Gebrauchsanweisung - 5/24

General information

Safety instructions

1) In Germany: VDE regulations

General safety instructions

– Unauthorized changes to the device are prohibited. 

The manufacturer shall bear no liability for damage or 
injuries resulting from such actions.

– The brackets are sealed to prevent unauthorized open-

ing. Brackets that do not have a seal or brackets with a 
damaged seal may lead to a hazard to the user and to 
the loss of the manufacturer’s guarantee.

– The device is only to be used if it is in perfect working 

order!

– No safety equipment (e.g. stickers, seals, protective 

covers or other components/attached parts) may be 
removed or deactivated if this could impair the safe op-
eration of the device!

– If it is obvious that the device is damaged, it must not 

be put into operation!

– Air intake and air outlet openings should not be cov-

ered!

DANGER!
Personal danger due to electric shock or 
burns!

Assembly and electrical connection must comply 
with the national regulations.

1)

The upgrading, maintenance

 

or repair of the de-

vice may only be carried out by specially trained 
and instructed personnel.
– Disconnect the device from the power supply 

before performing any work.

DANGER!
Risk of eye and skin damage due to UV-C ra-
diation!

Even when radiation periods are short, UV-C ra-
diation can severely damage the skin and, par-
ticularly, the eyes! Direct irradiation of eyes and 
skin must be strictly avoided.
– Disconnect the device from the power supply 

before carrying out any maintenance work 
and before opening the device.

– Never operate UV-C lamps outside the device 

or when it is open!

DANGER!
Risk of eye and skin damage due to UV-C ra-
diation!

Connection to the mains can be made before as 
well as after installation. It is imperative that the 
power supply is switched off during assembly so 
that the device cannot be turned on by mistake 
and UV-C radiation cannot escape.
– Switch off the power supply before assembly 

and back on only after the assembly work has 
been fully completed.

DANGER!
Danger to persons due to maintenance work 
not carried out!

If the maintenance work is not carried out, mate-
rial damage and personal injury may occur!
– Maintenance work may only be carried out by 

persons who have been authorised, trained 
and qualified by JK-International GmbH, JK-
Global Service department!

– The operator is responsible for compliance 

with the maintenance intervals!

CAUTION!

To protect the device from unauthorised opening 
and to secure the guarantee claims, all brackets 
must be sealed! 

CAUTION!

Using unsuitable lamps can eliminate the 
effectiveness of the device and void the 

CE 

conformity

!

– Use genuine UV-C lamps only.

CAUTION!
Risk of damage to the device!

UV-C lamps are sensitive components and may 
be easily damaged.
– Do not touch the lamps with bare hands. 

Wear protective gloves.

– Take care when touching and installing the 

lamps. Do not bend. Do not rest on the pins.

CAUTION!

Only use 

genuine spare parts

 of the same type! 

Using other spare parts can eliminate the 
effectiveness of the device and void the 

CE con-

formity

!

Any liability is excluded in case of damage or 
injury proven to be the result of the use of non-
genuine spare parts.

Содержание STERIBASE 300

Страница 1: ...Operating instructions EC Declaration of Conformity pure STERIBASE 300...

Страница 2: ......

Страница 3: ...1025009 00 en 07 2020 07 Operating instructions Translation of the original operating instructions pure STERIBASE 300 100003739...

Страница 4: ...22 24 818 205 E mail service jk globalservice de Spare part orders for consumables JK INTERNATIONAL GmbH Division JK Licht K hlershohner Stra e 60 53578 Windhagen GERMANY Tel 49 0 22 24 818 600 Fax 4...

Страница 5: ...Export 10 Environmental protection 10 Warranty 10 Warranty and liability exclusions 11 Description 12 Scope of delivery 12 Description of device 13 Installation and operation 14 Identification on the...

Страница 6: ...nd viruses in the air conducted through it Any other use shall be considered improper The manu facturer cannot be held liable for damage or injuries re sulting from improper use The operator alone bea...

Страница 7: ...ut any maintenance work and before opening the device NeveroperateUV Clampsoutsidethedevice or when it is open DANGER Risk of eye and skin damage due to UV C ra diation Connection to the mains can be...

Страница 8: ...scape Please adhere to the prescribed maintenance inter vals This device may be used by children over the age of 8 persons with reduced physical sensory or mental ca pabilities and persons who have li...

Страница 9: ...con tact with glass or mercury powder using a damp paper towel Any paper towels and adhesive tape used during the cleaning process should be placed in the container with the broken lamp Dispose of th...

Страница 10: ...itube basic IP 100001429 40324 1 40324 2 Stackability on a pallet Keep dry Weight including packaging This way up Permitted temperature during transport and storage Centre of gravity CAUTION Device ma...

Страница 11: ...he inside and outside as well as the protective grille behind the filters for visible soiling on a regular basis Dry cleaning of the filter and protective grille Vacuum cleaner depending on the degree...

Страница 12: ...ice or dealer will be happy to advise you Disposal of Old Devices The device has been manufactured using recyclable ma terials The JK Corporate Group will provide you with in formation on the content...

Страница 13: ...nd protective equipment including warning signs continued operation 10 years after date of manufacture without condition assessment by a certified JK International GmbH service technician not complyin...

Страница 14: ...2020 Description Description Scope of delivery 40326 4 1 11 3 2 4 Scope of delivery 2 100003739 pure STERIBASE 300 1 1024949 Operating instructions 3 1503309 Mains power cable 2 5 m b 1007345 Service...

Страница 15: ...and air outlet 2 Control panel 3 STERITUBE PLUS with 2 UV C lamps 4 Pedestal with fan 5 Air inlet filter three part 6 Mains connection with On Off switch 7 Type plate 8 Warning label 9 Maintenance st...

Страница 16: ...he model type and device no a can be found 1 In Germany VDE regulations DANGER Personal danger due to electric shock or burns Assemblyandelectricalconnectionmustcomply with the national regulations 1...

Страница 17: ...chsanweisung 15 24 Installation and operation Setting up the floor standing device Note Please observe the notes on installation and operation on p 6 40329 1 1 40558 0 2 40559 0 3 ca 45 40563 0 4 4056...

Страница 18: ...00 1025009 00 07 2020 Installation and operation Setting up the floor standing device 230 240 V 40350 1 6 Note If the mains switch is switched on the device starts with the lamps switched off Position...

Страница 19: ...anweisung 17 24 Installation and operation Moving the floor standing device Note Please observe the notes on installation and operation on p 6 230 240 V 40562 0 1 40558 0 2 40559 0 3 ca 45 40563 0 4 4...

Страница 20: ...18 24 pure STERIBASE 300 1025009 00 07 2020 Installation and operation Moving the floor standing device 230 240 V 40350 1 6...

Страница 21: ...1025009 00 07 2020 Installation and operation Switching the device on Switching the device off If the mains switch is switched on the de vice starts with the lamps switched off Po sition 0 230 240 V 4...

Страница 22: ...device off Rectify the fault if possible e g clean the filter clear any covered openings check the mains plug and On Off switch Switch the device on If the red LED continues to light up please call Cu...

Страница 23: ...l as the protective grille behind the filters for visible soiling on a regular basis Dry cleaning of the filter and protective grille Vacuum cleaner depending on the degree of soiling Moist cleaning f...

Страница 24: ...tem connecting cable supplied loose H 1640 mm B 600 mm D 550 mm T1 500 mm H T1 T B 40353 2 Mains connection The scope of delivery includes a power cable with protective earth plug CEE 7 7 The followin...

Страница 25: ...230 m h Level 3 300 m h Sound pressure level measurement LpA Level 1 29 4 dB A Level 2 40 5 dB A Level 3 47 2 dB A Sound power measurement LwA Level 1 39 6 dB A Level 2 51 2 dB A Level 3 58 0 dB A Env...

Страница 26: ...24 24 pure STERIBASE 300 1025009 00 07 2020 EC Declaration of Conformity EC Declaration of Conformity...