PumpSpy PS2000UG Скачать руководство пользователя страница 3

WARNING!  

Electric shock hazard. DISCONNECT power before servicing.  

UNPACKING

Inspect this unit before beginning installation. Occasionally, products are damaged during shipment. If any 

components are damaged, contact PumpSpy

 at (833) 786-7779 for assistance.

1.  Unplug the cellular controller from AC power. 

2.  Disconnect all connections from the back of the cellular controller. 

3.  Open the battery case and disconnect the battery leads from the battery. Dispose of the cellular control box and the 

affixed battery case lid. 

4.  Connect the battery leads from the WiFi controller to the battery. Secure the battery case lid to the existing battery case 

bottom. 

5.  Connect the included adapter to the end of your backup pump’s power cable. Then, reconnect all connections to the WiFi 

controller. 

6.  Plug the WiFI controller into AC power.

TEST THE SYSTEM IN THIS ORDER! IT’S RECOMMENDED TO RUN INITIAL CYCLES WITH WATER AND CHECK ALL 

PLUMBING FOR LEAKS DURING TESTING.

Lift the lowest Battery Backup switch and hold. Release when the battery backup pump cycles. The BACKUP PUMP 

status LED will remain GREEN. The MAIN PUMP status LED will turn RED and the alarm will sound. Press ALARM MUTE 

to silence, if desired.

REFILL BASIN WITH WATER.

Cycle the Primary Sump Pump. The alarm will stop and the MAIN PUMP status LED will turn GREEN.

CONNECT TO A WIFI NETWORK. 

Download the PumpSpy app from the App Store or Google Play. Follow the on-screen 

instructions to connect to a WiFi network. 

The WiFi status LED will turn GREEN after completing the WiFi setup with the 

PumpSpy app.

INSTALLATION

The PumpSpy System requires a 12V Deep Cycle Battery with a minimum 40 AMP/HR 

rating, 75 AMP/HR rating (or higher) recommended. AGM Battery is strongly recommended.

Содержание PS2000UG

Страница 1: ...ury or death INSTALLATION AND OPERATING INSTRUCTIONS System Solid State Pump Controller Power Supply Requirements 120VAC 60 Hz 15 AMP Electrical Ratings 12Amps 120VAC 18 Amps 12VDC Relative Humidity 0 to 80 Storage Temperature 0 to 70 C Operating Temperature 0 to 50 C SPECIFICATIONS PumpSpy PS2000UG The PumpSpy System requires a 12V Deep Cycle Battery not included 40 amp hr minimum 75 amp hr or hi...

Страница 2: ...e connected power cords with wet hands WARNING The PumpSpy System has not been investigated for use in or around swimming pools marine areas recreational water installations decorative fountains or any installation where human contact with the pumped fluid is common WARNING Do not use an extension cord Extension cords could present a safety hazard if not properly sized become damaged or the connec...

Страница 3: ...he WiFi controller 6 Plug the WiFI controller into AC power TEST THE SYSTEM IN THIS ORDER IT S RECOMMENDED TO RUN INITIAL CYCLES WITH WATER AND CHECK ALL PLUMBING FOR LEAKS DURING TESTING Lift the lowest Battery Backup switch and hold Release when the battery backup pump cycles The BACKUP PUMP status LED will remain GREEN The MAIN PUMP status LED will turn RED and the alarm will sound Press ALARM ...

Страница 4: ...ontroller Yellow Blinking Red Red Red Green Alternating MAIN PUMP No Cycle Recorded Main Pump Fail Backup Pump Activated High Amp Draw Jammed Pump Excessive Run Time BACKUP PUMP No Cycle Recorded Backup Pump Fail High Amp Draw Jammed Pump Excessive Run Time WATER LEVEL High Water Alert POWER AC Outage No Battery Reverse Polarity BATTERY Low Battery 25 Charge Critical Battery 10 Charge No Battery R...

Страница 5: ...lace the UPS away from other units at least 20 cm to avoid interference Do NOT operate the UPS where the temperature and humidity is outside the specific limits Please check the specs for the limitations CONNECTTO AC POWERTO BEGIN BATTERY CHARGING Plug in the AC input cord to the wall outlet For the best results charge the battery at least 6 hours before initial use The unit charges its battery wh...

Страница 6: ...ent life support equipment microwave ovens irons or vacuum cleaners to UPS CAUTION Do not plug the UPS input into its own output CAUTION Do not allow liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit CAUTION In the event of an emergency press the OFF button and disconnect the power cord from the AC power supply to prope...

Страница 7: ... is short The UPS is overloaded Remove some devices BatteryVoltage is too low Charge the UPS at least 6 hours Battery Defect It might be due to high temperature operation environment or improper operation to battery Replace the battery with the same type of battery LED is flashing but no apparent issue Reconnect the power cord properly Reconnect the power cord properly TROUBLESHOOTING WARNING Alwa...

Страница 8: ...ransportation or house calls However if you mail your product to PumpSpy for warranty service cost of shipping will be paid one way This warranty does not cover products purchased from a party that is not an authorized retailer dealer or distributor of PumpSpy products OTHER IMPORTANT TERMS This warranty is not transferable and may not be assigned This warranty shall be governed and construed unde...