Pulsar QUANTUM HSQ 19 Скачать руководство пользователя страница 8

9

8

TROUBLESHOOTING

13

Listed below are some potential problems that may occur when using the 
scope. Carry out the recommended checks and troubleshooting steps in 
the order listed. Please note that the table does not list all of the possible 

problem

possible cause

corrective action 

The unit will 
not turn on.

The  image  is  blurry,  with 
vertical stripes and uneven 
background. 

The image is too dark. 

Batteries have been wrongly
installed.  

Oxidized contact points in the 
battery  compartment  due  to 
“leaky”  batteries  or  contact 
points  becoming  exposed  to 
a chemically reactive solution. 

The batteries are fully 
exhausted.

Calibration is to be done.

The lowest brightness level 
is set. 

Reinstall the batteries observing polarity. 

Clean the battery compartment,  
focusing on the contacts. 

Install fresh batteries.

Do the calibration according to section 

8 “OPERATION”

Adjust brightness by rotating the 
encoder 

(5)

Select a suitable video output standard - PAL or NTSC (refer to section 

“MENU”

).

Use  the  included  video  cable  to  connect  a  peripheral  device  to  the 

“Video out”

 jack 

(11)

Switch on your thermal imaging scope – a peripheral device will show 
the image seen through the scope. 

Battery packs 

EPS3/EPS5

 (SKU#79111/79112) 

CVR640

 video recorder (SKU#17044) and others. 

ACCESSORIES

11

Using the Weaver mounting rail 

(8)

, you can attach various accessories to 

the 

Quantum

 scopes, such as: 

The ¼” tripod mounts from both sides of the scope are designed to have 
the scope installed on a tripod or have a hand strap (included) attached. 

CARE AND MAINTENANCE

12

The thermal imaging scopes have IPX4 degree of protection (protected 
against splash water) but they are not intended for submersion into 
water. 
Attempts to disassemble or repair the scope will void the warranty! 
Clean the scope's optical surfaces only if necessary, and use caution. 
First, remove (by blowing with a blower brush or canned air) any dust or 
sand particles. Then proceed to clean by using camera/lens cleaning 
equipment approved for use with multicoated lenses. 

Do not pour the 

solution directly onto the lens! 

The scope can be used in operating temperatures ranging from
-20 °C to +50 °C. However, if it has been brought indoors from cold 
temperatures, do not turn it on for three to four hours. This will prevent 
external optical surfaces from fogging. 
Always store the unit in its carrying case in a dry, well-ventilated space.  
Remove  the  batteries  if  the  scope  is  not  going  to  be  used  for  an 
extended period (longer than one month).
Batteries shall not be exposed to excessive heat such as sunshine, fire 
or the like.

 problems. If the problem experienced with the scope is not listed, or if the 
suggested  action  meant  to  correct  it  does  not  resolve  the  problem, 
please contact the manufacturer.

The FPAs (focal plane arrays) by ULIS employed in Quantum thermal scopes feature high 
quality but the manufacturer allows a certain amount of non-operating pixels. Such pixels 
are not a defect and foreseen in regulations of the array manufacturer.

A non-operating pixel

 is defined as a black or luminous dot. 

A cluster 

is defined as a group of several non-operating pixels adjacent by side or corner. 

Central area A

 is defined as an area with a size of ¼ of the total length and width of the 

image.

Peripheral area B

 is defined as part of the image excluding the central area.

 
For the 160x120 array (models Quantum HS19, LS19):

Not more than four non-operating pixels or one cluster consisting of not more than 
four non-operating pixels are accepted in the central area.
Not more than nine non-operating pixels or one cluster consisting of not more than 
nine non-operating pixels are accepted in the peripheral area.

For the 384x288 array (models Quantum HD38, LD38):

Four single non-operating pixels or not 
more than two clusters consisting of 
not more than two non-operating 
pixels are accepted in the central area.
Ten single non-operating pixels or not 
more than two clusters consisting of 
not more than ten non-operating pixels 
are accepted in the peripheral area.

A

B

Содержание QUANTUM HSQ 19

Страница 1: ...QUANTUM THERMAL IMAGING SCOPE...

Страница 2: ......

Страница 3: ......

Страница 4: ...2 9 10 17 18 25 26 33 34 41 42 49 THERMAL IMAGING SCOPE QUANTUM QUANTUM THERMOVISEUR QUANTUM W RMEBILDGER T QUANTUM T RMOVISOR QUANTUM TERMOVISORE QUANTUM v 1012...

Страница 5: ...etc Unlike the image intensifier tube based night vision devices thermal imaging scopes Quantum do not require an external source of light and are not affected by bright light exposure Thermal imagin...

Страница 6: ...2 A B C D E F G H 24 16 12 x2 16 12 DATA PANEL ICONS 2 6 7 8 4 5 3 1 10 9 14 12 11 13 15 Lens cap storage hole 15 Turn the lever of the battery compartment 12 90 degrees in Open position and pulling b...

Страница 7: ...9 to 20 hours of operation The scope can be powered with an external DC power supply 2 1mm pin with stabilised voltage ranging from 8 4V to 15V max consumption power 3W or a 12V vehicle socket Press...

Страница 8: ...Then proceed to clean by using camera lens cleaning equipment approved for use with multicoated lenses Do not pour the solution directly onto the lens The scope can be used in operating temperatures r...

Страница 9: ...ptiques les monoculaires de thermoviseurs Quantum ne n cessitent pas de source de lumi re externe et ne craignent pas l exposition la lumi re Les thermoviseurs Quantum peuvent tre utilis s au cours de...

Страница 10: ...sortie B C D E F G H 12 00 00 AM x2 A B C D E F G H 24 16 12 x2 16 12 ELEMENTS DU VISEUR ET ORGANES DE COMMANDE Place pour fixer le couvercle de l objectif 15 2 6 7 8 4 5 3 1 10 9 14 12 11 13 15 Tour...

Страница 11: ...R gler la valeur heure minute l aide de la rotation de l encoder Pour quitter le menu maintenez l encoder 5 appuy pendant deux secondes Fonction Heures Une source ext rieure d alimentation AC DC doit...

Страница 12: ...ent et en cas d une vraie n cessit D abor enlevez avec precaution souffler ou secouer la poussi re et la boue de la surface optique puis faites le nettoyage Utilisez pour cela une serviette coton ouat...

Страница 13: ...Lichtverst rkerr hre dadurch dass sie keine Zusatzbeleuchter brauchen und gegen helles Licht widerstandsf hig sind Die Anwendungsbereiche der Ger te Quantum umfassen Nachtjagd Beobachtung Orientierun...

Страница 14: ...rzeiteinstellung Digitales Zoom 2x A Umschalten des Ausgangsvideosignals PAL NTSC B C D E F G H 12 00 00 AM x2 A B C D E F G H 24 16 12 x2 16 12 PIKTOGRAMME DER ANZEIGETAFEL 2 6 7 8 4 5 3 1 10 9 14 12...

Страница 15: ...e Kontraststufe von 1 bis 20 wird neben dem Kontrastanzeiger auf der Informationstafel gezeigt W hlen Sie einen unbeweglichen warmen Beobachtungsobjekt der 100 Meter entfernt ist Bildfokussierung und...

Страница 16: ...Ger t zu reparieren und zu demontieren Reinigen Sie die optischen Au enteile sehr vorsichtig und nur im Falle der dringenden Notwendigkeit Zuerst entfernen wischen oder abst uben Sie vorsichtig den St...

Страница 17: ...tos de visi n nocturna sobre la base de convertidores electr nico pticos los monoculares termovisores Quantum no necesitan una fuente externa de luz y no temen a las sobreexposiciones Los termovisores...

Страница 18: ...C D E F G H 24 16 12 x2 16 12 CONOS DEL TABLERO DE INFORMACI N 12 00 00 AM x2 A B C D E F G H El sitio para fijar la tapa del objetivo 15 2 6 7 8 4 5 3 1 10 9 14 12 11 13 15 Gire la manilla de la tap...

Страница 19: ...inutos Para salir del men mantenga presionado el encoder 5 en el curso de dos segundos La funci n Reloj La fuente externa de alimentaci n AC DC se debe conectar al enchufe Power 14 que se encuentra en...

Страница 20: ...r as en correspondencia con la marcaci n Limpie el contenedor de las bater as limpie los contactos Coloque bater as cargadas Lleve a cabo la calibraci n de la imagen de acuerdo con las instrucciones d...

Страница 21: ...rtitori elettro ottici i monoculari termovisivi Quantum non hanno bisogno della fonte esterna della luce e non temono delle esposizioni alla luce I termovisori Quantum possono essere usati durante la...

Страница 22: ...do l encoder 5 regolarizzare il significato di ora minuti Per tornarsi nel MENU trattenete premendo l encoder 5 per 2 secondi Funzione Orologio L alimentatore esterno AC DC deve essere collegato alla...

Страница 23: ...ambio di videosegnale di uscita B C D E F G H 24 16 12 x2 16 12 PICTOGRAMMI DI PANELLO INFORMATIVO 12 00 00 AM x2 A B C D E F G H Posto per fissare il coperchio dell obiettivo 15 2 6 7 8 4 5 3 1 10 9...

Страница 24: ...terie cariche Fare la calibratura dell immagine secondo le istruzioni del paragrafo 8 Istruzioni sul uso Regolare la luminosit girando l encoder 5 Scegliere nel menu il formato necessario del videoseg...

Страница 25: ...0 31 2 5 5 450 8 4 15 IP 4 2 1 2 1 2 5 2 5 8 8 8 8 10 10 10 10 9 20 9 20 9 20 9 20 PAL NTSC PAL NTSC PAL NTSC PAL NTSC 470 560 470 560 400 490 400 490 200x86x59 200x86x59 177x86x58 177x86x58 Quantum...

Страница 26: ...5 45 44 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 ON CAL ZOOM INVERT Weaver White hot Black hot 2x A B C D E F G H 12 00 00 AM x2 A B C D E F G H 24 16 12 x2 16 12 2 6 7 8 4 5 3 1 10 9 14 12 11 13 15...

Страница 27: ...46 47 ON 1 14 CAL 2 1 2 CALIBRATION 8 6 13 6 ZOOM INVERT 3 White hot Black hot ZOOM INVERT 3 160x120 White hot Black hot ON 1 9 5 5 5 24 AM PM 5 5 5 4 15 13 5 1 20 5 1 20 100 5 5 PAL NTSC 5 5 10...

Страница 28: ...49 48 EPS3 EPS5 CVR640 11 Weaver 8 Quantum 20 C 50 C 2 3 12 c 8 5 IPX4 ULIS Quantum 160x120 Quantum HS19 LS19 384x288 Quantum HD38 LD38 A B...

Отзывы: