SAFETY FIRST!

WARNING

WARNING INDICATES A POTENTIALLY 

HAZARDOUS SITUATION WHICH, IF NOT 

AVOIDED, COULD RESULT IN DEATH, SERIOUS 

INJURY OR MAJOR PROPERTY DAMAGE.

This instruction manual contains very important information for you to know and understand. This 

information is provided for your safety and to help prevent equipment problems from occurring. Please 

observe all safety information labeled danger, warning and caution.

RISK OF ELECTRIC SHOCK. TO REDUCE THIS RISK, OBSERVE THE 

FOLLOWING WARNINGS:

WARNING!   To reduce the risk of electrical shock, this system must be properly grounded in accordance with the 

National Electric Code (NEC) and all applicable state and local codes and ordinances. The receptacle 
should be protected with a Ground Fault Circuit Interrupter (GFCI).

WARNING!   To reduce the risk of electrical shock, always disconnect the pump / system from the power source 

and battery BEFORE handling or servicing.

WARNING!  Never remove the ground prong from the plug, or use an adapter that eliminates the ground prong.

WARNING!  Never plug this system into an electric outlet while standing on a wet surface.

WARNING!   Cables should be protected at all times to avoid punctures, cuts and abrasions that may result in 

exposed wiring. Never handle connected power cords with wet hands.

WARNING!   The PumpSpy

 System has not been investigated for use in or around swimming pools, marine areas, 

recreational water installations, decorative fountains or any installation where human contact with the 
pumped fluid is common. 

WARNING!   Do not use an extension cord. Extension cords could present a safety hazard if not properly sized, 

become damaged or the connection falls into the sump pit. Do not attempt to disassemble the 
PumpSpy controller. There are no field serviceable parts or repair options! 

RISK OF EXPLOSION. TO REDUCE THIS RISK, OBSERVE THE FOLLOWING 

WARNINGS:

WARNING!  Do not use to pump flammable or explosive liquids such as gasoline, fuel oil, kerosene, etc. 

WARNING!  Do not use in a flammable or explosive atmosphere. 

NOT SUITED FOR POTABLE WATER APPLICATIONS. 

WARNING!   Do not use sump pumps to transfer water that will be used for potable 

(drinking) water.

CAUTION INDICATES A POTENTIALLY HAZARDOUS 

SITUATION WHICH, IF NOT AVOIDED, MAY RESULT 

IN MINOR INJURY OR PROPERTY DAMAGE.

CAUTION

TO REDUCE THE RISK OF HAZARDS THAT CAN CAUSE INJURY 

OR PROPERTY DAMAGE, OBSERVE THE FOLLOWING WARNINGS:

CAUTION!   Do not use discharge hose. Discharge hose may whip under pressure. Use rigid piping 

and fittings to secure a pump in the sump basin to reduce movement.

CAUTION! Do not connect any pump if it has been damaged in any way. 
CAUTION! Do not carry or lift a pump by the power cord. Use the pump’s lifting handle.

Содержание PS2000UG

Страница 1: ...ury or death INSTALLATION AND OPERATING INSTRUCTIONS System Solid State Pump Controller Power Supply Requirements 120VAC 60 Hz 15 AMP Electrical Ratings 12Amps 120VAC 18 Amps 12VDC Relative Humidity 0 to 80 Storage Temperature 0 to 70 C Operating Temperature 0 to 50 C SPECIFICATIONS PumpSpy PS2000UG The PumpSpy System requires a 12V Deep Cycle Battery not included 40 amp hr minimum 75 amp hr or hi...

Страница 2: ...e connected power cords with wet hands WARNING The PumpSpy System has not been investigated for use in or around swimming pools marine areas recreational water installations decorative fountains or any installation where human contact with the pumped fluid is common WARNING Do not use an extension cord Extension cords could present a safety hazard if not properly sized become damaged or the connec...

Страница 3: ...he WiFi controller 6 Plug the WiFI controller into AC power TEST THE SYSTEM IN THIS ORDER IT S RECOMMENDED TO RUN INITIAL CYCLES WITH WATER AND CHECK ALL PLUMBING FOR LEAKS DURING TESTING Lift the lowest Battery Backup switch and hold Release when the battery backup pump cycles The BACKUP PUMP status LED will remain GREEN The MAIN PUMP status LED will turn RED and the alarm will sound Press ALARM ...

Страница 4: ...ontroller Yellow Blinking Red Red Red Green Alternating MAIN PUMP No Cycle Recorded Main Pump Fail Backup Pump Activated High Amp Draw Jammed Pump Excessive Run Time BACKUP PUMP No Cycle Recorded Backup Pump Fail High Amp Draw Jammed Pump Excessive Run Time WATER LEVEL High Water Alert POWER AC Outage No Battery Reverse Polarity BATTERY Low Battery 25 Charge Critical Battery 10 Charge No Battery R...

Страница 5: ...lace the UPS away from other units at least 20 cm to avoid interference Do NOT operate the UPS where the temperature and humidity is outside the specific limits Please check the specs for the limitations CONNECTTO AC POWERTO BEGIN BATTERY CHARGING Plug in the AC input cord to the wall outlet For the best results charge the battery at least 6 hours before initial use The unit charges its battery wh...

Страница 6: ...ent life support equipment microwave ovens irons or vacuum cleaners to UPS CAUTION Do not plug the UPS input into its own output CAUTION Do not allow liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit CAUTION In the event of an emergency press the OFF button and disconnect the power cord from the AC power supply to prope...

Страница 7: ... is short The UPS is overloaded Remove some devices BatteryVoltage is too low Charge the UPS at least 6 hours Battery Defect It might be due to high temperature operation environment or improper operation to battery Replace the battery with the same type of battery LED is flashing but no apparent issue Reconnect the power cord properly Reconnect the power cord properly TROUBLESHOOTING WARNING Alwa...

Страница 8: ...ransportation or house calls However if you mail your product to PumpSpy for warranty service cost of shipping will be paid one way This warranty does not cover products purchased from a party that is not an authorized retailer dealer or distributor of PumpSpy products OTHER IMPORTANT TERMS This warranty is not transferable and may not be assigned This warranty shall be governed and construed unde...