In order to get the most from your PumpSpy system, activate the PumpSpy Remote 
Monitoring Service. The PumpSpy Remote Monitoring Service computers connect 
to your PumpSpy System and watch over your system automatically, 24 hours a day. 
PumpSpy collects operating data on your sump pumps and battery and then analyzes 
this information to make sure your pumps are always in top working condition. The 
PumpSpy Remote Monitoring Service activates and tests your pumps at least three 
times per week. 

IF A PROBLEM IS DETECTED AT ANY TIME, THE PUMPSPY SYSTEM 

WILL SEND AN ALERT TO YOUR EMAIL AND MOBILE PHONE. 

You can have alerts sent to as many people as you like at no extra charge.  

           YOU MUST COMPLETE ALL PLUMBING AND THE INSTALLATION PROCESS BEFORE 

          REGISTERING  YOUR SYSTEM! THE PUMPSPY MONITORING SERVICE WILL ACTIVATE  

          AND TEST YOUR PUMPS DURING THE REGISTRATION PROCESS!

1.  

LOCATE YOUR PUMPSPY SERIAL NUMBER

     With your documentation, there is a registration card with your system’s serial number. If you are unable to locate 
    this document, the serial number is also printed on the side of the PumpSpy System Controller.

2. 

VISIT WWW.PUMPSPY.COM 

 

   Once you are on the website, click the “Login/Activate” button. The website will walk you through the registration  
   process, step by step.

A valid credit card is required to activate the PumpSpy Remote Monitoring Service. Your card will not be charged until 
the 30 day trial period expires. There is no long term commitment and you can cancel the service at any time. For 
terms and conditions, visit www.pumpspy.com

ACTIVATE THE PUMPSPY REMOTE  

MONITORING SERVICE

TROUBLESHOOTING  

For additional help, visit the FAQ at pumpspy.com or call 

515.999.6935

PROBLEM

POTENTIAL CAUSE

POSSIBLE SOLUTION

   WARNING!

  Always disconnect the pump from the electrical power source BEFORE handling  

                     or servicing.

Backup Pump will not run

 

Data light blinks red

No Primary Pump Cycles 

recorded

Loose connections 
Low or defective Battery
Float Switch is restricted
Unit is not registered
Poor cell signal

Subscription Suspended

Primary Pump not connected

Make sure all connections to Controller are secure
Check battery and replace if necessary

Make sure the float switch is not obstructed by wires or debris

Register unit online at pumpspy.com to start data sync

Move antenna to better location. Press ALARM MUTE to see 

signal strength. 

Logon to pumpspy.com and update payment method

Plug Primary Sump Pump into AC outlet on PumpSpy™  

Controller

© PumpSpy Technology, LLC   Questions? 

Call Tech Support: 515.999.6935

Содержание PS1000

Страница 1: ... MAX Flow 12VDC Brushless DC 18 Amps 40 F to 120 F 1 1 2 NPT 3000 GPH System Solid State Pump Controller Power Supply Requirements Electrical Ratings Relative Humidity Storage Temperature Operating Temperature 120VAC 60 Hz 15 AMP 12Amps 120VAC 18 Amps 12VDC 0 to 80 0 to 70 C 0 to 50 C SPECIFICATIONS PumpSpy PS1000 PumpSpy Tech Support 515 999 6935 support PumpSpy com 34000 LEAR INDUSTRIAL PARKWAY ...

Страница 2: ...ot been investigated for use in or around swimming pools marine areas recreational water installations decorative fountains or any installation where human contact with the pumped fluid is common WARNING Do not use an extension cord Extension cords could present a safety hazard if not properly sized become damaged or the connection falls into the sump pit Do not attempt to disassemble the PumpSpy ...

Страница 3: ...harge 2 Cut a 3 ft section of 1 1 2 in rigid PVC pipe Glue 1 1 2 in pipe to a threaded fitting 3 Screw pipe from step 2 into pump discharge 4 Place the pump with the 3 ft section of PVC pipe on a solid level surface in the sump pit Do NOT place the pump on a loose or sandy surface Small stones or sand may damage the pump resulting in pump failure 5 Attach a check valve sold separately to the top o...

Страница 4: ...od 2 8 Glue a short piece of PVC pipe between the 45º elbow and the Y THE CHECKVALVES FOR BOTH PUMPS MUST BE INSTALLED BELOWTHE Y FITTING The remainder of the discharge pipe installation will vary depending on individual circumstances Using sound plumbing practices route the discharge pipe to an exterior wall by the shortest distance AFTER PLUMBING IS COMPLETED FOR BOTH METHODS 1 AND 2 Install flo...

Страница 5: ...battery case and place 12Volt battery inside 8 Connect the PumpSpy controller to the battery Red to Black to Replace and lock lid on case 9 Plug the PumpSpy controller into an AC outlet Consult your local codes for GFCI requirements 10 The PumpSpy system will initialize and boot up After booting the POWER and SYSTEM lights should be GREEN The DATA light should be BLINKING RED TESTTHE SYSTEM INTHIS...

Страница 6: ...ite click the Login Activate button The website will walk you through the registration process step by step A valid credit card is required to activate the PumpSpy Remote Monitoring Service Your card will not be charged until the 30 day trial period expires There is no long term commitment and you can cancel the service at any time For terms and conditions visit www pumpspy com ACTIVATE THE PUMPSP...

Страница 7: ...ds normal value Voltage Low Displayed when battery voltage drops below 11 4 volts 50 discharged Voltage Critical Displayed when battery voltage drops below 10 4 volts 90 discharged Primary Hi Amps Displayed when primary pump current exceeds baseline amp reading by 50 System Error Displayed when alarm for an alert is muted Sig Strgth xx Display of signal strength as read from cellular module press ...

Страница 8: ...service cost of shipping will be paid one way This warranty does not cover products purchased from a party that is not an authorized retailer dealer or distributor of PumpSpy products OTHER IMPORTANT TERMS This warranty is not transferable and may not be assigned This warranty shall be governed and construed under the laws of the state of Ohio The warranty period will not be extended by any replac...

Отзывы: