● Manual override 

● Compatibility with V-Green 270 user interface (sold as separate accessory) 

● High efficiency electromechanical motor and control design 

 
 

 
 
Benefits of adding an optional V-Green 270 user interface  

 

● Ability to conduct field troubleshooting (i.e., view fault codes and real time 

operating parameters) 

● Ability to set the pump’s running schedule based on a real clock setting (i.e., 

must input the actual time which determines when the pump will start and stop) 

● Ability to remotely mount the V-Green 270 user interface (provides easy access 

of user interface depending on your pump’s location) 

● Ability to configure prime speed and prime duration.  

● Ability to configure freeze protection temperature 

● Ability to view actual speed and power of the V-Green 165 in real time 

● Ability to adjust the V-Green 165 motor speed in 25 RPM increments  

● Battery backup to store time setting 

 

 
Startup and Operation  

 

Never operate the pump without water. Water acts as a coolant and lubricant for the 
mechanical shaft seal.  
 
Fill the strainer housing with water to suction pipe level 

 

WARNING-

 

 

Never run the pump dry. Running the pump dry may 

damage seals, causing leakage and flooding. The warranty will not cover any damage 
caused by running the pump dry. Fill strainer housing with water prior to starting motor. 

 

PURELINEPOOL.COM

    TEL: 407-834-2200 

11 

Содержание PL2605

Страница 1: ...Prime 1 65 VS INSTALLATION AND USER GUIDE Model PL2605...

Страница 2: ...est and most reliable motors Failure to read and follow instructions can result in serious injury To prevent potential injury to self or product and to avoid unnecessary service calls please read manu...

Страница 3: ...ted by a ground fault circuit interrupter GFCI Contact a qualified technician if you cannot verify if the circuit is protected by a GFCI Pump must be permanently connected to a GFCI WARNING The pump i...

Страница 4: ...a strong vacuum at the main drain at the bottom of your swimming pool spa This suction is so strong that it can trap adults and children under water if they come in close proximity to the drain The u...

Страница 5: ...tem operates under hazardous pressure Please stand clear of circulation system during pump start up Before servicing your pool equipment make sure all systems and pump controls are in the off position...

Страница 6: ...er Pump Same dimensions as the Hayward Super Pump means no realigning of plumbing significantly reducing the time it takes to swap out your pump Paired with Century s V Green motor the most reliable p...

Страница 7: ...Easy access to all internal parts for servicing Product Dimensions Pump Performance Chart PURELINEPOOL COM TEL 407 834 2200 6...

Страница 8: ...all the pump more than 10 feet above the water level 3 Select a well drained area one that will not flood during the rain 4 Do NOT install pump in a damp or non ventilated location 5 Install the pump...

Страница 9: ...tub structure and to all electrical equipment metal conduit and metal piping within 5 feet 1 5 m of the inside walls of a swimming pool spa or hot tub when the motor is installed within 5 feet of the...

Страница 10: ...sing overload tripping and a reduced component life If the voltage is running at less than 90 or more than 110 of rated voltage when motor is running t full load consult power company Grounding and Bo...

Страница 11: ...maximizes energy consumption Pool size water features and environmental factors will affect optimal programming necessary to maximize energy conservation WARNING The V Green 165 is for use with 208 2...

Страница 12: ...pending on your pump s location Ability to configure prime speed and prime duration Ability to configure freeze protection temperature Ability to view actual speed and power of the V Green 165 in real...

Страница 13: ...ing system If the water source is higher than the pump the pump will prime itself when the suction and outlet valves are open If the water source is lower than the pump unscrew and remove the strainer...

Страница 14: ...otor will automatically start and run the programmed default schedule shown in the chart above This feature ensures that the V Green motor will restart in the event of a power outage V Green 165 Quick...

Страница 15: ...EP 2 STEP 3 or OVERRIDE key Repeat Steps 1 4 to program the corresponding DURATION and SPEED for each button 6 Press START to run the V Green 165 motor based on the programmed 24 hour schedule 7 Press...

Страница 16: ...he event of a breach of warranty within the applicable warranty period Pureline Products shall have the option of 1 repairing 2 supplying an identical or similar replacement or 3 refunding for the pur...

Отзывы: