2. Installation. 

 

2.1 Requirements. 

The buffer PSU is to be mounted by a qualified installer, holding relevant permits and licenses (applicable 

and  required  for  a  given  country)  for  230V  AC  interference  and  low-voltage  installations.  The  unit  should  be 
mounted  in  confined  spaces,  in  accordance  with  the  2nd  environmental  class,  with  normal  relative  humidity 
(RH=90% maximum, without condensation) and temperature from -

10°C to +40°C. The PSU shall work in a vertical 

position that guarantees sufficient convectional air-flow through ventilating holes of the enclosure.  

 

                          The power supply load balance should be done before installation:   

                         1.   Output current 16x0,8A + 5A re 2A battery charging

*

 

                         2.   Output current 16x0,7A + 5A re 4A battery charging

                                         3.   Output current 16x0,4A + 5A re 8A battery charging

 
                                  Total current of the rec battery 20A

*

 

max. 

 

As the PSU is designed for a continuous operation and is not equipped with a power-switch, therefore an 

appropriate  overload  protection  shall  be  guaranteed  in  the  power  supply  circuit.  Moreover,  the  user  shall  be 
informed about the method of unplugging (most frequently through separating and assigning an appropriate fuse in 
the fuse-box). The electrical system shall follow valid standards and regulations.  

 

2.2 Installation procedure. 

 

1. Before installation, make sure that the voltage in the 230V power-supply circuit is cut off. 

2. Mount the PSU in a selected location and connect the wires. 
3.  Connect  the  power  cables  (~230V  AC)  to  L-N  terminals  of  the  PSU.  Connect  the  ground  wire  to  the  terminal 

marked  by  the  earth  symbol 

– “

” on the plate. Use a three-core cable (with a  yellow and green  PE protection 

wire)  to  make  the  connection.  Lead  the  cables  to  the  appropriate  terminals  of  the  connection  board  through  the 
bushing.  

 

The shock protection circuit shall be performed with a particular care, i.e. the yellow and green 
wire  coat  of  the  power  cable  shall  stick  to  one  side  of  the  terminal 

marked  with  the  ‘

’  earth 

symbol in the PSU  enclosure.  Operation of the power supply without a properly made and fully 
operational  shock  protection  circuit  is  UNACCEPTABLE!  It  can  result  in  device  damage  or  an 
electric shock

.  

 

 
4. Connect the power supply of the DVR (by default, the device is equipped with a cable terminated with the DC 2.1 
/ 5.5 plug). 
5. Connect the camera cables to the 

AUX1…AUX16

 connectors of the LB8 modules. 

6. Connect the power (~230V). 
7. Check the PSU output voltage: 
- the PSU voltage without load should amount to U=13,8V DC.  
8. Connect the battery (mind the colours):   
- battery output (+):  BAT+ cable / red, 
- battery output (-):  BAT 

– cable / GND / black. 

9. Check the PSU operation indicator: green LED on the power supply module. 
10. After installing and checking proper working, the enclosure can be closed.  
 
 
 
 
 
 
 
 
 
 
 
 

 
 

                                                 

*

 

See chart 1

 

Содержание PSUPS20A12E

Страница 1: ...PSUPS20A12E v 1 2 PSUPS 13 8V 12V 20A 65Ah Buffer power supply for 16 HD cameras and recorder EN Edition 5 from 15 11 2017 Supercedes the edition 4 from 20 04 2017 GREEN POWER CCTV...

Страница 2: ...output protection against short circuit and reverse polarity connection LED indication protections SCP short circuit protection OLP overload protection OVP over voltage protection OHP overheat protec...

Страница 3: ...ity consumption for own needs and the energy efficiency of the power intake track were taken into account The exact description of how to perform the calculations can be found at Approximate backup ti...

Страница 4: ...onent no Fig 4 Description PSU module PSB 30012200 Connectors of the PSU L N 230V AC power connector PE protection connector V V DC supply outputs B B battery output green LED indicates DC power P1 po...

Страница 5: ...www pulsar pl PSUPS20A12E 5 Fig 4 The view of the PSU...

Страница 6: ...harging Total current of the receivers battery 14A max see chart 1 Output voltage adjustment range 12 14V DC Ripple voltage 120mV p p max PSU current consumption 0 3A Battery charging current 2A 4A 8A...

Страница 7: ...ration safety Protection class PN EN 60950 1 2007 I first Protection grade PN EN 60529 2002 U IP20 Electrical strength of insulation between input network circuit and output circuits of the PSU I P O...

Страница 8: ...ns 2 2 Installation procedure 1 Before installation make sure that the voltage in the 230V power supply circuit is cut off 2 Mount the PSU in a selected location and connect the wires 3 Connect the po...

Страница 9: ...module The modules of the recorder and CCTV cameras are protected against a short circuit by fuses fuse elements In case of fuse replacement use a replacement of the same parameters in conformity wit...

Страница 10: ...d to collect such WEEE separately CAUTION The power supply unit is adapted for a sealed lead acid battery SLA After the operation period it must not be disposed of but recycled according to the applic...

Отзывы: