ITEM
SELECTION
DESCRIPTION
NiMH
Sensitivity
D.Peak
Default
Default: 4mV/Cell
3-15mV/Cell
This setting is for NiMH/NiCd battery only.
When the charger detects that the delta peak
value you set has been reached, the charger
will say the battery is fully charged.
NiCd
Sensitivity
D.Peak
Default
Key Beep ON
Buzzer ON
OFF/ON
Key Beep sounds every time you press a
button. Buzzer beep or melody sounds at
various instances during operation to alert
certain process events.
DC Input. Low
Cut-Off 11.0V
10.0-11.0V
This setting controls the DC input voltage.
If the voltage drops below the value you set
the charging operation will be terminated to
protect the input channel.
BAL.Connection
ON
OFF/ON
The default setting for charging Lithium
batteries is the use of a balance adaptor to
connect the battery and charger in Charge,
Fast Charge, Balance Charge and Storage
modes. This function could be disabled here.
AC Max Power Set
100W
0-100W
It is to set the max AC power of the present
channel. Once you set it, the other channel
will take the remaining power.
Max Charge Power for CH A/CH B 100W
Max Charge Power for CH C/CH D 50W
Load Factory Set
Enter
Press ENTER to load factory default setting.
Version
HW:1.00 SW: 1.00
It indicates the hardware and firmware
version.
System Setting