background image

 

 
Table 5. Mechanical parameters 

Dimensions 

W=397, H=350, D+D

1

=92+8 [+/- 2mm] 

W

1

=402, H

1

=355 [+/- 2mm] 

The dimensions of the battery 
compartment 

170 x 110 x 65mm (WxHxD) max 

Gross/Net weight 

4,2 / 4,5 kg 

Enclosure 

Steel plate, DC01 1,0mm color white RAL 9003 

Closing 

Cheese head screw x 2 (at the front), (lock assembly possible) 

Connectors 

Power supply of the cameras:  RJ45 socket 
Input 230 V AC: 

Φ 0,63-2,50 (AWG 22-10) 

Battery output BAT: 6,3F-2,5  
TAMPER output: wires  

Notes 

The enclosure does not touch the assembly surface so that cables can be led. 

 
Table 6. Operation safety 

Protection class PN-EN 609501:2007  

I (first) 

Protection grade PN-EN 60529: 2002 (U)  

IP20 

Electrical strength of insulation: 
- between input and output circuits of the PSU  
- between input circuit and protection circuit  
- between output circuit and protection circuit  

 

3000 V AC min. 
1500 V AC min. 
  500 V AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 

100 MΩ, 500V DC 

Declarations 

CE 

 

Table 7. Operating parameters

 

Operating temperature 

-

10ºC...+40ºC 

Storage temperature 

-

20ºC...+60ºC 

Relative humidity 

20%...90%, without condensation 

Vibrations during operation 

unacceptable 

Impulse waves during operation 

unacceptable 

Direct insulation 

unacceptable 

Vibrations and impulse waves during transport 

According to PN-83/T-42106 

 

2.  Installation 

2.1. Installation procedure 

The device should be mounted by a qualified installer, holding relevant permits and licenses (applicable and  required  for  

a  given  country)  for  230 V and  low-voltage  installations. It is required to install an installation switch with a nominal current 
of min. 3 A in the power supply circuits outside the power supply unit. 

The  device  shall  be  mounted  in  confined  spaces,  according  to  the  environment  class  II,  with  normal  air  humidity 

(RH=90% max. without condensation) and the temperature from -

10°C to +40°C.  

The  switch  shall  work  in  a  vertical  position  that  guarantees  sufficient  convectional  air-flow  through  ventilating  holes  of  the 
enclosure.  

 
Before installation, prepare a Switch'a load balance.  

 
The given value of 30 W per port is the maximum value referring to a single output. The total power consumption 

should  not  exceed  48  W

.  The  increased  demand  for  power  is  particularly  evident  in  the  case  of  cameras  with  heaters  or 

infrared illuminators - when launching these features, the power consumption increases rapidly, which may adversely affect the 
operation of the switch. As the device is designed for a continuous operation and is not equipped with a power-switch, therefore 
an appropriate overload protection shall be guaranteed in the power supply circuit. Moreover, the user shall be informed about 
the  method  of  unplugging  (usually  through  assigning  an  appropriate  fuse  in  the  fuse-box).  The  electrical  system  shall  follow 
valid standards and regulations. 
 

2.2.  Installation procedure 

 

 

Before installation, cut off the voltage in the 230 V power-supply circuit. 

To switch power off, use an external switch, in which the distance between the contacts of all 

poles in the disconnection state is not less than 3mm. 

 

 
 
 
1. Mount the PSU in a selected location and connect the wires.  
2. Connect the power cables (230 V) to L-N clips of the PSU.  
 
 
 

Содержание S64-B17

Страница 1: ...ure color white RAL 9003 with battery space for a 17 Ah 12 V battery Supports auto learning and auto aging of MAC addresses 1K size warranty 2 year from the production date Example of use CONTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of components and connectors 1 4 Technical parameters 2 Installation 2 1 Requirements 2 2 Installation procedure 3 Indica...

Страница 2: ...p time assumptions for calculations Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 4 ports of the switch The UP LINK ports is used for connection of another network device e g recorder The LEDs at the front panel indicate the operation status description in the table 8 The switch is housed in a metal enclosure color RAL 9003 which can accommodate a 1x17 Ah 1...

Страница 3: ...ch PoE 2 Switch mode buffer power supply unit 3 DC DC52115 converter 4 Output filter 5 Tamper micro switch terminals of tamper protection NC 6 Battery space for a 17 Ah 12 V battery 7 Power supply connector of the PSU L N Protective connector electric shock 8 BAT BAT battery output BAT red BAT black Fig 3 The view of the switch ...

Страница 4: ...upply Link Act PoE Status The given value of 30 W per port is the maximum value The total power consumption should not exceed 48 W Table 4 Electrical parameters Mains supply 200 240 V 50 Hz Current up to 0 7 A Supply power 55 W Output current at the PoE ports RJ45 4 x 0 6 A ΣI 1 A max Output voltage at the PoE ports RJ45 52 V DC Short circuit protection SCP and overload protection OLP 105 150 PSU ...

Страница 5: ... and low voltage installations It is required to install an installation switch with a nominal current of min 3 A in the power supply circuits outside the power supply unit The device shall be mounted in confined spaces according to the environment class II with normal air humidity RH 90 max without condensation and the temperature from 10 C to 40 C The switch shall work in a vertical position tha...

Страница 6: ...ctor Connect the ground wire to the clip marked by the earth symbol Use a three core cable with a yellow and green protection wire to make the connection Lead the cables to the appropriate clips through the insulating bushing of the connection board 4 Connect the power 230 V 5 Connect the battery mind the colours battery output V BAT cable red battery output 0V BAT cable GND black 6 Connect the ca...

Страница 7: ...PoE PORTS 1 4 GREEN LED LIGHT PoE Indication of the PoE power supply at the RJ45 ports OFF no power supply at the RJ45 port the device is not connected or not compliant with the IEEE802 3af at standard ON supply at the RJ45 port Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10 M s or 100 Mb s and data transmission OFF no connection ON the devi...

Страница 8: ...e PSU from the power supply network The PSU does not require performing any specific maintenance measures however in case of significant dust rate its interior is recommended to be cleaned with compressed air In case of fuse replacement use a replacement of the same parameters WEEE LABEL Waste electrical and electronic equipment must not be disposed of with normal household waste According to the ...

Отзывы: