Installation Guide

9.  Restore the water supply and check for leaks. 

10.  Run the system for at least 5 minutes to remove carbon fines. Water may appear 

milky, but this is normal and is only tiny air bubbles that will clear after a short period.

Cartridge Installation/Changeout

1.  Place container under filter in case of drips.

2.  Twist out old cartridge. Discard old cartridge.

3.  Remove packaging from the new cartridge including the yellow cap on top of the 

cartridge. Twist in the new cartridge. Ensure firm seal to head.

 

Replacement cartridge code: 

Puretec

 

QT12R

4.  Reset LED indicator by following instructions on page 6. 

5.   Restore water supply.

6.  Check for leaks, rectifying them, if any, before leaving the unit.

 

After installing cartridges flush unit for 5 - 10 minutes.

Use Guidelines

• 

Minimum operating pressure 100 kPa.

• 

Maximum operating pressure 875 kPa.

• 

Do not allow exposure to temperatures below 3°C.

• 

Maximum operating temperature 38°C.

• 

Maximum flow rate 5 Lpm.

• 

This system must be installed according to local plumbing codes on the cold water line 
- mains only.

• 

Replacement Cartridges: See Cartridge Changeout section

• 

This system requires regular replacement of the filter cartridge to maintain proper 
operation. Varying chlorine, sediment, or organic substance levels may affect 
replacement frequency.

• 

Be sure to change the filter cartridge at least every 11,355 litres or 6 months which 
ever occurs first; or whenever you detect a change in taste, odour, or decrease in flow. 

 

Caution

: Do not use with water that is microbiologically unsafe or of unknown quality 

without adequate disinfection before or after the system.

Содержание QT18

Страница 1: ...3497 Licence No WM 74726 Australian Certification Services User Guide Quick Twist Undersink Water Filter System QT18 For correct operation installation it is essential to observe these instructions M...

Страница 2: ...efore or after the system Operation The Puretec QT18 system is designed to run economically for many years and this is dependant on the initial installation and periodical maintenance Flush systems fo...

Страница 3: ...water line and connect the Smart Tee Reinstall the previous connection to the tee valve 3 Connect the pressure limiting multivalve to the Smart Tee with a length of white tubing 4 Choose the best posi...

Страница 4: ...if any before leaving the unit After installing cartridges flush unit for 5 10 minutes Use Guidelines Minimum operating pressure 100 kPa Maximum operating pressure 875 kPa Do not allow exposure to tem...

Страница 5: ...collet against body and slide tube out of fitting 2 Fitting grips before it seals Ensure tube is pushed in to tube stop HOW TO USE QUICK CONNECT FITTINGS 3 Tube is secured in position Figure 2 Figure...

Страница 6: ...eat assembly into the faucet lever Important note Battery must be replaced when changing cartridges 5 Red light flashes indicates your cartridges are due to be changed usage has exceeded 3 000 minutes...

Страница 7: ...elines 1996 ND Not Detected This appliance meets the domestic water treatment appliance Standards AS NZS3497 for the following water treatment processes Class Treatment type Function Pass I Microbiolo...

Страница 8: ...no circumstance be held liable for damages consequential or otherwise or delays caused or faulty manufacturing except as excluded by law Applicable to all above is that the Warranties need to be appro...

Отзывы: