Mechanical parameters (tab. 5). 

Enclosure dimensions 

W=19”, H=2U; 482 x 88 x 265  mm (WxHxD) 

Fixation 

four-point butt mounting to RACK profiles 

– the set include 4 M6 cage nuts 

Net weight 

6,36kg / 6,88kg  

Enclosure 

Steel plate RAL 9005, black 

Connectors 

230V AC input: the IEC C14 socket with a fuse, power cable 1,5m  
(included) 
Technical output 

ALARM

: Φ0,5-2,1 (AWG 24-12) 0,5-1,5mm

2

 

Outputs of cameras

 PoE

: sockets RJ45 8P8C 

Data output of the 

UPLINK

 recorder: RJ45 8P8C jack 

Battery output 

BAT

: 6,3F-2,5 

Notes 

Forced cooling (fan). 

       

Operation safety (tab.6). 

Protection class PN-EN 60950-1:2007 

I (first) 

Protection grade PN-EN 60529: 2002 (U) 

IP20 

Electrical strength of insulation: 
- between input and output circuits of the PSU (I/P-O/P) 
- between input circuit and PE protection circuit (I/P-FG) 
- between output circuit and PE protection circuit (O/P-FG) 

 
3000 V/AC min. 
1500 V/AC min. 
  500 V/AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 
100 MΩ, 500V/DC  

Operating parameters (tab.7). 

Environmental class 

II 

Operating temperature 

-

10ºC...+45ºC 

Storage temperature 

-

20ºC...+60ºC 

Relative humidity 

20%...90%, without condensation 

Vibrations during operation 

unacceptable 

Impulse waves during operation 

unacceptable 

Direct insulation 

unacceptable 

Vibrations and impulse waves during transport 

According to PN-83/T-42106 

 

 
2.  Installation. 
 

2.1.  Requirements. 

The PSU RACK shall be mounted by a qualified installer with appropriate permissions and qualifications for 

230V/AC installations and low-voltage installations (required and necessary for a given country). The device shall 
be  mounted  in  confined  spaces,  according  to  the  environment  class  II,  with  normal  air  humidity  (RH=90%  max. 
without condensation) and the temperature from -

10°C do +45°C.  

 
Before installation, prepare a Switch'a load balance.  
 

The  given  value  of  15,4W  per  port  is  the  maximum  value  referring  to  a  single  output.  The  total 

power consumption should not exceed  96W when all PoE ports  are being used

. The increased demand for 

power  is  particularly  evident  in  the  case  of  cameras  with  heaters  or  infrared  illuminators  -  when  launching  these 
features, the power consumption increases rapidly, which may adversely affect the operation of the switch. 

As the PSU is designed for a continuous operation and is not equipped with a power-switch, therefore an 

appropriate  overload  protection  shall  be  guaranteed  in  the  power  supply  circuit.  Moreover,  the  user  shall  be 
informed  about  the  method  of  unplugging  (usually  through  assigning  an  appropriate  fuse  in  the  fuse-box).  The 
electrical system shall follow valid standards and regulations.  

 
 
 
 
 
 
 
 
 
 
 
 

Содержание RSUPS98

Страница 1: ...RSUPS98 v 1 0 9 port switch for 8 IP cameras IP with battery backup for cameras RACK mounted EN Edition 1 from 28 06 2016 Supercedes the edition ...

Страница 2: ...ports 8 PoE ports data transfer and power supply 15 4W for each PoE port supports devices complaint with the IEEE802 3af standard Supports auto learning and auto aging of MAC addresses 1K size wide range of mains supply AC 176 264V AC battery charging and maintenance control excessive discharging UVP protection battery output protection against short circuit and reverse connection battery charge c...

Страница 3: ...itch is fitted with the ALARM technical output of collective failure In the case of failure a LED light is activated which is accompanied by switching of relay contacts and acoustic indication The PoE technology ensures a network connection and reduces installation costs by eliminating the need to supply a separate power cable for each device This method allows supplying other network devices such...

Страница 4: ...ation ON switch in the down position indication OFF PoE port 1 8 for cameras IP connection data power supply UPLINK port for recorder data 230V AC INPUT power socket 230V AC power cable 1 5m included FMAINS fuse in the supply circuit 230V AC T 3 15A 250V Fig 2 The front power of the power supply unit Fig 3 The view of the PSU ...

Страница 5: ...ward Optical indication of operation Switch power supply Link Act PoE Status The given value of 15 4W per port is the maximum value The total power consumption should not exceed 96W when all PoE ports are being used Electrical parameters tab 4 Mains supply 176 264V AC Current up to 1 1A 230V AC max Supply power 110W max Output voltage at the PoE ports 48V DC maintained regardless of the state of b...

Страница 6: ... waves during operation unacceptable Direct insulation unacceptable Vibrations and impulse waves during transport According to PN 83 T 42106 2 Installation 2 1 Requirements The PSU RACK shall be mounted by a qualified installer with appropriate permissions and qualifications for 230V AC installations and low voltage installations required and necessary for a given country The device shall be mount...

Страница 7: ...onnectors and connect the recorder to the network the UPLINK connector 6 Make the following technical connections when needed ALARM technical output of collective failure indication 7 Check the optical indication of the switch operation 3 Indication of the device operation 3 1 LED indication of operating status The PSU has 5 LED lights at the front panel GREEN LED on the PSU is supplied with 230V ...

Страница 8: ...on ON the device is connected 10Mb s or 100Mb s YELLOW LED LIGHT LINK The connection status of LAN devices 10MB s or 100Mb s and data transmission OFF no data transmission ON the device is connected 10Mb s or 100Mb s Blinking data transmission 3 3 Technical output The power supply is fitted with the ALARM output of collective failure relay type A collective failure can be triggered by the followin...

Страница 9: ...utage the device is immediately switched into a battery assisted operation The PSU is equipped with the discharged battery disconnection system During the battery assisted operation reducing voltage below 19V at the battery terminals will cause battery disconnection 4 3 Maintenance Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply netw...

Страница 10: ...he manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manufacturer exclusively 8 The warranty does not cover the defects of the equipment resulting ...

Отзывы: