background image

Novo chrome

Novo passion flower

Novo maple leaf

Novo graphite

©

2012 Pure Glow Limited

2

Содержание NOVO P23G

Страница 1: ...E MODEL P23G All instructions must be handed to user for safekeeping Revision D 12 12 Country s of destination GB IE Pure Glow Limited Stourvale Road Lye Stourbridge West Midlands DY9 8PP Tel 44 1384 893060 Fax 44 1384 897728 e mail info pureglowltd co uk ...

Страница 2: ...Novo chrome Novo passion flower Novo maple leaf Novo graphite 2012 Pure Glow Limited 2 ...

Страница 3: ...should not be used in a room without some form of background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces within the room On first light up of a new appliance burning off of high temperature paint and lubri cants may occur for the first few hours of operation During this period some smoke may be emitted from the outlet...

Страница 4: ...calculate a room size in cubic metres m3 divide the room volume in cubic feet ft3 by 35 3 This appliance may be installed in any room in the home except bathrooms or bedrooms The appliance is designed to be versatile and as such will operate correctly when exposed to normal gentle draughts experienced within the home It is not recommended however that the appliance be installed in areas where it i...

Страница 5: ...ot be positioned vertically within 100 mm 4 of a carpeted floor rugs or fabric materials of any kind This dimension is measured vertically to the bottom of the appliance firebox A minimum of 100 cm 2 purpose provided ventilation MUST be provided for this appliance This may be achieved either with one vent 100 cm 2 at a high or low position in the room or split ventilation i e 50cm 2 be installed a...

Страница 6: ... leaf of a conventional cavity brick wall or a solid wall then the wall plugs and fixing screws provided may be used Depending on the condition of the wall it may be necessary to use additional fixings In this situation any additional fixings and wallplugs should be of the same size and type as the ones provided At the appropriate stage of the installation drill four holes using only a 8mm masonry...

Страница 7: ...ay alight If the pilot is extinguished during use wait three minutes before repeating the ignition procedure To achieve the HIGH setting push the control knob in slightly and continue turning anti clockwise to the high position The main burner should light after a few seconds To decrease the setting to low turn the control knob clockwise to the LOW setting To turn to the PILOT position from the HI...

Страница 8: ...amp cloth and mild detergent on most surfaces Advise that on first light up of a new appliance initial curing of high temperature paint and burning off of lubricants may occur for the first few hours of operation During this period some smoke may be emitted from the outlet grille this should be no cause for concern Accordingly the room should be well ventilated with all windows and doors open duri...

Страница 9: ...eplacements must be original man ufacturers parts Re assembly is the reverse of removal Ensure operating pressures are as stated in Section 2 Appliance Data It is recommended that the catalysts are inspected for signs of damage and dirt during routine servicing procedures The expect ed life of the catalysts is in excess of 11 000 hours 10 years of normal use After this time the catalysts should be...

Страница 10: ...the spark gap see section 7 1 Faulty piezo unit replace Debris shorting out electrode clean Spark shorting to metalwork under tray check routing of HT lead under burner Fire runs for a time Loose or faulty thermocouple rectify and then cuts off Blocked pilot clean out Fire is sited in a draft Door or window has been opened creating a draft Wall on which fire is sited has a hole holes through which...

Страница 11: ...d life of the catalyst is in excess of 11 000 hours 10 years of normal use After this time the catalyst should be replaced Should any home improvements be carried out to the property after the fire is installed such as installation of extractor fans for example the fire should be re checked by a competent person for safe operation U S E R I N S T R U C T I O N S 2 0 CLEARANCES TO COMBUSTIBLES Sect...

Страница 12: ...loth wall coverings or operating the heater where impurities in the air such as tobacco smoke can dle smoke etc exist may cause the walls to become discoloured This appliance is intended as a secondary source of heat only and should not be used in a room without some form of background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on cold...

Страница 13: ... L23 models F730092 Restrictor F730023 Pilot assembly F730086 Gas valve F510075 Burner unit F780079 Catalyst seal kit must also be supplied F940136 Seal kit for Catalyst 7 0 SERVICING 8 0 LIST OF REPLACEMENT PARTS 9 0 INSTALLATION DETAILS Installer GAS SAFE registration No Model Fire serial No Name contact details of installer Supplied by 10 0 SERVICE HISTORY Date of service Serviced by name Conta...

Отзывы: