PURE STERIBASE 300 Скачать руководство пользователя страница 9

Gebrauchsanweisung - 7/24

General information

What to do if one of the fluorescent lamps 
breaks?

– Before cleaning, air the room for around 15 minutes 

and make sure that nobody enters the room during this 
period.

– Protect your hands against shards of glass and mercu-

ry, for example by wearing rubber gloves.

– Do not use a broom, dustpan and brush or vacuum 

cleaner for the initial cleaning process. A vacuum 
cleaner will stir up the mercury, distributing it back into 
the air. 
“Sweep” the shards of glass together using a piece of 
cardboard or similar.

– Gather up smaller shards and powder using a damp 

paper towel or adhesive tape.

– Place all remaining parts of the lamp, shards and pow-

der into an airtight container.

– Only use a vacuum cleaner once this initial cleaning 

process is complete. After vacuuming, clean the vacu-
um cleaner nozzle using a damp paper towel. Dispose 
of the dust bag and dust filter in a dustbin that is not lo-
cated in a sealed room.

– Dispose of any materials that have been heavily soiled. 

Clean any lightly soiled materials, e.g. using adhesive 
tape. Then clean these materials in a washing ma-
chine.

– Wipe down any shoes that have come into direct con-

tact with glass or mercury powder using a damp paper 
towel.

– Any paper towels and adhesive tape used during the 

cleaning process should be placed in the container 
with the broken lamp. Dispose of this waste at a lamp 
waste collection point.

– Dispose of all cleaning materials and the rubber gloves 

in a dustbin that is not located in a sealed room.

– Once the cleaning process is complete, air the room 

again for a short period of time.

– Wash hands thoroughly.

Warning label

The warning label is located on the device near to the On 
/ Off switch.

– The warning label must be replaced immediately if it 

has been damaged or removed or becomes difficult to 
read.

Note:

Fluorescent lamps contain mercury.

Note:

The quantity of mercury released when a fluo-
rescent lamp breaks is too low in general to pose 
a threat to health. 
(Source: Federal Environmental Agency, Ger-
many, 2013)

Note:

Comprehensive information related to broken 
lamps can be found on the German Environmen-
tal Agency's website: 
www.umweltbundesamt.de

The instructions must be read before using 
and opening the device!

The instructions must be read and the mains 
plug removed before opening the device!

Extreme danger! Dangerous voltage!

The device starts up automatically!

Caution, UV-C lamps!

WARNING:

UV rays may cause damage to the eyes and skin.
UV-C components must not be used outside of the 
device.

40332 / 2

Содержание STERIBASE 300

Страница 1: ...Operating instructions EC Declaration of Conformity pure STERIBASE 300...

Страница 2: ......

Страница 3: ...1025009 00 en 07 2020 07 Operating instructions Translation of the original operating instructions pure STERIBASE 300 100003739...

Страница 4: ...22 24 818 205 E mail service jk globalservice de Spare part orders for consumables JK INTERNATIONAL GmbH Division JK Licht K hlershohner Stra e 60 53578 Windhagen GERMANY Tel 49 0 22 24 818 600 Fax 4...

Страница 5: ...Export 10 Environmental protection 10 Warranty 10 Warranty and liability exclusions 11 Description 12 Scope of delivery 12 Description of device 13 Installation and operation 14 Identification on the...

Страница 6: ...nd viruses in the air conducted through it Any other use shall be considered improper The manu facturer cannot be held liable for damage or injuries re sulting from improper use The operator alone bea...

Страница 7: ...ut any maintenance work and before opening the device NeveroperateUV Clampsoutsidethedevice or when it is open DANGER Risk of eye and skin damage due to UV C ra diation Connection to the mains can be...

Страница 8: ...scape Please adhere to the prescribed maintenance inter vals This device may be used by children over the age of 8 persons with reduced physical sensory or mental ca pabilities and persons who have li...

Страница 9: ...con tact with glass or mercury powder using a damp paper towel Any paper towels and adhesive tape used during the cleaning process should be placed in the container with the broken lamp Dispose of th...

Страница 10: ...itube basic IP 100001429 40324 1 40324 2 Stackability on a pallet Keep dry Weight including packaging This way up Permitted temperature during transport and storage Centre of gravity CAUTION Device ma...

Страница 11: ...he inside and outside as well as the protective grille behind the filters for visible soiling on a regular basis Dry cleaning of the filter and protective grille Vacuum cleaner depending on the degree...

Страница 12: ...ice or dealer will be happy to advise you Disposal of Old Devices The device has been manufactured using recyclable ma terials The JK Corporate Group will provide you with in formation on the content...

Страница 13: ...nd protective equipment including warning signs continued operation 10 years after date of manufacture without condition assessment by a certified JK International GmbH service technician not complyin...

Страница 14: ...2020 Description Description Scope of delivery 40326 4 1 11 3 2 4 Scope of delivery 2 100003739 pure STERIBASE 300 1 1024949 Operating instructions 3 1503309 Mains power cable 2 5 m b 1007345 Service...

Страница 15: ...and air outlet 2 Control panel 3 STERITUBE PLUS with 2 UV C lamps 4 Pedestal with fan 5 Air inlet filter three part 6 Mains connection with On Off switch 7 Type plate 8 Warning label 9 Maintenance st...

Страница 16: ...he model type and device no a can be found 1 In Germany VDE regulations DANGER Personal danger due to electric shock or burns Assemblyandelectricalconnectionmustcomply with the national regulations 1...

Страница 17: ...chsanweisung 15 24 Installation and operation Setting up the floor standing device Note Please observe the notes on installation and operation on p 6 40329 1 1 40558 0 2 40559 0 3 ca 45 40563 0 4 4056...

Страница 18: ...00 1025009 00 07 2020 Installation and operation Setting up the floor standing device 230 240 V 40350 1 6 Note If the mains switch is switched on the device starts with the lamps switched off Position...

Страница 19: ...anweisung 17 24 Installation and operation Moving the floor standing device Note Please observe the notes on installation and operation on p 6 230 240 V 40562 0 1 40558 0 2 40559 0 3 ca 45 40563 0 4 4...

Страница 20: ...18 24 pure STERIBASE 300 1025009 00 07 2020 Installation and operation Moving the floor standing device 230 240 V 40350 1 6...

Страница 21: ...1025009 00 07 2020 Installation and operation Switching the device on Switching the device off If the mains switch is switched on the de vice starts with the lamps switched off Po sition 0 230 240 V 4...

Страница 22: ...device off Rectify the fault if possible e g clean the filter clear any covered openings check the mains plug and On Off switch Switch the device on If the red LED continues to light up please call Cu...

Страница 23: ...l as the protective grille behind the filters for visible soiling on a regular basis Dry cleaning of the filter and protective grille Vacuum cleaner depending on the degree of soiling Moist cleaning f...

Страница 24: ...tem connecting cable supplied loose H 1640 mm B 600 mm D 550 mm T1 500 mm H T1 T B 40353 2 Mains connection The scope of delivery includes a power cable with protective earth plug CEE 7 7 The followin...

Страница 25: ...230 m h Level 3 300 m h Sound pressure level measurement LpA Level 1 29 4 dB A Level 2 40 5 dB A Level 3 47 2 dB A Sound power measurement LwA Level 1 39 6 dB A Level 2 51 2 dB A Level 3 58 0 dB A Env...

Страница 26: ...24 24 pure STERIBASE 300 1025009 00 07 2020 EC Declaration of Conformity EC Declaration of Conformity...

Страница 27: ......

Страница 28: ...1025009 JK INTERNATIONAL GMBH K hlershohner Stra e 60 53578 Windhagen Tel 49 0 22 24 818 600 www pure lufthygiene de info pure lufthygiene de pure jk group net...

Отзывы: