For future reference, write down the model, serial number, and date of purchase for your
dehumidifier.
This is extremely helpful if you need to seek assistance in the future. The data label on the
side of your unit has the key characteristics of your specific unit.
The Sentinel Series Dehumidifiers utilizes its integral humidistat to monitor the conditioned
space.When the relative humidity goes above the selected set point, the dehumidifier will
energize. Air is drawn across an evaporator coil, which is cooler than the dew point of air.
This means moisture will condense out of the air. The air is then reheated through the
condenser coil and distributed back into the room.
For aditional questions concerming your dehumildifer, the following options
are available:
Contact your installing contractor
E-mail; [email protected]
MODEL NUMBER:
SERIAL NUMBER:
DATE OF PURCHASE:
POWER SUPPLY:
OUTLET REQUIREMENT:
CIRCUIT PROTECTOR:
240 Volts AC may cause serious injury from electric shock.
WARNING
TO REDUCE RISK OF INJURY:
1. Disconnect electrical power before servicing
2. Only plug unit into grounded electrical circuit
3. Do not use an extension cord.
4. Do not use a plug adapter
WARRANTY REGISTRATION
SAFETY NOTES
Congratulations on purchasing a new Sentinel Dehumidifier. Your new dehumidifier
comes with an extensive warranty plan. To register, simply fill out and return the
warranty form provided in the dehumidfier box.
Be sure to note your dehumidifier serial number as you will need it for registration.
The Sentinel Series Dehumidifier must always be connected using a grounded electrical
connection (as required for all electrical appliances). If non-grounded wiring is used, all
liability reverts to owner and the warranty is voided.
Sentinel Dehumidifiers should only be maintained and repaired by a qualified
technician.
Sentinel Dehumidifiers are only intended for operation when oriented with the unit stting
on its feet and level. Operating the unit in any other orientation could allow water to
flood electrical components.
If there is a chance that water flooded the dehumidifier, it should be opened and allowed
to dry thoroughly before reconnecting to electrical power and restarting.
To ensure proper operation, neither the inlet nor discharge should be positioned against
a wall. The inlet requires a minimum of 12”clearance and the discharge requires a
minimum of 36" clearance.
The best option for proper diffusion of air throughout the room is to have the discharge
blowing away from a wall and the inlet pulling air in parallel to a wall.
Always unplug the dehumidifier before moving.
Do not insert your fingers or any object into the inlet or discharge.
AlI work on the dehumidifier should be done with the unit “off” and unplugged.
Do not use water to clean the exterior of the machine. To clean unit, unplug from power,
then use a damp cloth to wipe exterior.
Do not stand on the machine or use it as a device to hang clothes.
PureAiro
DSC 90S
PureAiro DSC 90S
115 V, 60 Hz AC, Single Phase
3-Prong,GFI
15 Amp
02
03
INSTALLATION
The area to be controlled should be sealed with a vapor barrier. If unit is installed in a
crawlspace,all vents should be sealed.
Do not install your dehumidifier in a corrosive environment. Some liquid vapor
barriers dry via“solvent evaporation". Always make sure that barrier is
completely dry and area is throughly ventilated before installing dehumidifier.
WARNING
STEP #1: PLACE DEHUMIDIFIER ON A LEVEL SURFACE.
NOTE: Do not place directly on vapor barrier. Elevation is required to allow the condensate
water to drain via gravity.
If the unit is handled in such a manner that the compressor did not remain in the upright
position,you will need to place it on a level surface, then wait a minimum of 2 hours before
turning“on”.