9
WU-UV SERIES
| Filtration & Ultraviolet Disinfection All-in-One Unit
5.
Position the system on the wall. Insert and tighten the fixings to hold the system
securely to the wall. This unit can be installed from left to right or right to left
depending on the water supplies point of entry.
Note: The outlet is always on the UV side of the system.
6. Install the ballast using the two fasteners
supplied. This may be mounted in either direction
dependent on your point of entry and ease of use.
7. Turn the water off and purge the lines.
8. Plumb inlet and outlet pipe work to the WU-UV
unit. The inlet is a 25 mm female and the outlet is
a 25 mm male.
Note: Use thread seal tape, do not use liquid sealants. Never connect PVC pipe directly to
the unit. The outlet pipe work within 1 metre should be metal or polyethylene.
9. Check to the top aluminium nut has not been inadvertently
loosened during transport, retighten the nut. Insert the
spring into the chamber by dropping it into the quartz sleeve.
Slowly insert UV lamp into chamber through the hole of
the aluminium nut end. Connect the lamp connector to the
pins on the lamp. Do not let go of the lamp until the lamp is
connected to the socket (
see Fig. 4
).
Never touch the quartz (glass) and lamp surface as marks
or fingerprints may interfere with UV transmission. If lamp is
soiled, please clean lamp with an alcohol based cleaner.
10. Put safety cap on the aluminium nut end. Connect the ground
wire to the chamber as shown in Fig 5. Plug in power connector.
11. Check each housing bowl and ensure they have not become
loose in transport. Tighten the bowls with the supplied spanner
until firm. DO NOT OVER TIGHTEN.
12. Turn the water on, let the water flow through – opening a tap
downstream to flush the unit for 1-2 minutes. Then check the
system thoroughly for leaks.
Note: For initial use, wait 3-5 minutes to allow water to pass
through the whole unit. Turn on a downstream tap to let
water flow through the unit for 2-3 minutes to release air
and impurities from the system.
13. Turn the power on and ensure that the lamp is operating. Make sure that the GREEN
LED is illuminated (refer Lamp Replacement Procedure on pg.14).
Installation Procedure
1
2
valve
IN
OUT
4
5
Replacing UV Lamp
7
8
Replacing UV Lamp
IN
Fig. 5
DIMENSIONS ARE IN MILLIMETRES
DO NOT SCALE
0 +- 1.0mm
0.0 +- 0.5mm
0.00 +- 0.1mm
ANGLES:
DIMS.
0 +- 1.0deg.
A
B
C
D
E
F
G
H
12
12
11
11
10
10
9
9
8
8
7
7
6
6
A2
Fig. 3
Fig. 4
Содержание WU-UV Series