PUREGAS, LLC
P200W Series Dehydrator User’s Guide
Page 34 of 82
P012026 – Rev. F
8.4.5.2
PRESSURE Screen
PRESSURE
– Current pressure of the system (will fluctuate between the
Set Low Pressure and Set High Pressure values).
HUMIDITY
– Humidity level of the Dehydrator.
CAB TEMP
– Temperature of the Dehydrator cabinet compartment.
DUTY CYCLE
– The percentage of time the compressor is ON versus
time it is OFF in a given period of time.
8.5 Identifying Dehydrator Alarms
8.5.1
High Pressure Alarm -
Occurs when the
PRESSURE
rises above the alarm set point
for more than one (1) minute.
(Default setting is 3.00 PSI)
See Section 11.5 for troubleshooting information.
8.5.2
Low Pressure Alarm -
Occurs when the
PRESSURE
drops below the alarm set point
for more than one (1) minute.
(Default setting is 0.15 PSI)
See Section 11.7 for troubleshooting information.