PumpSpy PS1000 Скачать руководство пользователя страница 5

CONNECTING PUMPSPY

™ 

CONTROLLER

1. Install the Primary Sump Pump and Backup Pump using good plumbing 

practices. Both the Primary and Backup pumps should set on the bottom of the 

basin.

2. Install the switches for the primary pump and backup pump. The ON level of 
the lowest backup switch should be approximately 1” higher than the ON level 

of the primary sump pump switch.

3. Connect the Backup Sump Pump to the PumpSpy

 Controller’s white jack.

4. Connect the backup switches to the PumpSpy

 Controller’s color coded 

jacks.

5. 

VERY IMPORTANT! 

Connect the Main Sump Pump to the AC outlet on 

the PumpSpy

 controller.

6. Mount the PumpSpy

™ 

Controller’s antenna as high as possible, preferably 

at

tached to a floor joist or external wall. Remove the backing from the 

antenna’s mounting tape, and fasten the antenna. Press ALARM MUTE to see 

signal strength.  Avoid copper pipes, metal conduits, electrical wiring, or other  

metal surfaces. 

7. Open the battery case and place 12 Volt battery inside.

8. Connect the PumpSpy

 controller to the battery. Red to +, Black to -. 

Replace and lock lid on case.

9.  Plug the PumpSpy

 controller into an AC outlet. Consult your local codes 

for GFCI requirements.

10.  The PumpSpy

 system will initialize and boot up.  After booting, the 

POWER and SYSTEM lights should be GREEN.  The DATA light should be 
BLINKING

 RED.   

 
TEST THE SYSTEM IN THIS ORDER! FILL BASIN WITH WATER, 

BELOW THE PRIMARY SUMP PUMP’S ON LEVEL.  CHECK 

PLUMBING FOR LEAKS DURING TESTING.

Lift the lowest Battery Backup switch and hold. Release when the battery 
backup pump cycles. The PumpSpy

 controller should sound an alarm with the 

message Backup On AC On. The SYSTEM light will turn red. 

REFILL BASIN WITH WATER.

Lift the switch for the Primary Sump Pump. Release when Primary Pump cycles 
for at least 3 seconds. The PumpSpy

 alarm will stop and the SYSTEM light will 

be green.

The PumpSpy

 system will begin data sync and the DATA light will turn 

BLINKING GREEN after the registration process is complete at PumpSpy

.

com

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

© PumpSpy Technology, LLC   Questions? 

Call Tech Support: 515.999.6935

Содержание PS1000

Страница 1: ... MAX Flow 12VDC Brushless DC 18 Amps 40 F to 120 F 1 1 2 NPT 3000 GPH System Solid State Pump Controller Power Supply Requirements Electrical Ratings Relative Humidity Storage Temperature Operating Temperature 120VAC 60 Hz 15 AMP 12Amps 120VAC 18 Amps 12VDC 0 to 80 0 to 70 C 0 to 50 C SPECIFICATIONS PumpSpy PS1000 PumpSpy Tech Support 515 999 6935 support PumpSpy com 34000 LEAR INDUSTRIAL PARKWAY ...

Страница 2: ...ot been investigated for use in or around swimming pools marine areas recreational water installations decorative fountains or any installation where human contact with the pumped fluid is common WARNING Do not use an extension cord Extension cords could present a safety hazard if not properly sized become damaged or the connection falls into the sump pit Do not attempt to disassemble the PumpSpy ...

Страница 3: ...harge 2 Cut a 3 ft section of 1 1 2 in rigid PVC pipe Glue 1 1 2 in pipe to a threaded fitting 3 Screw pipe from step 2 into pump discharge 4 Place the pump with the 3 ft section of PVC pipe on a solid level surface in the sump pit Do NOT place the pump on a loose or sandy surface Small stones or sand may damage the pump resulting in pump failure 5 Attach a check valve sold separately to the top o...

Страница 4: ...od 2 8 Glue a short piece of PVC pipe between the 45º elbow and the Y THE CHECKVALVES FOR BOTH PUMPS MUST BE INSTALLED BELOWTHE Y FITTING The remainder of the discharge pipe installation will vary depending on individual circumstances Using sound plumbing practices route the discharge pipe to an exterior wall by the shortest distance AFTER PLUMBING IS COMPLETED FOR BOTH METHODS 1 AND 2 Install flo...

Страница 5: ...battery case and place 12Volt battery inside 8 Connect the PumpSpy controller to the battery Red to Black to Replace and lock lid on case 9 Plug the PumpSpy controller into an AC outlet Consult your local codes for GFCI requirements 10 The PumpSpy system will initialize and boot up After booting the POWER and SYSTEM lights should be GREEN The DATA light should be BLINKING RED TESTTHE SYSTEM INTHIS...

Страница 6: ...ite click the Login Activate button The website will walk you through the registration process step by step A valid credit card is required to activate the PumpSpy Remote Monitoring Service Your card will not be charged until the 30 day trial period expires There is no long term commitment and you can cancel the service at any time For terms and conditions visit www pumpspy com ACTIVATE THE PUMPSP...

Страница 7: ...ds normal value Voltage Low Displayed when battery voltage drops below 11 4 volts 50 discharged Voltage Critical Displayed when battery voltage drops below 10 4 volts 90 discharged Primary Hi Amps Displayed when primary pump current exceeds baseline amp reading by 50 System Error Displayed when alarm for an alert is muted Sig Strgth xx Display of signal strength as read from cellular module press ...

Страница 8: ...service cost of shipping will be paid one way This warranty does not cover products purchased from a party that is not an authorized retailer dealer or distributor of PumpSpy products OTHER IMPORTANT TERMS This warranty is not transferable and may not be assigned This warranty shall be governed and construed under the laws of the state of Ohio The warranty period will not be extended by any replac...

Отзывы: