background image

www.pulsar.pl

    

 

 

 

RSFUPS108 

 

 

  

            

RACK POWER 

 

 

Battery circuit protection SCP and reverse 
polarity connection 

melting fuse 

Excessive discharge protection UVP 

U<19V (+/-5%) 

– disconnect of connection battery 

Optical indication of operation: 

LED: AC, DC, TEMP, LoB, ALARM, LINK, PoE 

Acoustic operation indication: 

Piezoelectric indicator ~75dB/0,3m 

The ALARM technical output of collective failure 

Relay type: 1A@ 30VDC/50VAC 

The 

F

MAINS

 

fuse in the 230V power supply circuit 

T 3,15A 

        
        

Mechanical parameters (tab. 5). 

Enclosure dimensions 

W=19”, H=2U; 482 x 88 x 324  [mm] (±2) (WxHxD) 

Fixation 

four-point butt mounting to RACK profiles 

– the set include 4 M6 cage nuts 

Net weight 

7,3kg / 7,9kg 

  

Enclosure 

Steel plate RAL 9005, black 

Connectors 

230V AC

 input: the IEC C14 socket with a fuse, power cable 1,5m  

(included) 
Technical output 

ALARM

Φ0,5-2,1 (AWG 24-12) 0,5-1,5mm

2

 

Outputs of cameras

 PoE

: sockets RJ45 8P8C 

Data output of the 

UPLINK

 recorder: RJ45 8P8C jack 

Battery output 

BAT

: 6,3F-2,5 

Notes 

Forced cooling (fan). 

        
       

Operation safety (tab.6). 

Protection class PN-EN 60950-1:2007 

I (first) 

Protection grade PN-EN 60529: 2002 (U) 

IP20 

Electrical strength of insulation: 
- between input and output circuits of the PSU (I/P-O/P) 
- between input circuit and PE protection circuit (I/P-FG) 
- between output circuit and PE protection circuit (O/P-FG) 

 
3000 V/AC min. 
1500 V/AC min. 
  500 V/AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 
100 MΩ, 500V/DC  

 
 Operating parameters (tab.7). 

Environmental class 

II 

Operating temperature 

-

10ºC...+40ºC 

Storage temperature 

-

20ºC...+60ºC 

Relative humidity 

20%...90%, without condensation 

Vibrations during operation 

unacceptable 

Impulse waves during operation 

unacceptable 

Direct insulation 

unacceptable 

Vibrations and impulse waves during transport 

According to PN-83/T-42106 

 
2.  Installation. 
 

2.1.  Requirements. 

The PSU RACK shall be mounted by a qualified installer with appropriate permissions and qualifications for 

230V/AC installations and low-voltage installations (required and necessary for a given country). The device shall 
be  mounted  in  confined  spaces,  according  to  the  environment  class  II,  with  normal  air  humidity  (RH=90%  max. 
without condensation) and the temperature from -

10°C do +40°C.  

 
Before installation, prepare a Switch'a load balance.  
 

The  given  value  of  15,4W  per  port  is  the  maximum  value  referring  to  a  single  output.  The  total 

power consumption should not exceed  96W when all PoE ports  are being used

. The increased demand for 

power  is  particularly  evident  in  the  case  of  cameras  with  heaters  or  infrared  illuminators  -  when  launching  these 
features, the power consumption increases rapidly, which may adversely affect the operation of the switch. 

As the PSU is designed for a continuous operation and is not equipped with a power-switch, therefore an 

appropriate  overload  protection  shall  be  guaranteed  in  the  power  supply  circuit.  Moreover,  the  user  shall  be 
informed  about  the  method  of  unplugging  (usually  through  assigning  an  appropriate  fuse  in  the  fuse-box).  The 
electrical system shall follow valid standards and regulations.  

 

 

 

Содержание Rack Power RSFUPS108

Страница 1: ...RSFUPS108 v 1 0 10 ports switch with buffer power supply for 8 IP cameras RACK mounted EN Edition 1 from 22 09 2017 Supercedes the edition ...

Страница 2: ...d power supply 2 ports 10 100 1000Mb s ports G1 TP G2 TP UpLink 2 ports 10 100 1000 Mb s SFP G1 SFP G2 SFP ports 15 4W for each PoE port supports devices complaint with the IEEE802 3af standard Supports auto learning and auto aging of MAC addresses 1K size battery charging and maintenance control excessive discharging UVP protection battery output protection against short circuit and reverse conne...

Страница 3: ...The LED lights at the front panel indicate the operating status of the device The switch is fitted with the ALARM technical output of collective failure In the case of failure a LED light is activated which is accompanied by switching of relay contacts and acoustic indication The PoE technology ensures a network connection and reduces installation costs by eliminating the need to supply a separate...

Страница 4: ...ion indication OFF PoE port 1 8 for cameras IP connection data power supply 2 x UPLINK ports G1 TP G2 TP 2 x UPLINK ports G1 SFP G2 SFP 230V AC INPUT power socket 230V AC power cable 1 5m included FMAINS fuse in the supply circuit 230V AC T 3 15A 250V Fig 2 The front power of the power supply unit Fig 3 Rear panel of the power supply Fig 4 The view of the PSU ...

Страница 5: ...2 3af 1 8 ports 48VDC 15 4W at each port Protocols Standards IEEE802 3 802 3u 802 3x CSMA CD TCP IP Forwarding rate 10BASE T 14880pps port 100BASE TX 148800pps port Bandwidth 1 6Gbps Transmission method Store and Forward Optical indication of operation Switch power supply Link Act PoE Status The given value of 15 4W per port is the maximum value The total power consumption should not exceed 96W wh...

Страница 6: ...DC Operating parameters tab 7 Environmental class II Operating temperature 10ºC 40ºC Storage temperature 20ºC 60ºC Relative humidity 20 90 without condensation Vibrations during operation unacceptable Impulse waves during operation unacceptable Direct insulation unacceptable Vibrations and impulse waves during transport According to PN 83 T 42106 2 Installation 2 1 Requirements The PSU RACK shall ...

Страница 7: ...nnectors and connect the recorder to the network the UPLINK connector 6 Make the following technical connections when needed ALARM technical output of collective failure indication 7 Check the optical indication of the switch operation 3 Indication of the device operation 3 1 LED indication of operating status The PSU has 5 LED lights at the front panel GREEN LED on the PSU is supplied with 230V A...

Страница 8: ...mission CAUTION The operating status of the G1 TP G1 SFP G2 TP and G2 SFP slots is shown on the LEDs located near the RJ45 connector see below CAUTION G1 TP and G1 SFP or G2 TP and G2 SFP sockets can not operate simultaneously These are COMBO type sockets GREEN LED LIGHT SPEED OFF connection 10Mb s or 100Mb s ON connection 1000Mb s CAUTION The operating status of the G1 TP G1 SFP G2 TP and G2 SFP ...

Страница 9: ...restoration of the voltage takes place immediately once the failure overload is over 4 2 Battery assisted operation In case of a main power outage the device is immediately switched into a battery assisted operation The PSU is equipped with the discharged battery disconnection system During the battery assisted operation reducing voltage below 19V at the battery terminals will cause battery discon...

Страница 10: ...and electronic equipment should be disposed of separately from normal household waste The power supply unit is adapted for a sealed lead acid battery SLA After the operation period it must not be disposed of but recycled according to the applicable law Pulsar Siedlec 150 32 744 Łapczyca Polska Tel 48 14 610 19 40 Fax 48 14 610 19 50 e mail biuro pulsar pl sales pulsar pl http www pulsar pl www zas...