TROUBLESHOOTING

SYMPTOM

CAUSE

SOLUTION

Verify that both ends of the
power cord are plugged in

Poor Connection

Display is 
Blank

Clean the filter

Clear the blockage

Filter is Dirty

No Airflow

Error Code: E1

Increase the room temperature
so it is within operating range

(above 3

). If error still

displays, check sensor.

Error Code: E4

Decrease the room temperature
so it is within operating range

(below 40

). If error still

displays, check the sensor

Contact Your Installer for
Assistance

Error Code: LO

Power Outage

Reset power

Air Inlet or Outlet 
is Blocked

Check to ensure that the sensor
wire is connected at both ends.
if no issues a re visible, the
sensor may be faulty.

Verify that the pump is properly
installed and functioning. If so,
unplug the unit for two minutes,
then restart.

Error Code: HI

E5 Error Code

Humidity Sensor or 
Communication Error

Problem with Pump

Room Temperature is 

below 3

Room Temperature is 

above 40

Refrigerant Leak

5

6

7

8

9

Mix a 454g solution of bleach (30 ml 443.6 ml water) OR vinegar (118.3 ml white
v 354.9 ml water).
Pour the cleaning solution into the drain tray at the base of the coils.
If any cleaning solution gets on the coils, flush with water.
Allow solution to soak for 15 minutes.
Reconnect the dehumidifier to power.
Fill the reservoir with water (473.2-946.4 ml) and flush/cycle the pump at least 2x.

DEHUMIDIFIER STORAGE

If the unit will be stored for an extended period of time, complete the 
following steps:

1. Turn off the unit and allow it to dry.
2. Complete steps 1-3 in Advanced Pump Cleaning to clean out the pump reservoir.
3. Wrap and secure the power cord.
4. Cover the filter mesh.
5. Store in a clean, dry space.

DUCTED APPLICATIONS

Ducting the dehumidifier allows the unit to be in one room while conditioning an adjacent 
room. Both the inlet/return grille and the supply grille are designed for 254mm flex ducting.

DUCTING INSTALLATION NOTES

Be sure to secure the ducting with tie wrap.
Maximum total length of duct run = 10’
Inlet and outlet duct adapters are optional accessories

DUCT ADAPTER INSTALLATION

Screw in the 4 screws on each duct adapter.

FLEX DUCT INSTALLATION

Slide ducting over adapter and secure with tie wrap or clamps

Pump Alarm- E4 Error Code

**

UNIT WILL NOT FUNCTION UNTIL ERROR CODE IS CLEARED.

If E4 (pump alarm) is shown on the display, complete the following steps:

1

2

3

4

Reset the unit by unplugging the power cord and then reconnecting it.
Manually check to see if the pump is operational by pressing the drain button. Check if 
the pump energizes and de-energizes properly. Additionally, check to see if any water 
purged from the system.
If you haven’t cleaned the system recently, check the discharge line for an 
obstruction,then clean as described in the Maintenance section.
Replace the hose and/or pump, if maintenance alone isn’t sufficient.

Содержание DSC 120ES

Страница 1: ...ues that crawl spaces present Ducting options for divided spaces Remote Control equiped Heavy Duty Condensate Pump Quick connector to Pump the pump can be taken out freely just full out the quick conn...

Страница 2: ...space basement or whole house where most humidity issues are experienced Equipped with a powerful condensate pump and a pipe all the extracted water is pumped out of the house and poured out away the...

Страница 3: ...damp cloth to wipe the exterior Do not stand on dehumidi er or place objects on it Do not use with extension cord or plug adapter Airflow 350 m H Operating Temp Range 3 40 Operating Relative Humidity...

Страница 4: ...STRUCTIONS PureAiro Dehumidi ers can be controlled using an optional remote accessory The remote connects to your dehumidi er via a 25 CAT 5 cable with the integrated sensor giving you multiple option...

Страница 5: ...Down arrow buttons to adjust the humidity level ON OFF POWER BUTTON UP BUTTON DOWN BUTTON Use the Mode button to switch between dehumidi cation and a ducted application MODE The symbol on the display...

Страница 6: ...side panel and set panel aside Remove the screw holding the pump in place Undo the 3 pump electrical quick connects and 1 drain quick connect Insert a at head screwdriver into the notch on the side o...

Страница 7: ...er 473 2 946 4 ml and ush cycle the pump at least 2x DEHUMIDIFIERSTORAGE If the unit will be stored for an extended period of time complete the following steps 1 Turn o the unit and allow it to dry 2...

Страница 8: ...rti ed repair center all costs associated with freight shipment are borne by the customer In addition all duties related to freight shipments including but not limited to palletizing wrapping labeling...

Отзывы: