Preliminary Notes Before Installation
This appliance is an Inset Live Fuel
Effect appliance that provides radiant
warmth utilising the latest type burn-
er technology.

The fire is designed to fit various
types of fireplaces and natural
draught flues as listed in the
Installation Requirements.

The appliance must be installed by a
competent

[1]

person in accordance

with Gas Safety (Installation and Use)
Regulations 1998. It is strongly rec-
ommended that a registered engineer be used for
this purpose.

Read all these instructions before commencing installation.
This appliance must be installed in accordance with the rules in force and
only used in a sufficiently ventilated space.
The appliance is designed for installation on to a non-combustible hearth of
at least 300mm depth.

This appliance is factory set for operation on the gas type, and at the pres-
sure stated on the appliance data plate.

The firefronts supplied with this appliance are available in a range of finishes.

Chloe 

Juliet 

Churchill

Heat wave

New wave

Media

Zara

Annabelle

[1] GB - Gas Safe

TM

registered operatives (Northern Ireland only- CORGI registered operatives) are the only class of person considered as competent by the HSE under the Gas Safety

(Installation and Use) Regulations 1998.

© 2009 Pure Glow Limited 

Please note : Except where otherwise stated, all rights, including copyright in the text, images and layout of this booklet is
owned by Pure Glow Limited.  You are not permitted to copy or adapt any of the content without the prior written permis-
sion of Pure Glow Limited.

Carmen

Carmen HIW

Содержание ANNABELLE

Страница 1: ...C 11 09 Country s of destination GB IE FULL DEPTH RADIANT GAS FIRE FOR USE WITH CHLOE JULIET NEW WAVE HEAT WAVE MEDIA CHURCHILL ANNABELLE ZARA CARMEN CARMEN HIW Pure Glow Limited Stourvale Road Lye St...

Страница 2: ...he appliance is designed for installation on to a non combustible hearth of at least 300mm depth This appliance is factory set for operation on the gas type and at the pres sure stated on the applianc...

Страница 3: ...ce with the Gas Safety Installation and Use Regulations 1998 the relevant British Standards for Installation Codes of Practice and in accordance with the Manufacturers Instructions The installation sh...

Страница 4: ...is installed into and the one venting the gases into the air A suitable terminal may be fitted such as class GC1 as regulations allow This appliance has been tested for use in a pre cast block flue co...

Страница 5: ...e back of the appliance must have a 50mm mini mum clearance between it and the back wall of the opening or any other obstruction The area immediately above the outlet must form a smooth path into the...

Страница 6: ...BRICATED FLUE BOXES This appliance can be fitted into a number of proprietary flue boxes provided that the minimum dimensions given in the diagram below are complied with Constructional Note The frame...

Страница 7: ...rebox on it s back Lay the tapered panel onto the rear face of the firebox The side panels should be fitted by inserting their front edges into the pre fitted retaining brackets on the front face of t...

Страница 8: ...is good Angle the firebox or adjust the spigot outlet as described in the Fitting the Firebox section Ensure that it slides in correctly the sealing face sits flat and square to the wall or infill pan...

Страница 9: ...should be posi tioned as close to the correct layout as possible Before finally fitting cables ensure the self adhesive sealing strips are in position on the back of the appliance frame The fireframe...

Страница 10: ...control knob in slightly and continue turning anti clockwise to the high position The main burner should light after a few seconds To decrease the setting to LOW turn the control knob clockwise to the...

Страница 11: ...highest setting and any communicating doors open Finally repeat with all doors open DO NOT allow the fire to be used until the test is satisfactorily passed BRIEFING THE CUSTOMER All instructions mus...

Страница 12: ...ing leg and lift assembly clear The injector pipe can now be checked for debris Remove the nut retaining the injector elbow Blow through the elbow to remove any debris The valve is not field serviceab...

Страница 13: ...me and then cuts off Excessive room draught or flue pull rectify Loose or faulty thermocouple rectify ODS system in operation Firebox grommet seal not fitted rectify Lint in pilot aeration hole clean...

Страница 14: ...his fire the coals or pebbles must be of the correct type and laid out in accordance with the relevant section of these instructions Failure to do so could create a hazard or lead to soot ing Before t...

Страница 15: ...ge test must be taken into consideration when assessing ventilation requirements this will have been car ried out by your registered installer For Republic of Ireland ventilation may be required see I...

Страница 16: ...he second row of coals in order to complete the third row The coals may be orien tated as desired to achieve a realistic effect Keep the spacing between the coals even and uniform The two coals at the...

Страница 17: ...orts The fuel bed layout is now complete The fire is designed to operate correctly with the pebbles supplied when assembled according to the instructions Never add to the six teen pebbles or change th...

Страница 18: ...ld be the problem and removal of the draught should resolve this The fire can then be re lit in accordance with the previous section A grommet seal may also be missing from the firebox causing abnorma...

Страница 19: ......