PumpSpy PS2000UG Скачать руководство пользователя страница 5

Front View:

Switch
UPS Status LED
AC Mode: green lighting

Battery Mode: yellow flashing
Alarm mode: red lighting

3

2

1

NOTE: Rear view receptacle type 
may differ from illustration

Rear View:

LINE INTERACTIVE UPS

PRODUCT OVERVIEW

SPECIFICATIONS

INSTALLATION & INITIAL STARTUP

Model: BU-360
Capacity: 650 VA / 360 W

Inspect this unit before beginning installation. Occasionally, products are damaged during shipment. If any 

components are damaged, contact PumpSpy

 at (833) 786-7779 for assistance.

PLACEMENT & STORAGE CONDITIONS

Install the UPS in a protected area that is free of excessive dust and has adequate air flow. Please place the UPS 

away from other units, at least 20 cm to avoid interference. Do NOT operate the UPS where the temperature 

and humidity is outside the specific limits. (Please check the specs for the  limitations.)

CONNECT TO AC POWER TO BEGIN BATTERY CHARGING

Plug in the AC input cord to the wall outlet. For the best results, charge the battery at least 6 hours before 

initial use. The unit charges its battery while connected to the power.

 

Input

 Voltage

 110V AC / 120 VAC

 Voltage  Range

 81-134 VAC / 89-145 VAC

 

Output

 Voltage  Regulation

 ±10%

 Transfer Time

 Typical 2-6 ms, 10 ms max.

 Waveform

 Simulated Sine Wave

 

Battery

 Type & Number

 12V / 7AH x 1 

  Charging Time

 6 hours recover to 90% capacity

 

PHYSICAL

 Dimension (DxWxH mm)

 297 x 101 x 142

 Net Weight (kgs)

 4.2

 

ENVIRONMENTAL

 Humidity

 0-90 % RH @ 0-40°C (non-condensing)

 Noise Level

 Less than 40 dB

Содержание PS2000UG

Страница 1: ...ury or death INSTALLATION AND OPERATING INSTRUCTIONS System Solid State Pump Controller Power Supply Requirements 120VAC 60 Hz 15 AMP Electrical Ratings 12Amps 120VAC 18 Amps 12VDC Relative Humidity 0 to 80 Storage Temperature 0 to 70 C Operating Temperature 0 to 50 C SPECIFICATIONS PumpSpy PS2000UG The PumpSpy System requires a 12V Deep Cycle Battery not included 40 amp hr minimum 75 amp hr or hi...

Страница 2: ...e connected power cords with wet hands WARNING The PumpSpy System has not been investigated for use in or around swimming pools marine areas recreational water installations decorative fountains or any installation where human contact with the pumped fluid is common WARNING Do not use an extension cord Extension cords could present a safety hazard if not properly sized become damaged or the connec...

Страница 3: ...he WiFi controller 6 Plug the WiFI controller into AC power TEST THE SYSTEM IN THIS ORDER IT S RECOMMENDED TO RUN INITIAL CYCLES WITH WATER AND CHECK ALL PLUMBING FOR LEAKS DURING TESTING Lift the lowest Battery Backup switch and hold Release when the battery backup pump cycles The BACKUP PUMP status LED will remain GREEN The MAIN PUMP status LED will turn RED and the alarm will sound Press ALARM ...

Страница 4: ...ontroller Yellow Blinking Red Red Red Green Alternating MAIN PUMP No Cycle Recorded Main Pump Fail Backup Pump Activated High Amp Draw Jammed Pump Excessive Run Time BACKUP PUMP No Cycle Recorded Backup Pump Fail High Amp Draw Jammed Pump Excessive Run Time WATER LEVEL High Water Alert POWER AC Outage No Battery Reverse Polarity BATTERY Low Battery 25 Charge Critical Battery 10 Charge No Battery R...

Страница 5: ...lace the UPS away from other units at least 20 cm to avoid interference Do NOT operate the UPS where the temperature and humidity is outside the specific limits Please check the specs for the limitations CONNECTTO AC POWERTO BEGIN BATTERY CHARGING Plug in the AC input cord to the wall outlet For the best results charge the battery at least 6 hours before initial use The unit charges its battery wh...

Страница 6: ...ent life support equipment microwave ovens irons or vacuum cleaners to UPS CAUTION Do not plug the UPS input into its own output CAUTION Do not allow liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit CAUTION In the event of an emergency press the OFF button and disconnect the power cord from the AC power supply to prope...

Страница 7: ... is short The UPS is overloaded Remove some devices BatteryVoltage is too low Charge the UPS at least 6 hours Battery Defect It might be due to high temperature operation environment or improper operation to battery Replace the battery with the same type of battery LED is flashing but no apparent issue Reconnect the power cord properly Reconnect the power cord properly TROUBLESHOOTING WARNING Alwa...

Страница 8: ...ransportation or house calls However if you mail your product to PumpSpy for warranty service cost of shipping will be paid one way This warranty does not cover products purchased from a party that is not an authorized retailer dealer or distributor of PumpSpy products OTHER IMPORTANT TERMS This warranty is not transferable and may not be assigned This warranty shall be governed and construed unde...

Отзывы: