5
2. CARACTERÍSTICAS TÉCNICAS
Application
Water Treatment
• Reverse osmosis (ROP Model)
• Filtration (F Model)
• Ultrafiltration (UF Model)
Use
•
Mejora de las características del agua potable (que cumpla con los requisitos
de la Directiva Europea sobre Agua de consumo humano 98/83 o sus trasposicio-
nes nacionales en los distintos estados miembros de la Comunidad Europea).
Modification for reduction or intake
ROP Model
• Water treatment through reverse osmosis is able to reduce the concentration of
salts and other substances in high percentages.
• Minimum reduction* of certain components and parameters:
Sodium – 90 %
Calcium – 90%
Sulphates – 90%
Chloride – 90%
Overall hardness – 90%
Conductivity – 90%
(*) Based on the characteristics of water to be treated (at the outlet of the membrane).
These values may vary depending on the type of post-filter used in the equipment.
F Model
• The treatment of water through filtration retains all suspended particles that have
a diameter larger than 5 microns.
• The carbon filter reduces* the flavour and smell of the water, as well as its
organic components.
(*) Based on the characteristics of the water to be treated.
UF Model
• This equipment comprises a first Filtration stage.
• The treatment of water through Ultrafiltration is able to retain suspended parti
cles that have a diameter between 0,1 and 0,0001 microns.
(*) Based on the characteristics of the water to be treated.
Opertional Limit
Technical
2. TECHNICAL CHARACTERISTICS
Pressure (max. / min.)
TDS (max.)
Temperature (max. / min.)
Hardness (max.)
Control Type:
Security System:
Inlet connection:
Drainage Connection:
Wall adapter:
Drain saddle:
ROP
2,5 bar (250 kPa) 1 bar
(100 kPa)
2000 ppm
40ºC – 2ºC
15ºHF**
Level switch.
Inlet Solenoid Valve.
Cold Water Thermostat.
Hot Water Thermostat.
Hot water security shield.
Anti-spill Float valves.
1/4”
1/4”
3/8”
40 mm clamp for the
drainage tube
Cold Water Thermostat.
Hot Water Thermostat.
Hot water security shield.
Anti-spill Float valves.
1/4”
-
3/8”
-
Cold Water Thermostat.
Hot Water Thermostat.
Hot water security shield.
Anti-spill Float valves.
1/4”
-
3/8”
-
F
5 bar (500 kPa) 1 bar
(100 kPa)
-
40ºC – 2ºC
-
UF
5 bar (500 kPa) 1 bar
(100 kPa)
-
40ºC – 2ºC
-
Содержание columbia aqua FC-1300-F
Страница 1: ...Technical Manual Service Booklet MT FC 1300 ROP FC 1300 F FC 1300 UF ...
Страница 2: ......
Страница 8: ...8 ELECTRIC SCHEME RO MODEL ELECTRIC SCHEME UF AND F MODELS ...
Страница 9: ...9 ROP MODEL HYDRAULIC CONNECTION SCHEME U AND UF MODELS HYDRAULIC CONNECTION SCHEME INLET INLET DRAIN ...
Страница 13: ...13 ...
Страница 18: ...18 10 NOTES ...
Страница 19: ...19 10 NOTES ...
Страница 20: ...MTFC1300ROPFUF2018 MT ...