FC100-CF Manual
Revision B
/
February 2022
Page 12 of 23
Note: During removal, the spring (11) will force the air section apart.
13.
Separate the upper air body (
) to remove the spring
14.
Holding the lower air body (
) in one hand, grab the needle (
) and push the needle
and piston (
) assembly out of the lower air body.
15.
Remove the 004 Buna O-ring (
16.
Hold the piston (
) with an adjustable wrench then using the 5/64 in Allen key
unthread and remove the set screw (
) and remove the
014 Buna O-ring (
17.
Remove the 014 Buna O-ring (
) then use a 1/16 in
Allen key to remove the set screw (
18.
Using pliers grip the collar (Figure 9, Part E) or body (Figure 9, Part D) of the
micrometer head (
) and turn counterclockwise to loosen then unthread and
remove from the upper air body (
) by hand.
19.
Remove the 007 Buna O-ring (
20.
Replace components with spares provided in the spare parts kit shown in Figure 4.