INDICATOR LIGHTS

ARROW BUTTONS

Use the up and down arrow button to set the desired humidity setpoint on the display screen.

      The setpoint can be any number between 36-90%. Creating a setpoint means that when 
the indoor humidity is lower than the set point, the machine will stop automatically. 
Conversely, when the indoor humidity is higher than the set level, the unit will operate. 

NOTE: The humidty levels

 

displayed are approximate only (+/- 5%)

CONTINUOUS MODE

To switch into continuous mode, set the humidity below 36%. At this point the Cont.light 
should iluminate green on the display board to indicate you have succesfully switched to 
continuous mode. The display screen will show“CO".

When set to continuous, the dehumidifier will run constantly, regardless of the humidity 
level.To stop the dehumidifier from running, turn the unit off or switch back to normal 
humidistat operation. To swtich back to normal humidistat operation, simply move the 
setpoint above 36%.

CENTRAL CONTROL

This mode is not applicable on the PureAiro DSC 90S.

AUXILLARY TERMINALS A5/A6

The A5/A6 on the terminal strip can be used as a safety switch for external condensate 
pumps.It should be set to N/O (normally open) at the dehumidifier. If an E4 error codes, 
switch the wiring to N/C (normally closed).

HUMIDITY DISPLAY SCREEN

The display screen has two functions:

POWER INDICATOR LIGHT

CONTINUOUS MODE/AUTODEFROST LIGHT

This light indicates that the unit is properly powered on and ready to operate. Always make 
sure the unit is "off" prior to performing any service.

When this light iluminates green, it indicates that the dehumidifer is set to continuous 
operation mode.

1. When the unit is powered on, it shows the humidity of the space.
2. While setting the desired humidity level, the screen wil show the set humidity. After a brief 
    delay,the display will revert to current humidity level.

When the light glows red, it means the unit is in auto defrost mode and clearing the 
evaporator coil of any ice buildup.

STEP #2: SET UP DRAIN LINE

The drain line should be routed to a suitable drain on the outside. It must flow down to the
drain without any loops, dips, or valleys.

STEP #3: PLUG UNIT INTO 15 AMP GROUNDED CIRCUIT.

Use this button to turn the dehumidifier on and off. Press once to turn machine on. You will 
hear 2 beeps and the 

  

light will illuminate green. Press the power button a second time and 

you will hear one beep as the machine shuts down. Note that there is a one minute fan delay 
on shutdown.

POWER KEY

Key Functions

88

Power

Cont.

Defrost

Comp

Drain

Central control

1

2

3

4

5

1

2

3

04

05

When the compressor light glows red, it indicates the compressor has been initiated but is 
currenty warming up.
Once the compressor light switches to green, it indicates the compressor is in working 
status.

COMPRESSOR LIGHT

4

RECOMMENDED DRAIN OPTION-TRANSITION TO PVC PIPE

Drain Tube- 12 inches Long.12 mm OD.

Cut a piece of 3/4" OD PVC that is approx. 6”long.

Insert the open end of the tubing into the 3/4" pipe so that it does not extend into the elbow
fitting. For proper flow, a minimum downward slope of 1”per 10' run is required. 
(Note: If a proper downward angle is not possible, then it is recommended to use a 
PureAiro DSC 90S which includes an integrated pump. Alternatively you can use an 
external condensate pump).

Support the PVC tubing so that it maintains a 
smooth downward flow to drain.

Always test the drain before leaving the 
installation area.

1

2

3

4

Insert PVC into a 3/4”elbow, then attach to a 3/4" OD length of PVC to drain. 
(Note: Keep the length of PVC drain pipe to a minimum)

5

When the compressor light glows red, it indicates the compressor has been initiated but is 
currenty warming up.
Once the compressor light switches to green, it indicates the compressor is in working 
status.

COMPRESSOR LIGHT

4

PureAiro 

DSC 90S

Содержание DSC 90S

Страница 1: ...Defrosting System Compatible with Remote Control Notice sold separately Ducting options for divided spaces Small compact and portable Quick access to the main board Quiet operation Engineered for low...

Страница 2: ...eate the perfect environment for allergens like mold and mildew to grow Most homeowners tend to ignore the humidity levels in the crawlspace or basements however research from the American Lung Associ...

Страница 3: ...ers should only be maintained and repaired by a quali ed technician Sentinel Dehumidi ers are only intended for operation when oriented with the unit stting on its feet and level Operating the unit in...

Страница 4: ...f delay the display will revert to current humidity level When the light glows red it means the unit is in auto defrost mode and clearing the evaporator coil of any ice buildup STEP 2 SET UP DRAIN LIN...

Страница 5: ...the dehumidi er in one room with the conditioned air ducted into a second room that contains the remote For example the dehumidi er could be installed in a laundry room and ducted into a living room T...

Страница 6: ...dry space DUCTEDAPPLICATIONS Ducting the dehumidi er allows the unit to be in one room while conditioning an adjacent room The inlet return collar optional accessory PN W 103 is designed for 12 ex duc...

Страница 7: ...power to the outlet and that the plug is properly installed in outlet Power Supply Machine Won t Run Clean the lter mesh according to instructions listed in manual Air Filter is Clogged Low Air Flow C...

Страница 8: ...erti ed repair center all costs associated with freight shipment are borne by the customer In addition all duties related to freight shipments including but not limited to palletizing wrapping labelin...

Отзывы: