OS 335
35
BATTERY SWITCHES
There are four battery switches and two parallel switches to manage the 12-volt power distribution.
The Port Start switch controls the battery for the port engine. The Starboard Start switch controls the battery
for the starboard engine. The Parallel switch connects the port and starboard engine batteries for emergency
starting if one of the engine batteries is dead or low.
The Electronics switch provides power to the electronic buss bar that feeds aftermarket electronics
installations. The House switch provides power to the house circuits on the boat. If the Electronics or House
battery is dead or low, the Parallel switch can be used to connect the two batteries together.
For information on battery charging using the on-board charger, refer to Battery Charger in the AC Systems
section of this chapter.
THE BOAT SHOULD NOT BE OPERATED ON A CONTINUOUS BASIS WITH THE EMER-
GENCY PARALLEL SWITCH IN THE "ON" POSITION.
Make sure that all battery switches are activated whenever the engines are running to ensure that all 12-volt
accessories will operate when they are needed. Current is supplied to the automatic float switches for the
bilge pumps, high water bilge alarm and stereo memory when the batteries are connected and the
battery switches are off.
DISTRIBUTION BREAKERS
Helm Main
Supplies 12-volt electrical current to the breakers on the helm breaker panel.
DC Main
Supplies 12-volt electrical current to the cabin DC breaker panel.
Electronics Main
Reserved for electronics installations. Supplies buss bar located behind the helm.
Forward Bilge
The forward bilge pump breaker provides protection for the automatic float switch on the forward bilge pump.
Aft Bilge
The aft bilge pump breaker provides protection for the automatic float switch on the aft bilge pump.
Windlass (Optional)
Push the red button to open the circuit breaker. To reset or turn the circuit breaker on, rotate the black lever
to the "ON" position. Turning off this breaker when the windlass is not in use will reduce the possibility of
accidentally activating the windlass.
Engine Circuit Breakers
Circuit protection for the ignition switch and engine components is provided on the engine. Please refer to
Содержание OS 335
Страница 2: ...OS 335 2 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 4: ...OS 335 4 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 6: ...OS 335 6 OperatorNotes...
Страница 8: ...OS 335 8 OperatorNotes...
Страница 10: ...OS 335 10 OperatorNotes...
Страница 48: ...OS 335 48 OperatorNotes...
Страница 60: ...OS 335 60 OperatorNotes...
Страница 72: ...OS 335 72 OperatorNotes...
Страница 82: ...OS 335 82 OperatorNotes...
Страница 98: ...OS 335 98 OperatorNotes...
Страница 106: ...OS 335 106 OperatorNotes...
Страница 114: ...OS 335 114 OperatorNotes...
Страница 122: ...OS 335 122 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 124: ...OS 335 124 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Страница 125: ...OS 335 125 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Страница 126: ...OS 335 126 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Страница 127: ...OS 335 127 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Страница 128: ...OS 335 128 Hours Date Dealer Service Repairs MAINTENANCE LOG...
Страница 132: ...OS 335 132 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 136: ...OS 335 136 THIS PAGE WAS LEFT BLANK INTENTIONALLY...