PUREGLOW ANNABELLE Скачать руководство пользователя страница 16

FUEL BED LAYOUT (continued)

3. Open the bag of 16 moulded coals. All of the coals are the same.
Take five coals and place them as shown. Care should be taken to
ensure that the coals bridge the gap between the front coal and the
four coal supports at the front of the matrix. Care should also be
taken not to push the coals right  down between the coal supports,
as this can detract from the flame picture when the appliance is run-
ning. 

4. Take five more moulded coals and position as shown to form the
‘second row’ of the fuel effect. The coals may be rotated as desired
to fit into the  gaps between the coal supports in order to create a
random, realistic effect. Again, remember not to push the coals
down too far into the valleys between the coal supports as this can
have a detrimental effect to the flame picture.

5. Now take another four coals and place behind the second row of
coals, in order to complete the third row. The coals may be orien-
tated as desired to achieve a realistic effect. Keep the spacing
between the coals even and uniform. The two coals at the ends of
the row may be placed rearwards, towards the back corners of the
fuel matrix.

6. Finally, take the two remaining coals and place at the back of the
fuel matrix, in the centre as shown. Adding these coals should com-
plete the appearance of the fuel bed giving an even distribution of
equally spaced coals.

The fire is designed to operate correctly with the coals supplied
when assembled according to the instructions. Never add to the six-
teen coals, or change them for a different type. Never throw rubbish
or other matter onto the coal bed.

FUEL BED LAYOUT 
(pebble effect option)

1. Refer back to section 5.0 - Fuel bed layout (coal effect option) and
follow steps 1 and 2. The front strip and fuel effect matrix used for
pebble effect versions are of the same design as coal effect versions,
but have a different surface finish.

3

5.1

5.0

© 2009 Pure Glow Limited 

Содержание ANNABELLE

Страница 1: ...C 11 09 Country s of destination GB IE FULL DEPTH RADIANT GAS FIRE FOR USE WITH CHLOE JULIET NEW WAVE HEAT WAVE MEDIA CHURCHILL ANNABELLE ZARA CARMEN CARMEN HIW Pure Glow Limited Stourvale Road Lye St...

Страница 2: ...he appliance is designed for installation on to a non combustible hearth of at least 300mm depth This appliance is factory set for operation on the gas type and at the pres sure stated on the applianc...

Страница 3: ...ce with the Gas Safety Installation and Use Regulations 1998 the relevant British Standards for Installation Codes of Practice and in accordance with the Manufacturers Instructions The installation sh...

Страница 4: ...is installed into and the one venting the gases into the air A suitable terminal may be fitted such as class GC1 as regulations allow This appliance has been tested for use in a pre cast block flue co...

Страница 5: ...e back of the appliance must have a 50mm mini mum clearance between it and the back wall of the opening or any other obstruction The area immediately above the outlet must form a smooth path into the...

Страница 6: ...BRICATED FLUE BOXES This appliance can be fitted into a number of proprietary flue boxes provided that the minimum dimensions given in the diagram below are complied with Constructional Note The frame...

Страница 7: ...rebox on it s back Lay the tapered panel onto the rear face of the firebox The side panels should be fitted by inserting their front edges into the pre fitted retaining brackets on the front face of t...

Страница 8: ...is good Angle the firebox or adjust the spigot outlet as described in the Fitting the Firebox section Ensure that it slides in correctly the sealing face sits flat and square to the wall or infill pan...

Страница 9: ...should be posi tioned as close to the correct layout as possible Before finally fitting cables ensure the self adhesive sealing strips are in position on the back of the appliance frame The fireframe...

Страница 10: ...control knob in slightly and continue turning anti clockwise to the high position The main burner should light after a few seconds To decrease the setting to LOW turn the control knob clockwise to the...

Страница 11: ...highest setting and any communicating doors open Finally repeat with all doors open DO NOT allow the fire to be used until the test is satisfactorily passed BRIEFING THE CUSTOMER All instructions mus...

Страница 12: ...ing leg and lift assembly clear The injector pipe can now be checked for debris Remove the nut retaining the injector elbow Blow through the elbow to remove any debris The valve is not field serviceab...

Страница 13: ...me and then cuts off Excessive room draught or flue pull rectify Loose or faulty thermocouple rectify ODS system in operation Firebox grommet seal not fitted rectify Lint in pilot aeration hole clean...

Страница 14: ...his fire the coals or pebbles must be of the correct type and laid out in accordance with the relevant section of these instructions Failure to do so could create a hazard or lead to soot ing Before t...

Страница 15: ...ge test must be taken into consideration when assessing ventilation requirements this will have been car ried out by your registered installer For Republic of Ireland ventilation may be required see I...

Страница 16: ...he second row of coals in order to complete the third row The coals may be orien tated as desired to achieve a realistic effect Keep the spacing between the coals even and uniform The two coals at the...

Страница 17: ...orts The fuel bed layout is now complete The fire is designed to operate correctly with the pebbles supplied when assembled according to the instructions Never add to the six teen pebbles or change th...

Страница 18: ...ld be the problem and removal of the draught should resolve this The fire can then be re lit in accordance with the previous section A grommet seal may also be missing from the firebox causing abnorma...

Страница 19: ......

Отзывы: