![Pulsar RSUPS98 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/pulsar/rsups98/rsups98_manual_1625231007.webp)
RSUPS98
RACK POWER
7
2.2. Installation procedure.
1. Before installation, cut off the voltage in the 230V power-supply circuit.
2. Mount the power supply in a RACK 19" cabinet as shown below:
- Mount M6 cage nuts
- Secure the enclosure with 4xM6 screws
3. Connect the batteries in series/parallel to the + BAT- terminals:
- battery output (V+): terminal BAT+
- battery output (V-): terminal BAT-
4. Connect the ~230V AC power cord with the IEC C13 plug (included) to the 230V AC power supply and turn on
the power (~230V).
5. Connect the camera cables to the RJ45 connectors (PoE connectors) and connect the recorder to the network
(the UPLINK connector).
6. Make the following technical connections when needed:
ALARM
– technical output of collective failure indication
7. Check the optical indication of the switch operation.
3. Indication of the device operation.
3.1. LED indication of operating status.
The PSU has 5 LED lights at the front panel:
GREEN LED:
on
– the PSU is supplied with 230V AC
off
– no 230V AC supply
GREEN LED:
on
– DC voltage at the output of the switch mode PSU
off
– no DC voltage at the output of the switch mode PSU
RED LED:
on
– failure
off
– no failure
RED LED:
ON
– too high temperature of the switch mode power supply
(>70°C)
OFF
– standard temperature of the switch mode power supply
RED LED:
on
– battery voltage <23V
off
– battery voltage >23V