid body 4 and tighten with an adjustable wrench 4 Place one 006 Kalrez O ring 19 into the groove of the nozzle adapter 1 5 Drop the film coat nozzle into the bottom groove of the nozzle cap 5 and thread the assembly onto the nozzle adapter 1 Assemble Section 1 Ensure the micrometer adjustment head 6 is backed out far enough so at least the number 1 can be seen on the gauge Figure 9 Part D 2 Appl...
Страница 15: ...placement of all wearable parts of the valve The spare parts kit for the FC100 CF product number FC1 C4 SP includes the following components Quantity Part Number Description 1 V302 Seat 1 114 5247 Needle 1 V305 Packing Teflon 2 VLV 014B O ring Buna 1 VLV 007B O ring Buna 2 VLV 006K O ring Kalrez 1 VLV 004B O ring Buna 1 PT17184 Micrometer Adjust Wrench Figure 4 FC1 C4 SP Spare Parts Kit ...
Страница 16: ...FC100 CF Manual Revision B February 2022 Page 16 of 23 Drawings Figure 5 FC100 CF Dimensions ...
Страница 17: ...FC100 CF Manual Revision B February 2022 Page 17 of 23 Figure 6 FC100 CF Flow Pattern Figure 7 FC100 CF Cross Section ...
Страница 18: ...FC100 CF Manual Revision B February 2022 Page 18 of 23 Figure 8 FC100 CF Cross Section Figure 9 Micrometer Adjustment Breakdown ...
Страница 19: ...e Cap 1 6 01423 Micrometer Head 1 7 01469 Set Screw 5 40 in x 3 16 in 1 8 SHCS 5 40 in x 1 in Socket Head Cap Screw 2 9 SHCS 5 40 in x 2 in Socket Head Cap Screw 2 10 V001 Set Screw 1 11 V050 Spring 1 12 V200 End Cap 1 13 V201 Lower Air Body 1 14 V202 Piston 1 15 V302 Seat 1 16 V305 Packing 1 17 V306 Packing Nut 1 18 VLV 004B O Ring 004 Buna N 1 19 VLV 006K O Ring 006 Kalrez 2 20 VLV 007B O Ring 0...
Страница 20: ...the parts as necessary Air bubble trapped in fluid body or in nozzle adapter Flip the valve upside down and cycle until the air bubbles are removed O ring is worn or missing the nozzle extension Replace the O ring Valve leaks from the mid section Packing nut is loose Tighten the packing nut until it is snug Packing is worn Replace the packing Valve does not dispense anything Fluid pressure is too ...
Страница 21: ...o close to the zero mark Turn the micrometer adjustment bolt counterclockwise away from the zero mark Fluid does not dispense uniformly from the nozzle Fluid pressure is too low Increase the fluid pressure until the fluid fans out in a wide pattern Material is cured on the nozzle tip Clean the tip with a cloth or solvent ...
Страница 22: ...warranties All PVA warranties extend only to the original purchaser Third party warranty claims will not be honored at any time Prior to returning a product for a warranty claim a return authorization must be obtained from PVA s Technical Support department Authorization will be issued either via the telephone facsimile or in writing upon your request To qualify as a valid warranty claim the defec...
Страница 23: ...zle Options 6 Figure 2 Solenoid Valve 8 Figure 3 B12 1986 Tool Kit 9 Figure 4 FC1 C4 SP Spare Parts Kit 15 Figure 5 FC100 CF Dimensions 16 Figure 6 FC100 CF Flow Pattern 17 Figure 7 FC100 CF Cross Section 17 Figure 8 FC100 CF Cross Section 18 Figure 9 Micrometer Adjustment Breakdown 18 ...