NO FRILLS 500/800 Guides
Cleaning-valve
(mounted at the pressure regulation)
This valve enables, either a flow over board (Normal Flow), or a recirculation for cleaning and
preservation. (Cleaning Flow) See flow diagram.
Fresh-water
– flush system (FWS)
The fresh-water
– flush system provides flushing the system when not in use, with fresh
water, just with a turn of the handle at the selector valve. The build in changeable carbon
filter cartridge prevents that chloride exits the membrane. The handle must be installed below
the waterline if you install the system acc. Page 12. When installing acc. Page 12a all
components except the boost pump can be mounted over the waterline. Flushing the system
extends the lifetime of the membrane and is used for short time storage. (up to10 days)
7