P
USH
C
ORP,
I
NC.
AFD1000
Manual
Figure 2. AFD1000-1 and AFD1000-2 Mounting Brackets
Страница 1: ...AFD1000 Adjustable Force Device Manual April 2001 U S Patent No 5 448 146 PAR01640 1 PUSHCORP INC Dallas Texas...
Страница 2: ...st separator Non compliance with these requirements will void the manufacturer s warranty See Section 4 3 All fasteners mounting holes and pipe threads on this tool are METRIC All PushCorp Inc electri...
Страница 3: ...ent 5 4 2 Mounting the 1000 Series 6 4 2 1 Mounting the AFD1000 1 Vertical and AFD1000 2 Horizontal 6 4 2 2 Mounting the AFD1000 3 Table Top 8 4 3 Maximum Carriage Load Calculations 8 4 4 Pneumatic Co...
Страница 4: ...ARRANTIES INCLUDING THOSE OF MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE Some states do not allow limitations on how long an implie...
Страница 5: ...oduct as described in the owner s manual s When warrantor will perform repair or replacement under this warranty Repair or replacement will be scheduled and serviced according to the normal work flow...
Страница 6: ...t particles are created This Purge Port connection provides additional airflow and internal positive pressure to minimize contamination entering the AFD The Carriage has threaded mounting holes to pro...
Страница 7: ...o the Carriage extreme care should be taken while designing and installing the brackets Correctly designed brackets will increase the stiffness of the Carriage by becoming an external superstructure f...
Страница 8: ...eries force device allows attachment to a stationary fixture or a robotic manipulator mounting flange Specifying an AFD1000 1 2 or 3 determines which Mounting Bracket is supplied Adapter plates or qui...
Страница 9: ...PUSHCORP INC AFD1000 Manual Figure 2 AFD1000 1 and AFD1000 2 Mounting Brackets...
Страница 10: ...t these equations require the use of Metric units The necessary conversions are provided for your convenience Insert your maximum applied force and process equipment weight W and overhang distances D...
Страница 11: ...PUSHCORP INC AFD1000 Manual...
Страница 12: ...ce The pneumatic supply system should be configured as shown in the Figure 4 Figure 4 Pneumatic configuration If water condensation is a problem in your air supply system an air dryer device is highly...
Страница 13: ...ressed air and verify that there are no air leaks and that there is a minimum of 80 PSI 5 5 bar at the AFD If a minimum air pressure cannot be achieved then an auxiliary air compressor or booster pump...
Страница 14: ...t the factory for optimal performance and in general should not require field adjustment However there are situations that could arise that cause the Linear Rails to need adjustment Often a loose or t...
Страница 15: ...loosened You are now ready to continue on to preload the Carriage Linear Rails 2 To preload the Carriage Linear Rails loosen the Movable Linear Rail M6x1 Socket Head Cap Screws holding the Movable Lin...
Страница 16: ...ting the Preload Adjustment Set Screws Note that one of the Preload Adjustment Set Screws could require more adjustment than the other Do not over tighten the Preload Adjustment Set Screws Over tighte...
Страница 17: ...ensing Supply air Non lubricated Dry 5 m Filtered 80 90 psi 5 5 6 2 bar 2 SCFM 28 l min Specifications subject to change without notice These values are based on measurements taken in a laboratory env...
Страница 18: ...cause a loss in functionality as well as a decrease in product life PUSHCORP INC AFD Maintenance Weekly Monthly 3 Months Remove debris from AFD X Check that the connectors are not bent damaged X Check...