www.pulsar.pl

    

 

 

 

RSUPS98R 

 

 

 

            

RACK POWER 

 

 

2.2. Installation procedure. 

 

1. Before installation, cut off the voltage in the 230V power-supply circuit. 

2. Mount the power supply in a RACK 19" cabinet as shown below: 

 

- Mount M6 cage nuts 

 

- Secure the enclosure with 4xM6 screws 

 
3. Connect the batteries in series/parallel to the + BAT- terminals: 
             - battery output (V+): terminal BAT+ 

- battery output (V-): terminal BAT- 

4. Connect the ~230V AC power cord with the IEC C13 plug (included) to the 230V AC power supply and turn on 
the power (~230V). 
5. Connect the camera cables to the RJ45 connectors (PoE connectors) and connect the recorder to the network 
(the UPLINK connector). 
6. Connect the power supply of the DVR (by default, the device is equipped with a cable terminated with the DC 2.1 
/ 5.5 plug).  
7. Make the following technical connections when needed: 
ALARM 

– technical output of collective failure indication 

8. Check the optical indication of the switch operation. 

 

3.  Indication of the device operation. 
 

3.1.  LED indication of operating status. 

The PSU has 6 LED lights at the front panel: 
 

 

 
 

 

 
 
 

 

 
 

 

 
 
 

 

 
 
 

 

GREEN LED: 

 

on 

– the PSU is supplied with 230V AC 

 

off 

– no 230V AC supply 

 
GREEN LED: 

 

on 

– DC voltage at the output of the switch mode PSU 

 

off 

– no DC voltage at the output of the switch mode PSU 

 
RED LED: 

 

on 

– failure 

 

off 

– no failure 

 
 
 
RED LED: 

 

ON 

– too high temperature of the switch mode power supply 

(>70°C) 

 

OFF 

– standard temperature of the switch mode power supply 

 
 
RED LED: 

 

on 

– battery voltage <23V 

 

off 

– battery voltage >23V 

 

 
GREEN LED: 

 

ON 

– DC voltage at the NVR output 

 

OFF - no DC voltage at the NVR output 

 

 

Содержание RSUPS98R

Страница 1: ...RSUPS98R v 1 0 9 port switch for 8 IP cameras IP with battery backup for cameras and recorder RACK mounted EN Edition 1 from 28 06 2016 Supercedes the edition ...

Страница 2: ...data transfer and power supply 15 4W for each PoE port supports devices complaint with the IEEE802 3af standard Supports auto learning and auto aging of MAC addresses 1K size wide range of mains supply AC 176 264V AC battery charging and maintenance control excessive discharging UVP protection battery output protection against short circuit and reverse connection battery charge current 1A voltage ...

Страница 3: ...ating status of the device The switch is fitted with the ALARM technical output of collective failure In the case of failure a LED light is activated which is accompanied by switching of relay contacts and acoustic indication The PoE technology ensures a network connection and reduces installation costs by eliminating the need to supply a separate power cable for each device This method allows sup...

Страница 4: ...position indication OFF PoE port 1 4 for cameras IP connection data power supply PoE port 5 8 for cameras IP connection data power supply UPLINK port for recorder data 230V AC INPUT power socket 230V AC power cable 1 5m included FMAINS fuse in the supply circuit 230V AC T 6 3A 250V Fig 2 The front power of the power supply unit Fig 3 The view of the PSU ...

Страница 5: ...e of 15 4W per port is the maximum value The total power consumption should not exceed 96W when all PoE ports are being used Electrical parameters tab 4 Mains supply 176 264V AC Current up to 1 1A 230V AC max Supply power 172W max Output voltage at the PoE ports Output voltage the recorder NVR 48V DC maintained regardless of the state of battery charge 12V DC maintained regardless of the state of ...

Страница 6: ...out condensation Vibrations during operation unacceptable Impulse waves during operation unacceptable Direct insulation unacceptable Vibrations and impulse waves during transport According to PN 83 T 42106 2 Installation 2 1 Requirements The PSU RACK shall be mounted by a qualified installer with appropriate permissions and qualifications for 230V AC installations and low voltage installations req...

Страница 7: ...f the DVR by default the device is equipped with a cable terminated with the DC 2 1 5 5 plug 7 Make the following technical connections when needed ALARM technical output of collective failure indication 8 Check the optical indication of the switch operation 3 Indication of the device operation 3 1 LED indication of operating status The PSU has 6 LED lights at the front panel GREEN LED on the PSU ...

Страница 8: ...ted 10Mb s or 100Mb s YELLOW LED LIGHT LINK The connection status of LAN devices 10MB s or 100Mb s and data transmission OFF no data transmission ON the device is connected 10Mb s or 100Mb s Blinking data transmission 3 3 Technical output The power supply is fitted with the ALARM output of collective failure relay type A collective failure can be triggered by the following events 230V AC mains pow...

Страница 9: ...outage the device is immediately switched into a battery assisted operation The PSU is equipped with the discharged battery disconnection system During the battery assisted operation reducing voltage below 19V at the battery terminals will cause battery disconnection 4 3 Maintenance Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply net...

Страница 10: ...he manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manufacturer exclusively 8 The warranty does not cover the defects of the equipment resulting ...

Отзывы: