PUR PUV15H Скачать руководство пользователя страница 6

5

1.

   Determine a suitable location and ensure mounting of the UV system in the 

correct orientation can be completed. In order to install/remove the UV lamp and quartz 
sleeve from the stainless steel chamber, ensure the minimum clearance is double the 
overall length of the unit (Figure 1).

2.

   Attach the mounting clamp to the installation structure using an appropriate screw type 

for both the weight and material of the surface (Figure 2).

3.

    Position the UV reactor chamber into the mounting clamp and secure (Figure 3).

4.

   Install all inlet/outlet plumbing to the system (inclusive of all pre-filtration and valve 

set-ups described above).

5.

   Mount the Electronic Controller in a dry location close to the UV reaction chamber. Install 

power cord and lamp harness using drip loops to prevent moisture from travelling along 
cable and into Controller (Figure 4).

6.

   Ensure the quartz sleeve is intact and that the o-ring, VuCap

®

 retaining ring and retaining 

nut are in position and tightened. Do not overtighten the retaining nuts (Figure 5).

7.

   Connect the four pins of the UV lamp to the UV lamp plug on the Controller (Figure 6).

8.

   Insert the UV lamp into the quartz sleeve and secure the VuCap

®

 protective cover 

(Figure 7 & 8).

9.

   Slowly open the supply valves before and after the UV system and ensure there 

are no water leaks.

10.

  Connect the Electronic Controller to the power outlet, and ensure that both the 

Controller display (indicates lamp life remaining) and the green LED illuminate 
(Figure 9). 
The glow from the UV lamp should also be visible through the VuCap

®

 but note it 

may not be visible in high ambient lighting.

Your UV disinfection system is now ready for use.

NOTE: In order to meet NSF 55 certification the flow restrictor that is included 
with the UV system must be used to control the flow of water through the UV 
chamber. The flow restrictor is designed to thread onto either the inlet or  
outlet ports using Teflon sealing tape for the NPT fittings. In most settings, the 
system should have a manual shut off valve at the input. The water flows in the 
direction of the arrow located on the flow restrictor label.

WARNING: When handling the UV lamps and quartz sleeves, soft 
gloves or a cloth should always be used to prevent oil deposits on 
the surface. Oil deposits from your hands can create hot spots on the 
surface which may lead to premature lamp failure.

Installation Instructions (continued):

System Installation:

Overall Unit Length

Minimum Clearance = x2 Unit Length

Overall Unit Length

Minimum Clearance = x2 Unit Length

Drip 

Loops

2"

3"

If your system is only being used seasonally, it must be stored properly for the winter.  
Disconnect your system from the power source and drain all water from the system. 
Before placing the system back in service, disinfection of the household plumbing system is strongly recommended.

Figure 1

Figure 2

Figure 3

Figure 4

Figure 9

Figure 5

Figure 6

Figure 7

Figure 8

Содержание PUV15H

Страница 1: ...s reserved PUR is a registered trademark used under license from Helen of Troy Limited 210113 Owner s Manual PUV15S PUV25S PUV15H PUV25H Whole Home Ultraviolet Water Disinfection System EPA Establishm...

Страница 2: ...n your UV system unless you have first read and understand all of the warnings and safety instructions that are contained in this manual and on the labels that are affixed to the system Do not attempt...

Страница 3: ...1 E Stainless Steel UV Reaction Chamber 1 Item Description QTY F Owners Manual 1 G Flow Restrictor 1 H Wall Screws 2 I Wall Anchors 2 J VuCap 1 K UV Cylinder Mounting Clamps 2 L Retaining Nut 1 M Quar...

Страница 4: ...te and or local health agency that has jurisdiction If the test results indicate that 1 any of the above contaminant levels are being exceeded or 2 any prevailing drinking water health standards are n...

Страница 5: ...rior to conducting any service on the unit Optional Bypass Line and Drain Valve Water Inlet Water Outlet Water Outlet Water Outlet Water Outlet Optional Bypass Valves Optional Sediment Filter Optional...

Страница 6: ...he power outlet and ensure that both the Controller display indicates lamp life remaining and the green LED illuminate Figure 9 The glow from the UV lamp should also be visible through the VuCap but n...

Страница 7: ...ution lines WARNING Never attempt to service the UV system unless you are an accredited service technician as the performance of the system could be adversely affected In House Water Distribution Syst...

Страница 8: ...aining until lamp replacement is required When countdown timer reaches 0 days an intermittent audible alarm will be activated and the Controller display will indicate alarm A3 In order to allow time t...

Страница 9: ...n must be fully removed from the the quartz sleeve before it is reinstalled in the system Care should be taken to prevent any cleaning fluid from coming into contact with the inside surface of the qua...

Страница 10: ...ace UV lamp System is vibrating Not mounted securely Secure fasteners Water hammer causing vibrations Install a water hammer arrestor in system Excessive heat generated Not being allowed sufficient sp...

Страница 11: ...t where water is microbiologically unsafe or of unknown quality 3 Damage caused by a lack of normal maintenance and cleaning 4 Use of non OEM parts or accessories 5 Damage caused in transit Freight ch...

Страница 12: ...11 Product Notes...

Страница 13: ...st une marque d pos e dont l utilisation est autoris e en vertu d une licence accord e par Helen of Troy Limited Manuel du propri taire PUV15S PUV25S PUV15H PUV25H D sinfection de l eau aux rayons ult...

Страница 14: ...d effectuer un entretien sans avoir lu et bien compris tous les avertissements et les instructions de s curit contenus dans ce manuel et sur les tiquettes appos es sur le syst me N essayez pas de d ma...

Страница 15: ...ion QT F Le manuel du propri taire 1 G Restricteur de d bit 1 H Vis murales 2 I Ancres murales 2 J VuCap 1 K Pinces de montage de cylindre UV 2 L crou de retenue 1 M Joint torique d tanch it de mancho...

Страница 16: ...local en vigueur Si les r sultats des tests indiquent que 1 l un des niveaux de contaminants ci dessus est excessif ou 2 les normes de sant en vigueur en ce qui concerne l eau potable ne sont pas res...

Страница 17: ...ervice sur l appareil Conduite de d rivation et vanne de vidange optionnelles Entr e d eau Sorties d eau Sorties d eau Sorties d eau Sorties d eau Vannes de d rivation optionnelles Filtre s diments op...

Страница 18: ...s que l cran du contr leur indiquant la dur e de vie de la lampe et le voyant DEL vert s allument figure 9 La lumi re de la lampe UV doit galement tre visible travers le VuCap mais elle peut ne pas tr...

Страница 19: ...sants oxyd s n entrent dans les conduites d eau AVERTISSEMENT N essayez jamais d effectuer un entretien sur le syst me UV moins d tre un technicien agr e car vous pourriez endommager le syst me D sinf...

Страница 20: ...cessaire Lorsque le compte rebours affiche 0 jours restants une alarme sonore inter mittente sera activ e et l alarme A3 sera affich e sur l cran Afin de vous laisser le temps de vous procurer une lam...

Страница 21: ...de nettoyage doit tre compl tement enlev e de la gaine de quartz avant que la gaine ne soit r install e dans le syst me Les produits d entretien ne devraient pas entrer en contact avec la surface int...

Страница 22: ...e bien ajust e serr e D faillance de la lampe Remplacez la lampe UV Le syst me vibre Non install de mani re s curitaire V rifiez les fixations et r installez les au besoin Coup de b lier entra nant de...

Страница 23: ...Des dommages caus s par un manque d entretien et de nettoyage normaux 4 L utilisation de pi ces ou d accessoires qui ne proviennent pas du fabricant de l quipement d origine 5 Des dommages caus s par...

Страница 24: ...23 Notes de produit...

Страница 25: ...dos los derechos reservados PUR es una marca registrada utilizada bajo licencia de Helen of Troy Limited Manual del propietario PUV15S PUV25S PUV15H PUV25H Desinfecci n ultravioleta de agua para toda...

Страница 26: ...u sistema UV sin haber le do y entendido todas las advertencias e instrucciones de seguridad que est n contenidas en este manual y en las etiquetas que est n pegadas en el sistema No intente operar el...

Страница 27: ...Limitador de flujo 1 H Tornillos de pared 2 I Anclas de pared 2 J VuCap 1 K Abrazaderas de montaje de cilindro UV 2 L Tuerca de retenci n 1 M Junta t rica de sellado de manga de cuarzo 1 Herramientas...

Страница 28: ...a provincial estatal y o local que tenga jurisdicci n Si los resultados de la prueba indican que 1 se est n superando cualquiera de los niveles de contaminantes anteriores o 2 no se cumplen las normas...

Страница 29: ...io drenar el sistema de agua antes de realizar cualquier servicio a la unidad L nea de desv o y v lvula de drenaje opcionales Entrada de agua Salidas de agua Salidas de agua Salidas de agua Salidas de...

Страница 30: ...de que tanto la pantalla del controlador indica la vida restante de la l mpara como la luz LED verde se iluminan Figura 9 El brillo de la l mpara UV tambi n debe ser vis ible a trav s del VuCap pero t...

Страница 31: ...ENCIA Nunca intente reparar el sistema UV a menos que usted sea un t cnico de servicio acreditado ya que esto podr a da ar el sistema Desinfecci n del sistema de distribuci n de agua dom stico Funcion...

Страница 32: ...requiera reemplazar la l mpara Cuando el temporizador de cuenta regresiva llegue a 0 d as se activar una alarma ac stica intermitente y la pantalla del controlador indicar alarma A3 Con el fin de dar...

Страница 33: ...emoverse completamente de la funda de cuarzo antes de volver a instalarla en el sistema Se debe tener cuidado para evitar que cualquier l quido de limpieza entre en contacto con la superficie interior...

Страница 34: ...star bien ajustada Falla de la l mpara Reemplace la l mpara UV El sistema est vibrando No est montado de forma segura Asegure los tornillos Golpe de ariete causando vibraciones Instale un supresor de...

Страница 35: ...iol gicamente insegura o de calidad desconocida 3 Da os causados por la falta de mantenimiento y limpieza normales 4 Uso de piezas o accesorios que no sean originales del fabricante 5 Da os causados d...

Страница 36: ...35 Notas del producto...

Отзывы: