background image

TROUBLESHOOTING TIPS

The following is a troubling shooting guide to help you solve any issues that may have with the operation of the  PM 805.

Trouble

Possible reasons

Solution

Power icon is off or does not
work.

Humidifier is not plugged into the power 
outlet.

Connect power cord to electrical outlet and press 
power button.

Power light is on but no mist

No water in water tank.

Fill water tank with water.

The mist has a strange odour.

A new machine.

Remove the water tank, unscrew the lid and let it air 
out in a cool area for 12 hours.

It either has dirty water or the
water has been stagnant too
long.

Clean the water tank and refill with clean water.

Power  light  is  on,  but  the machine 
doesn’t work.

Too much water in the water basin.

Remove  the  water  tank.  Take  a small  cup  and 
remove some of the water from the machine’s water 
basin. Reinsert the water tank and make sure that it 
sits properly.

The volume of spray mist is too low.

Too much mineral scale in the
water basin.

Clean transducer.

Water is too dirty or water was kept too 
long in the tank.

Clean the water tank and refill with clean water.

Abnormal noise

Vibration in the water tank because the 
water level is too low.

Fill the water tank.

Machine is on an unstable surface.

Move the unit to a stable flat surface.

Spray mist is coming out of the area 
around the jets.

There  are  gaps  between  the housing 
around  jet  nozzles  and the  top  of  the 
water tank.

Dip  the  nozzle  in  water  for  a  while,  clean  it  with  a 
damp cloth and put it back to the tank.

The following is not considered faulty operation:

1.

If your water is very hard (containing abnormally high levels of minerals)  the humidifier may produce white dust. This is not a 

malfunction. The solution would be to clean the filter more often or use softer water.

2.

If you stand very close to the humidifier, you will hear the gurgling sound of water. This is normal.

                                                   

 

PUREMATE

English   6

Содержание PM 805

Страница 1: ...FIER WITH IONISER AND AROMA FUNCTION IMPORTANT DO NOT USE ESSENTIAL OILS DIRECT INTO WATER TANK THIS WILL CAUSE THE HUMIDIFIER TO MALFUNCTION AND RESULT IN WARRANTY BEING VOID DO NOT USE ANY OILS WARN...

Страница 2: ...t the cord under rugs near heat registers radiator stoves or heaters Do not attempt to refill humidifier without first unplugging the unit from its electrical outlet DO NOT operate any appliance with...

Страница 3: ...Air Outlet Transducer Buoy Indicator Lamp Touch Button Nozzle 2 TOUCH BUTTON ON OFF HEATING ION NOTE Sleeping Mode Press and hold the ON OFF button for 3 seconds the machine will enter into Sleeping...

Страница 4: ...be warmer as compared to the room tempera ture due to health and safety issues The warm mist light indicator is on and if you place your hand over the top outlet you may feel the warm mist INSTRUCTION...

Страница 5: ...e surface of the transducer 3 Rinse the transducer with clean water 4 Never use sharp or solid objects for cleaning the transducer How to clean the water basin 1 Clean the water with a soft damp cloth...

Страница 6: ...the water tank and make sure that it sits properly The volume of spray mist is too low Too much mineral scale in the water basin Clean transducer Water is too dirty or water was kept too long in the t...

Страница 7: ...services WHAT YOU MUST DO 1 Contact PureMate customer Service at 44 121 270 9423 www PureMate co uk for Return Authorization Number 2 Pack the product in its original carton and in the same manner in...

Страница 8: ...er Components 1 Front View 4 Remove Top Cover 5 Lifting Water Tank 6 Unscrew Tank Lid Cap 7 Filling Water Tank 8 Screw Tank Lid Cap 9 Placing Water Tank on Machine 3 Cleaning Transducer HELPFUL TIPS P...