background image

www.pulsar.pl

    

 

 

 

RSUPS98 

 

 

  

            

RACK POWER 

 

 

 

 

Example of use. 

 

 
CONTENTS: 
1. Technical description. 

1.1. General description 
1.2. Block diagram 
1.3. Description of components and connectors 
1.4. Specifications 

2. Installation. 

2.1. Requirements 
2.2. Installation procedure 

3. Indication of the device operation. 

3.1. LED indication of operating status 
3.2. Optical indication of the switch operation 
3.3. Technical output 
3.4. Acoustic indication 

4. Operation and use. 

4.1. Overload or short circuit of the PSU output 
4.2. Battery-assisted operation 

 

4.3. Maintenance 

Features: 

 

 

Uninterruptible power supply of 8 IP cameras 
(48VDC)  

 

9 10/100 Mb/s ports  

 

8 PoE ports (data transfer and power supply) 

 

15,4W for each PoE port, supports devices 
complaint with the IEEE802.3af standard 

 

Supports auto-learning and auto-aging of MAC 
addresses (1K size) 

 

wide range of mains supply AC

: 176÷264V AC 

 

battery charging and maintenance control 

 

excessive discharging (UVP) protection 

 

battery output protection against short circuit  and 
reverse connection 

 

battery charge current: 0,5A

 

  acoustic indication of failure  

  LED optical indication: AC, DC, TEMP, LoB, ALARM 

  the ALARM technical output of collective failure 

– 

relay type, activated by:  

  230V AC power loss 

  low voltage of the PSU (<23V) 

  too high temperature of the PSU 

(>70°C) 

  the PSU failure  

  protections: 

  SCP short-circuit protection 

  overvoltage protection 

  overload protection OLP 

  forced cooling (fan) 

  warranty – 2 year from the production date 

Содержание RSUPS98

Страница 1: ...RSUPS98 v 1 0 9 port switch for 8 IP cameras IP with battery backup for cameras RACK mounted EN Edition 1 from 28 06 2016 Supercedes the edition ...

Страница 2: ...ports 8 PoE ports data transfer and power supply 15 4W for each PoE port supports devices complaint with the IEEE802 3af standard Supports auto learning and auto aging of MAC addresses 1K size wide range of mains supply AC 176 264V AC battery charging and maintenance control excessive discharging UVP protection battery output protection against short circuit and reverse connection battery charge c...

Страница 3: ...itch is fitted with the ALARM technical output of collective failure In the case of failure a LED light is activated which is accompanied by switching of relay contacts and acoustic indication The PoE technology ensures a network connection and reduces installation costs by eliminating the need to supply a separate power cable for each device This method allows supplying other network devices such...

Страница 4: ...ation ON switch in the down position indication OFF PoE port 1 8 for cameras IP connection data power supply UPLINK port for recorder data 230V AC INPUT power socket 230V AC power cable 1 5m included FMAINS fuse in the supply circuit 230V AC T 3 15A 250V Fig 2 The front power of the power supply unit Fig 3 The view of the PSU ...

Страница 5: ...ward Optical indication of operation Switch power supply Link Act PoE Status The given value of 15 4W per port is the maximum value The total power consumption should not exceed 96W when all PoE ports are being used Electrical parameters tab 4 Mains supply 176 264V AC Current up to 1 1A 230V AC max Supply power 110W max Output voltage at the PoE ports 48V DC maintained regardless of the state of b...

Страница 6: ... waves during operation unacceptable Direct insulation unacceptable Vibrations and impulse waves during transport According to PN 83 T 42106 2 Installation 2 1 Requirements The PSU RACK shall be mounted by a qualified installer with appropriate permissions and qualifications for 230V AC installations and low voltage installations required and necessary for a given country The device shall be mount...

Страница 7: ...onnectors and connect the recorder to the network the UPLINK connector 6 Make the following technical connections when needed ALARM technical output of collective failure indication 7 Check the optical indication of the switch operation 3 Indication of the device operation 3 1 LED indication of operating status The PSU has 5 LED lights at the front panel GREEN LED on the PSU is supplied with 230V ...

Страница 8: ...on ON the device is connected 10Mb s or 100Mb s YELLOW LED LIGHT LINK The connection status of LAN devices 10MB s or 100Mb s and data transmission OFF no data transmission ON the device is connected 10Mb s or 100Mb s Blinking data transmission 3 3 Technical output The power supply is fitted with the ALARM output of collective failure relay type A collective failure can be triggered by the followin...

Страница 9: ...utage the device is immediately switched into a battery assisted operation The PSU is equipped with the discharged battery disconnection system During the battery assisted operation reducing voltage below 19V at the battery terminals will cause battery disconnection 4 3 Maintenance Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply netw...

Страница 10: ...he manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manufacturer exclusively 8 The warranty does not cover the defects of the equipment resulting ...

Отзывы: