PumpSpy PS1000 Скачать руководство пользователя страница 3

WARNING! 

 

Turn power to main pump off! 

WARNING! 

 

Electric shock hazard. DISCONNECT power before servicing. 

  

• 

Backup Pump must be installed using 1-1/2 in. rigid PVC pipe!

• 

DO NOT over tighten or cross-thread plastic fittings or check valves.

• 

Check valves MUST be installed in the discharge line of both the main AC pump and the  

   back-up DC pump.

• 

Installation of this unit MAY take several hours. Before disabling your main pump, have a standby  

   pump ready or an appropriate means of evacuating the sump basin. 

• 

Verify that the existing AC pump is in good working order. If the AC pump is questionable, replace.

• 

Remove any debris from the sump pit and surrounding area.

UNPACKING

Inspect this unit before beginning installation. Occasionally, products are damaged during shipment. If the pump 

or any components are damaged, contact PumpSpy

 at  515.999.6935, or [email protected].

METHOD 1 (Separate discharge line) - See Figure 1  

     1. The backup pump has a 1-1/2 in. NPT discharge.   
     2. Cut a 3 ft. section of 1-1/2 in. rigid PVC pipe.  

        Glue 1-1/2 in. pipe to a threaded fitting. 

 

     3. Screw pipe from step 2 into pump discharge. 
     4. Place the pump with the 3 ft. section of PVC pipe on  
        a solid, level surface in the sump pit. Do NOT place the    
        pump on a loose or sandy surface. Small stones or sand  
        may damage the pump resulting in pump failure.
     5. Attach a check valve (sold separately) to the top  
       of the discharge pipe. A check valve is required for proper  
       operation of system.

The remainder of the discharge pipe installation will vary 

depending on individual circumstances. Using sound plumbing 
practices, route the discharge pipe to an exterior wall by the 
shortest path. Keep turns to a minimum because they reduce 

flow output of the pump. 

The PumpSpy

 Backup Pump can be installed with a separate discharge line (Method 1), or 

connected to an existing discharge line (Method 2).

FIGURE 1- 

Separate discharge line

INSTALLATION

© PumpSpy Technology, LLC   Questions? 

Call Tech Support: 515.999.6935

WARNING

The PumpSpy System requires a 12V Deep Cycle Battery with a minimum  

75AMP/HR rating.  AGM Battery is strongly recommended. 

BEFORE INSTALLING BACKUP PUMP

Содержание PS1000

Страница 1: ... MAX Flow 12VDC Brushless DC 18 Amps 40 F to 120 F 1 1 2 NPT 3000 GPH System Solid State Pump Controller Power Supply Requirements Electrical Ratings Relative Humidity Storage Temperature Operating Temperature 120VAC 60 Hz 15 AMP 12Amps 120VAC 18 Amps 12VDC 0 to 80 0 to 70 C 0 to 50 C SPECIFICATIONS PumpSpy PS1000 PumpSpy Tech Support 515 999 6935 support PumpSpy com 34000 LEAR INDUSTRIAL PARKWAY ...

Страница 2: ...ot been investigated for use in or around swimming pools marine areas recreational water installations decorative fountains or any installation where human contact with the pumped fluid is common WARNING Do not use an extension cord Extension cords could present a safety hazard if not properly sized become damaged or the connection falls into the sump pit Do not attempt to disassemble the PumpSpy ...

Страница 3: ...harge 2 Cut a 3 ft section of 1 1 2 in rigid PVC pipe Glue 1 1 2 in pipe to a threaded fitting 3 Screw pipe from step 2 into pump discharge 4 Place the pump with the 3 ft section of PVC pipe on a solid level surface in the sump pit Do NOT place the pump on a loose or sandy surface Small stones or sand may damage the pump resulting in pump failure 5 Attach a check valve sold separately to the top o...

Страница 4: ...od 2 8 Glue a short piece of PVC pipe between the 45º elbow and the Y THE CHECKVALVES FOR BOTH PUMPS MUST BE INSTALLED BELOWTHE Y FITTING The remainder of the discharge pipe installation will vary depending on individual circumstances Using sound plumbing practices route the discharge pipe to an exterior wall by the shortest distance AFTER PLUMBING IS COMPLETED FOR BOTH METHODS 1 AND 2 Install flo...

Страница 5: ...battery case and place 12Volt battery inside 8 Connect the PumpSpy controller to the battery Red to Black to Replace and lock lid on case 9 Plug the PumpSpy controller into an AC outlet Consult your local codes for GFCI requirements 10 The PumpSpy system will initialize and boot up After booting the POWER and SYSTEM lights should be GREEN The DATA light should be BLINKING RED TESTTHE SYSTEM INTHIS...

Страница 6: ...ite click the Login Activate button The website will walk you through the registration process step by step A valid credit card is required to activate the PumpSpy Remote Monitoring Service Your card will not be charged until the 30 day trial period expires There is no long term commitment and you can cancel the service at any time For terms and conditions visit www pumpspy com ACTIVATE THE PUMPSP...

Страница 7: ...ds normal value Voltage Low Displayed when battery voltage drops below 11 4 volts 50 discharged Voltage Critical Displayed when battery voltage drops below 10 4 volts 90 discharged Primary Hi Amps Displayed when primary pump current exceeds baseline amp reading by 50 System Error Displayed when alarm for an alert is muted Sig Strgth xx Display of signal strength as read from cellular module press ...

Страница 8: ...service cost of shipping will be paid one way This warranty does not cover products purchased from a party that is not an authorized retailer dealer or distributor of PumpSpy products OTHER IMPORTANT TERMS This warranty is not transferable and may not be assigned This warranty shall be governed and construed under the laws of the state of Ohio The warranty period will not be extended by any replac...

Отзывы: