background image

www.pulsar.pl

    

 

 

 

RSFUPS108 

 

 

 

            

RACK POWER 

 

 

1.  Technical description. 
 

1.1.  General description. 

            The  RSFUPS108  is  a  complete  solution  for  power  supply  and  battery  backup  of  8  IP  cameras  (48VDC  power 
supply) in 

RACK

 19" standard. 

 
The main elements of this system include: 

- 10 ports PoE switch 
- buffer power supply 27,6V unit which can accommodate two 12V batteries 
- a converter (DC/DC48250) increasing the voltage to 48VDC (supply of the PoE switch) 

 

In  case  of  mains  power  loss,  a  battery  back-up  is  activated  immediately.  Automatic  detection  of  any  devices 

powered in the PoE standard is enabled at the 1 

– 8 ports of the switch. The G1/TP, G2/TP ports is used for connection 

of another network device via RJ45 connector. The switch is fitted with SFP slots  (marked as G1/SFP and G2/SFP); the 
use of fiber optic module (GBIC) allows fiber optic transmission. The LED lights at the front panel indicate the operating 
status of the device. 

 
The  switch  is  fitted  with  the  ALARM  technical  output  of  collective  failure.  In  the  case  of  failure,  a  LED  light  is 

activated, which is accompanied by switching of relay contacts and acoustic indication. 

 

The  PoE  technology  ensures  a  network  connection  and  reduces  installation  costs  by  eliminating  the  need  to 

supply a separate power cable for each device. This method allows supplying other network devices, such as IP phone, 
wireless access point or router. 

 

1.2.  Block diagram. 

 

 

 

Fig.1. The block diagram of the PSU. 

 
1.3.  Description of components and connectors. 
 

Table 1. (See Fig. 2, 3) 

Element no. 

 [Fig. 2] 

Description 

 

AC

 

OK

 

– green LED, indicating the presence of 230V voltage 

 

DC

 

OK

 

– green LED, indicating the presence of DC voltage

 

 

TEMP 

– red LED, indicating too high temperature of the power supply (>70°C)

 

 

LoB 

– red LED, indicating too low battery voltage (<23V)

 

 

LED ALARM 

– red LED collective failure indication

 

 

BAT 

– battery output 

 

ALARM 

– technical output of collective failure – relay

 

Содержание Rack Power RSFUPS108

Страница 1: ...RSFUPS108 v 1 0 10 ports switch with buffer power supply for 8 IP cameras RACK mounted EN Edition 1 from 22 09 2017 Supercedes the edition ...

Страница 2: ...d power supply 2 ports 10 100 1000Mb s ports G1 TP G2 TP UpLink 2 ports 10 100 1000 Mb s SFP G1 SFP G2 SFP ports 15 4W for each PoE port supports devices complaint with the IEEE802 3af standard Supports auto learning and auto aging of MAC addresses 1K size battery charging and maintenance control excessive discharging UVP protection battery output protection against short circuit and reverse conne...

Страница 3: ...The LED lights at the front panel indicate the operating status of the device The switch is fitted with the ALARM technical output of collective failure In the case of failure a LED light is activated which is accompanied by switching of relay contacts and acoustic indication The PoE technology ensures a network connection and reduces installation costs by eliminating the need to supply a separate...

Страница 4: ...ion indication OFF PoE port 1 8 for cameras IP connection data power supply 2 x UPLINK ports G1 TP G2 TP 2 x UPLINK ports G1 SFP G2 SFP 230V AC INPUT power socket 230V AC power cable 1 5m included FMAINS fuse in the supply circuit 230V AC T 3 15A 250V Fig 2 The front power of the power supply unit Fig 3 Rear panel of the power supply Fig 4 The view of the PSU ...

Страница 5: ...2 3af 1 8 ports 48VDC 15 4W at each port Protocols Standards IEEE802 3 802 3u 802 3x CSMA CD TCP IP Forwarding rate 10BASE T 14880pps port 100BASE TX 148800pps port Bandwidth 1 6Gbps Transmission method Store and Forward Optical indication of operation Switch power supply Link Act PoE Status The given value of 15 4W per port is the maximum value The total power consumption should not exceed 96W wh...

Страница 6: ...DC Operating parameters tab 7 Environmental class II Operating temperature 10ºC 40ºC Storage temperature 20ºC 60ºC Relative humidity 20 90 without condensation Vibrations during operation unacceptable Impulse waves during operation unacceptable Direct insulation unacceptable Vibrations and impulse waves during transport According to PN 83 T 42106 2 Installation 2 1 Requirements The PSU RACK shall ...

Страница 7: ...nnectors and connect the recorder to the network the UPLINK connector 6 Make the following technical connections when needed ALARM technical output of collective failure indication 7 Check the optical indication of the switch operation 3 Indication of the device operation 3 1 LED indication of operating status The PSU has 5 LED lights at the front panel GREEN LED on the PSU is supplied with 230V A...

Страница 8: ...mission CAUTION The operating status of the G1 TP G1 SFP G2 TP and G2 SFP slots is shown on the LEDs located near the RJ45 connector see below CAUTION G1 TP and G1 SFP or G2 TP and G2 SFP sockets can not operate simultaneously These are COMBO type sockets GREEN LED LIGHT SPEED OFF connection 10Mb s or 100Mb s ON connection 1000Mb s CAUTION The operating status of the G1 TP G1 SFP G2 TP and G2 SFP ...

Страница 9: ...restoration of the voltage takes place immediately once the failure overload is over 4 2 Battery assisted operation In case of a main power outage the device is immediately switched into a battery assisted operation The PSU is equipped with the discharged battery disconnection system During the battery assisted operation reducing voltage below 19V at the battery terminals will cause battery discon...

Страница 10: ...and electronic equipment should be disposed of separately from normal household waste The power supply unit is adapted for a sealed lead acid battery SLA After the operation period it must not be disposed of but recycled according to the applicable law Pulsar Siedlec 150 32 744 Łapczyca Polska Tel 48 14 610 19 40 Fax 48 14 610 19 50 e mail biuro pulsar pl sales pulsar pl http www pulsar pl www zas...

Отзывы: