PureAiro 

DSC 120ES

INSTALLATION

Place dehumidifier on a level surface.

Do not place unit directly on vapor barrier. For example, use blocks or pavers to create a 
level surface.

1

2

Set up the drain line

Plug dehumidifier into grounded 15 amp circuit.

Remove the compression nut and slide it over the end of the hose to be attached to unit.

WARRANTY REGISTRATION

SPECIFICATIONS

Your dehumidifer comes with an extensive warranty.
For future reference, write down the model, serial number, and date of purchase for your 
dehumidifier. This information is necessary for seeking assistance in the future and can be 
found on the data label on the side of the unit.

Fdca adtora qestors cncemin your diridte. cnatyor
local nsaller or call PureAiro at +44(20)81247965

Model Number:

Serial Number:

Date Of Purchase:

IMPORTANT NOTES

PureAiro DSC 120C

3

Do not use the dehumidifier in standing water. If there is a chance that the dehumidifier 
has been flooded, unplug the unit, remove the cover, and allow it to dry completely before 
proceeding.
Do not insert objects or your fingers into the inlet or discharge.

Your dehumidifier should only be repaired by a qualified technician.

Unless otherwise noted, all maintenance should be done with the unit powered off.

Always connect your dehumidifier using a grounded electrical connection(as required for 
all electrical appliances). The use of non-grounded wiring will void the warranty.

Do not use water to clean the exterior of the dehumidifier. To clean unit,unplug from 
power, then use a damp cloth to wipe the exterior.
Do not stand on dehumidifier or place objects on it.
Do not use with extension cord or plug adapter.

Airflow :

  350 m³/H

Operating Temp. Range: 

 3-40

Operating Relative Humidity Range: 

 36%-90%

COP: 

 3.5 L/kWh

Refrigerant:

  R410A

Amperage Usage: 

 6 Amps

Power Supply:

  230V / 50Hz / Single Phase

Outlet Requirement:

  15 Amp

Sound Level:

  60 dBa

Dimensions L x W x H: 

 600 x 360 x 430mm

If unit has been turned or flipped so that the compressor did not remain upright, place the 
unit on a level surface and wait a minimum of 2 hours before proceeding.

Slide the side of hose with compression nut over the insert on the compression fitting 
completely.
Tighten compression nut.

INSTALLATION REQUIREMENTS

The area where the dehumidifier is located should be sealed with a vapor barrier.
If the unit is installed in a crawl space, all vents should be sealed.
For proper ventilation, neither the inlet or discharge should be positioned against a wall.
The inlet needs a minimum of 12" clearance and the discharge requires a minimum of 
36" clearance.
For the best air diffusion, install the unit so that a side panel faces the wall.
PureAiro dehumidifiers are only intended for operation when the unit is upright and level 
with the feet on the ground.

HOW IT WORKS

PureAiro dehumidifiers use an integrated humidistat to monitor theconditioned space. 
When the relative humidity goes above the selected setpoint, the dehumidifier will energize. 
Air is then drawn across an evaporator coil, which is cooler than the dew point of air. This 
means moisture will condense out of the air. The air is then reheated through the condenser 
coil and distributed back into the room.

Capacity @ 30

/80%RH: 

100 L/Day

Capacity @ 27

/60%RH: 

60 L/Day

Содержание DSC 120ES

Страница 1: ...ues that crawl spaces present Ducting options for divided spaces Remote Control equiped Heavy Duty Condensate Pump Quick connector to Pump the pump can be taken out freely just full out the quick conn...

Страница 2: ...space basement or whole house where most humidity issues are experienced Equipped with a powerful condensate pump and a pipe all the extracted water is pumped out of the house and poured out away the...

Страница 3: ...damp cloth to wipe the exterior Do not stand on dehumidi er or place objects on it Do not use with extension cord or plug adapter Airflow 350 m H Operating Temp Range 3 40 Operating Relative Humidity...

Страница 4: ...STRUCTIONS PureAiro Dehumidi ers can be controlled using an optional remote accessory The remote connects to your dehumidi er via a 25 CAT 5 cable with the integrated sensor giving you multiple option...

Страница 5: ...Down arrow buttons to adjust the humidity level ON OFF POWER BUTTON UP BUTTON DOWN BUTTON Use the Mode button to switch between dehumidi cation and a ducted application MODE The symbol on the display...

Страница 6: ...side panel and set panel aside Remove the screw holding the pump in place Undo the 3 pump electrical quick connects and 1 drain quick connect Insert a at head screwdriver into the notch on the side o...

Страница 7: ...er 473 2 946 4 ml and ush cycle the pump at least 2x DEHUMIDIFIERSTORAGE If the unit will be stored for an extended period of time complete the following steps 1 Turn o the unit and allow it to dry 2...

Страница 8: ...rti ed repair center all costs associated with freight shipment are borne by the customer In addition all duties related to freight shipments including but not limited to palletizing wrapping labeling...

Отзывы: