WEEE LABEL 

 

Waste electrical and electronic equipment must not be disposed of with normal household 

waste. According to the European Union WEEE Directive, waste electrical and electronic 

equipment should be disposed of separately from normal household waste

 

 

 

 

The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but recycled 

according to the applicable law.

 

 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

GENERAL WARRANTY CONDITIONS 

 

1. Pulsar (manufacturer) grants a two-year quality warranty for the equipment, starting from the production date. 
2. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (selected by the 

manufacturer) if the malfunction is due to the manufacturer. It includes manufacturing or material defects, provided that 
such defects have been reported within the warranty period (point.1). 

3. The equipment subjected to warranty should be brought to the place of purchase or directly to the main office of the 
manufacturer. 

4. The warranty applies to complete equipment, accompanied by a properly filled warranty claim with a description of the 
defect.  

5.  Should the claim be accepted, the manufacturer is obliged to provide warranty repairs, at the earliest convenience, 
however not later that within 14 days from the delivery to the service centre of the manufacturer. 

6.  The repair period mentioned in point 5 may be prolonged, if there are no technical possibilities to carry out the repairs, 
or if the equipment has been conditionally accepted, due to the breaking warranty terms by the claimant. 

7.  All the services are carried out at the service centre of the manufacturer, exclusively. 
8. The warranty does not cover the defects of the equipment, resulting from:  

- reasons beyond the manufacturer's control,  
- mechanical damage,  

- improper storage and transport,  
- use that violates the operation manual or equipment’s intended use  

- fortuitous events, including lightning discharges, power failures, fire, flood, high temperatures and chemical agents,   
- improper installation and configuration (failure to follow instruction). 

9. The warranty is void in case of construction changes and repairs carried out by any unauthorized service center or in 
case of damage or modifications to warranty stickers and serial numbers. 

10. The liability of the manufacturer towards the buyer is limited to the value of the equipment determined according to 
the wholesale prices suggested by the manufacturer on the day of purchase. 

11.  The manufacturer takes no responsibility for the defects that result from the damaging, malfunctioning or inability to 
operate the equipment especially when resulting from failure to comply with the recommendations and requirements 

contained in the manual. 

 

 

Pulsar  

Siedlec 150,  32-744 Łapczyca, Polska 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail: 

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

 

Содержание RSUPS98R

Страница 1: ...RSUPS98R v 1 0 9 port switch for 8 IP cameras IP with battery backup for cameras and recorder RACK mounted EN Edition 1 from 28 06 2016 Supercedes the edition ...

Страница 2: ...data transfer and power supply 15 4W for each PoE port supports devices complaint with the IEEE802 3af standard Supports auto learning and auto aging of MAC addresses 1K size wide range of mains supply AC 176 264V AC battery charging and maintenance control excessive discharging UVP protection battery output protection against short circuit and reverse connection battery charge current 1A voltage ...

Страница 3: ...ating status of the device The switch is fitted with the ALARM technical output of collective failure In the case of failure a LED light is activated which is accompanied by switching of relay contacts and acoustic indication The PoE technology ensures a network connection and reduces installation costs by eliminating the need to supply a separate power cable for each device This method allows sup...

Страница 4: ...position indication OFF PoE port 1 4 for cameras IP connection data power supply PoE port 5 8 for cameras IP connection data power supply UPLINK port for recorder data 230V AC INPUT power socket 230V AC power cable 1 5m included FMAINS fuse in the supply circuit 230V AC T 6 3A 250V Fig 2 The front power of the power supply unit Fig 3 The view of the PSU ...

Страница 5: ...e of 15 4W per port is the maximum value The total power consumption should not exceed 96W when all PoE ports are being used Electrical parameters tab 4 Mains supply 176 264V AC Current up to 1 1A 230V AC max Supply power 172W max Output voltage at the PoE ports Output voltage the recorder NVR 48V DC maintained regardless of the state of battery charge 12V DC maintained regardless of the state of ...

Страница 6: ...out condensation Vibrations during operation unacceptable Impulse waves during operation unacceptable Direct insulation unacceptable Vibrations and impulse waves during transport According to PN 83 T 42106 2 Installation 2 1 Requirements The PSU RACK shall be mounted by a qualified installer with appropriate permissions and qualifications for 230V AC installations and low voltage installations req...

Страница 7: ...f the DVR by default the device is equipped with a cable terminated with the DC 2 1 5 5 plug 7 Make the following technical connections when needed ALARM technical output of collective failure indication 8 Check the optical indication of the switch operation 3 Indication of the device operation 3 1 LED indication of operating status The PSU has 6 LED lights at the front panel GREEN LED on the PSU ...

Страница 8: ...ted 10Mb s or 100Mb s YELLOW LED LIGHT LINK The connection status of LAN devices 10MB s or 100Mb s and data transmission OFF no data transmission ON the device is connected 10Mb s or 100Mb s Blinking data transmission 3 3 Technical output The power supply is fitted with the ALARM output of collective failure relay type A collective failure can be triggered by the following events 230V AC mains pow...

Страница 9: ...outage the device is immediately switched into a battery assisted operation The PSU is equipped with the discharged battery disconnection system During the battery assisted operation reducing voltage below 19V at the battery terminals will cause battery disconnection 4 3 Maintenance Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply net...

Страница 10: ...he manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manufacturer exclusively 8 The warranty does not cover the defects of the equipment resulting ...

Отзывы: