Important Notes
Appliance Data
Installation Requirements
Site Requirements
Debris Collection Space
Ventilation
Pre Fabricated Flue Boxes
Unpacking the Appliance
Component Checklist
Preparing the Appliance 
Fitting the Decorative Frame
Preparing the Opening
Gas Supply Routing
Fitting the Firebox

Installation by Cable Fixing Kit

Page No.

1
2
2
3
4
4
4
4
5
5
6
6
6
7
7

Section

11.2

12.0
13.0

13.1

13.2
14.0

14.1

14.2
14.3
14.4
14.5
14.6
15.0
16.0

17.0

Contents

Fitting the Burner Tray
Fuel Bed Layout

Replacing The Battery (Slide Control Models)

Fitting the Firefront / Frame
Gas Connection
Testing and Commissioning

Operating the Appliance (Manual Control Models)

Operating the Appliance (Slide Control Models)
Spark Failure
Setting Pressure
Flue Spillage Monitoring System
Testing for Spillage
Briefing the customer
Servicing
Troubleshooting Guide

Page No.

7
8
8
8
8
8
8
8
8
8
9
9
9
9

11

1.0

I N S T A L L A T I O N   I N S T R U C T I O N S

IMPORTANT NOTES

This fire is an Inset Live Fuel Effect Gas Fire providing radiant warmth. It is designed to operate on Natural Gas
only.

It is the LAW that all gas appliances and fittings are installed by a competent

[1]

person and in accordance with the

Gas Safety (Installation and Use) Regulations 1998, the relevant British Standards for Installation, Codes of
Practice and in accordance with the Manufacturers’ Instructions. The installation shall also be carried out in accor-
dance with the following :

•  Manufacturers' Instructions.
•  The Building Regulations issued by the Department for Communities and Local Government, the Building Standards 

(Scotland) (Consolidation) Regulations issued by the Scottish Development Department.

•  Relevant British standards :
•  BS 5871 part 2
•  BS 5440 part 1, part 2
•  BS 1251
•  BS 6891
•  BS 6461 part 1
•  BS EN 1806
•  BS EN 1856 part 1
•  BS EN 1858
•  For Republic of Ireland, reference should be made to the relevant standards governing installation, particular-

ly in regard to flue sizing and ventilation. See IS813, ICP3, IS327 and any other relevant rules in force.

Failure to comply with the above could lead to prosecution and deem the warranty invalid.

This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated
space.

Consult all instructions before installation and use of this appliance.

This appliance is free from any asbestos material. Refractories and fuel bed are constructed from ceramic fibre.

1

[1] GB - Gas Safe

TM

registered operatives (Northern Ireland only- CORGI registered operatives) are the only class of person considered as competent by the HSE under the Gas Safety

(Installation and Use) Regulations 1998.

© 2009 Pure Glow Limited 

Содержание ANNABELLE

Страница 1: ...C 11 09 Country s of destination GB IE FULL DEPTH RADIANT GAS FIRE FOR USE WITH CHLOE JULIET NEW WAVE HEAT WAVE MEDIA CHURCHILL ANNABELLE ZARA CARMEN CARMEN HIW Pure Glow Limited Stourvale Road Lye St...

Страница 2: ...he appliance is designed for installation on to a non combustible hearth of at least 300mm depth This appliance is factory set for operation on the gas type and at the pres sure stated on the applianc...

Страница 3: ...ce with the Gas Safety Installation and Use Regulations 1998 the relevant British Standards for Installation Codes of Practice and in accordance with the Manufacturers Instructions The installation sh...

Страница 4: ...is installed into and the one venting the gases into the air A suitable terminal may be fitted such as class GC1 as regulations allow This appliance has been tested for use in a pre cast block flue co...

Страница 5: ...e back of the appliance must have a 50mm mini mum clearance between it and the back wall of the opening or any other obstruction The area immediately above the outlet must form a smooth path into the...

Страница 6: ...BRICATED FLUE BOXES This appliance can be fitted into a number of proprietary flue boxes provided that the minimum dimensions given in the diagram below are complied with Constructional Note The frame...

Страница 7: ...rebox on it s back Lay the tapered panel onto the rear face of the firebox The side panels should be fitted by inserting their front edges into the pre fitted retaining brackets on the front face of t...

Страница 8: ...is good Angle the firebox or adjust the spigot outlet as described in the Fitting the Firebox section Ensure that it slides in correctly the sealing face sits flat and square to the wall or infill pan...

Страница 9: ...should be posi tioned as close to the correct layout as possible Before finally fitting cables ensure the self adhesive sealing strips are in position on the back of the appliance frame The fireframe...

Страница 10: ...control knob in slightly and continue turning anti clockwise to the high position The main burner should light after a few seconds To decrease the setting to LOW turn the control knob clockwise to the...

Страница 11: ...highest setting and any communicating doors open Finally repeat with all doors open DO NOT allow the fire to be used until the test is satisfactorily passed BRIEFING THE CUSTOMER All instructions mus...

Страница 12: ...ing leg and lift assembly clear The injector pipe can now be checked for debris Remove the nut retaining the injector elbow Blow through the elbow to remove any debris The valve is not field serviceab...

Страница 13: ...me and then cuts off Excessive room draught or flue pull rectify Loose or faulty thermocouple rectify ODS system in operation Firebox grommet seal not fitted rectify Lint in pilot aeration hole clean...

Страница 14: ...his fire the coals or pebbles must be of the correct type and laid out in accordance with the relevant section of these instructions Failure to do so could create a hazard or lead to soot ing Before t...

Страница 15: ...ge test must be taken into consideration when assessing ventilation requirements this will have been car ried out by your registered installer For Republic of Ireland ventilation may be required see I...

Страница 16: ...he second row of coals in order to complete the third row The coals may be orien tated as desired to achieve a realistic effect Keep the spacing between the coals even and uniform The two coals at the...

Страница 17: ...orts The fuel bed layout is now complete The fire is designed to operate correctly with the pebbles supplied when assembled according to the instructions Never add to the six teen pebbles or change th...

Страница 18: ...ld be the problem and removal of the draught should resolve this The fire can then be re lit in accordance with the previous section A grommet seal may also be missing from the firebox causing abnorma...

Страница 19: ......

Отзывы: