Puretec QT18 Скачать руководство пользователя страница 7

7

 

Quick Twist Undersink Water Filter System with High Loop LED Faucet

Performance Data

Performance Data

Substance

Guidelines*

Average 

Influent 

Concentration

Max Effluent 

Concentration

Min Percent 

Removal

Average 

Effluent 

Concentration

Average 
Percent 

Removal

NSF Standard 42 Drinking Water Treatment Units 

Chlorine 

(11,355 L)

5 - Health                  
0.6 - Aesthetic

2.1

0.3

50%

0.25

>94%

Standard 53 Cyst Live Cryptosporidium POU/POE

Cyst 

<1

100,000

ND (1)

99.98% +

ND (1)

99.99%

Test Parameters

Hardness, Total mg/L

120

TDS mg/L

290

Temp deg C

21°C

Turbidity NTU

0.1

pH

7.57

*Australian Drinking Water Guidelines - 1996

ND = Not Detected

This appliance meets the domestic water treatment appliance Standards AS/NZS3497 for the following 
water treatment processes:

Class

Treatment type

Function

Pass

I

Microbiological Status

Will stop bacteria increasing, but will not 
remove them unless II(a) is passed

N/A

Bacteriostatic

II

Microbiological Treatment

II (a)

Bacteria Removal

Will remove or inactivate bacteria

N/A

II (b)

Virus Removal

Will remove or inactivate virus

N/A

II (c)

Protozoa Removal

Will remove or inactivate Cryptosporidium 
and Giardia, but will not remove or 

inactivate bacteria and virises unless II(a) 
and II(b) is passed

YES

III

Turbidity & Particulate Reduction

Reduces cloudiness

YES

IV

Taste & Odour Reduction

Reduces taste & odours

YES

V

Chemical Treatment

Decreases chlorine

YES

Содержание QT18

Страница 1: ...3497 Licence No WM 74726 Australian Certification Services User Guide Quick Twist Undersink Water Filter System QT18 For correct operation installation it is essential to observe these instructions M...

Страница 2: ...efore or after the system Operation The Puretec QT18 system is designed to run economically for many years and this is dependant on the initial installation and periodical maintenance Flush systems fo...

Страница 3: ...water line and connect the Smart Tee Reinstall the previous connection to the tee valve 3 Connect the pressure limiting multivalve to the Smart Tee with a length of white tubing 4 Choose the best posi...

Страница 4: ...if any before leaving the unit After installing cartridges flush unit for 5 10 minutes Use Guidelines Minimum operating pressure 100 kPa Maximum operating pressure 875 kPa Do not allow exposure to tem...

Страница 5: ...collet against body and slide tube out of fitting 2 Fitting grips before it seals Ensure tube is pushed in to tube stop HOW TO USE QUICK CONNECT FITTINGS 3 Tube is secured in position Figure 2 Figure...

Страница 6: ...eat assembly into the faucet lever Important note Battery must be replaced when changing cartridges 5 Red light flashes indicates your cartridges are due to be changed usage has exceeded 3 000 minutes...

Страница 7: ...elines 1996 ND Not Detected This appliance meets the domestic water treatment appliance Standards AS NZS3497 for the following water treatment processes Class Treatment type Function Pass I Microbiolo...

Страница 8: ...no circumstance be held liable for damages consequential or otherwise or delays caused or faulty manufacturing except as excluded by law Applicable to all above is that the Warranties need to be appro...

Отзывы: