PUREGLOW XPG170 Скачать руководство пользователя страница 2

 

YOUR FIRE 

XPG fires are visual effect fires with LED lighting and remote control. They are available 

with several different fascia trims and frets. 
The general fitting instructions refer to all models. 

 

SECTION 1: UNPACKING, ELECTRICAL INSTALLATION AND 

GENERAL SAFETY 

 

GENERAL 

Unpack the fire carefully and retain the packaging for possible future use, for example in 

the  event  of  moving  home  or  returning  the  fire  for  repair  to  your  supplier.  Remove  any 

plastic protection film and transit tape.  
The  fire  incorporates  an  effect  which  can  be  used  with  or  without  heating  so  that  the 

comforting  effect  may  be  enjoyed  at  any  time  of  the  year;  using  the  flame  effect  only 

requires minimal electricity. 
Before connecting the heater check that the supply voltage is the same as that stated on 

the heater. 
Please  note:  When  used  in  a  very  quiet  environment,  where  background  noise  is  very 

low,  it  may  be  possible  to  hear  a  sound  which  is  related  to  the  operation  of  the  visual 

effect; this is normal and should not be a cause for concern. 

 

ELECTRICAL INSTALLATION 

THIS APPLIANCE MUST BE EARTHED 

 

Check that the voltage stamped on the rating label of your fire is the same as your house 

electricity supply which must be AC (alternating current). 

The mains cord of the fire has a UK type plug fitted with a 13amp fuse. When replacing a 

fuse, use a 13amp fuse approved to BS 1362. The fuse cover of a moulded on plug must 

be refitted when changing the fuse; should it be lost the plug must not be used until the 

correct  replacement  fuse  cover  is  obtained  from  your  service  agent  or  the  plug  is 

replaced. 

 

The wires in the mains supply cord are coloured in accordance with the following code: 

Green and Yellow = Earth,   Blue = Neutral,   Brown = Live. 

 

If  your  fire  is  fitted  with  a  moulded  on  mains  plug  which  is  not  suitable  for  the  socket 

outlets in your home, the plug must be cut off and an appropriate one fitted.  

 

Note: A plug cut off from a flexible cord will give a shock hazard if inserted in a 13 amp 

socket elsewhere in the house. To avoid this it should be disposed of immediately. 

 

If you are fitting an alternative type of plug then the colours of the wires in the mains cord 

may  not  correspond  with  the  identifying  markings  on  the  plug  terminals.  In  this  case 

proceed as follows: 

 

The wire  which is coloured Green/Yellow must be connected to the terminal in the plug 

which  is  marked  by  the  letter  E  or  by  the  earth  symbol  or  coloured  Green  or  Green/

Yellow.  The  wire  which  is  coloured  Blue  must  be  connected  to  the  terminal  in  the  plug 

which is marked by the letter N or coloured Black. The wire which is coloured Brown must  

be connected to the terminal in the plug which is marked by the letter L or coloured Red. 
 

All Fires must be connected to a readily accessible isolating socket regardless of 

whether  they  are  free  standing  or  fixed  into  a  surround;  fixed  installations  must 

also be fused.

 

Содержание XPG170

Страница 1: ...EGLOW LIMITED This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given...

Страница 2: ...fuse approved to BS 1362 The fuse cover of a moulded on plug must be refitted when changing the fuse should it be lost the plug must not be used until the correct replacement fuse cover is obtained f...

Страница 3: ...to assist removal FIREPLACE INSTALLATION THIS FIRE MUST BE INSTALLED IN A FIREPLACE OPENING AND SECURED USING APPROPRIATE WALL FIXINGS Your PUREGLOW fire is designed to fit a standard 16 410mm firepl...

Страница 4: ...he membrane pad situated next to the thermostat With the mains supply con nected to the fire and switched on the fire can be operated By pressing the ON OFF FUNCTION button the features of the fire ca...

Страница 5: ...sh For difficult to remove marks such as finger marks it is recommended that a slightly damp chamois leather is used Care should be taken when cleaning around metal parts non painted metal parts may h...

Страница 6: ...Should this occur follow the points below 1 Switch the fire off at the wall outlet 2 Ensure that there are no obstructions in or around the air inlet see Fig 1 3 After approximately 5 minutes switch...

Страница 7: ...Fig 4 the ashpan and fuel bed can now be fitted see Section 6 for fuel bed layout ANNABELLE CHLOE JULIET CASTINGS The casting complete with magnets is positioned as shown in Fig 5 below and moved towa...

Страница 8: ...has been fitted or if the Fire was supplied with the Canopy fitted the Fire back should be fitted to the Fireplace using suitable fixings Double sided tape or Silicon sealant should be used if fitted...

Страница 9: ...if the fire is NOT fixed into the fireplace FITTING THE FRET The fret is fitted as shown on the diagram right care should be taken when positioning the fret to make sure that the fireplace hearth is n...

Страница 10: ...e the transit tape which holds the Fuel bed and back panel in place during transit and fitting The Log bed is also supplied with loose logs that are laid out after the above is complete see Log bed as...

Страница 11: ...11 LOG BED...

Страница 12: ...o the coal bed and are not intended to be removed individually 3 Loosen fuel bed locater screws allowing tabs to rotate down 4 Remove the fuel bed 5 Bend rear panel location tabs forward to release th...

Страница 13: ...USED AS SHOWN ABOVE WITH THE STABILITY BRACKET INSTALLED WHERE POSSIBLE THE FIRE SHOULD BE INSTALLED AS SHOWN BELOW USING THE WALL HANGER BRACKET THE WALL HANGER BRACKET SHOULD BE FIXED TO THE WALL U...

Страница 14: ...commercial waste at the end of its working life The Waste of Electrical and Electronic Equipment WEEE Directive 2002 96 EC has been put in place to recycle products using best available recovery and r...

Страница 15: ...sted Please do not send a photocopy Pure Glow Limited are not responsible for any cost incurred by the customer in returning the product to the seller When making a claim under warranty you must provi...

Страница 16: ...art No I01448 issue A Packing list Model Type Pureglow XPG 2kW Mains Lead Batteries Remote Handset Packed By Affix Second Data Label HERE Date Log bed Logs x4 Coal bed Back panel brick reed Packed By...

Отзывы: