background image

www.pulsar.pl 

 

 

 

 

PSUPS20A12E 

 

 

 

 

 
 

1.4. 

Specifications:  

electrical specifications (tab.4) 

mechanical specifications (tab.5) 

operation safety (tab.6) 

operating specifications (tab.7) 

 

    Table 4. Electrical specifications.

 

PSU type 

A (EPS - External Power Source) 

Mains supply 

176÷264V AC / 50Hz  

Current consumption 

1,5A @230V AC 

PSU’s power 

264W  

Efficiency 

85% 

Power factor PF 

>0,95 @230V AC 

Output voltage 

– Fuse base for fuse strips 

16x 
 
Output voltage 

– recorder 

11V÷13,8V DC – buffer operation 
9,5V÷13,8V DC – battery-assisted operation 
 

12V DC

 maintained regardless of the state of battery charge 

Output current t

AMB

<30°C 

16x0,8A + 5A re 2A battery charging* 
16x0,7A + 5A re 4A battery charging* 
16x0,4A + 5A re 8A battery charging

Total current of the rec battery 20A

*

 max. 

*

 

see chart 1 

Output current t

AMB

=40°C

 

16x0,4A + 5A re 2A battery charging

 * 

Total current of the rec battery 14A* max. 
* see chart 1 

Output voltage adjustment range 

12

÷14V DC 

Ripple voltage 

120mV p-p max. 

PSU current consumption 

0,3A 

Battery charging current 

2A, 4A, 8A jumper selectable 

Approximate backup time 

4h 15min 

Short-circuit protection SCP 

2x STRIP LB8:  16x F 1A glass fuse,  
Output filter 1xF 5A 

Overload protection OLP 

105% ÷ 150% of the PSU power, automatic recovery 

Battery circuit protection SCP and reverse 
polarity connection 

glass fuse 30A 

Surge protection 

varistors 

Over voltage protection OVP  

>16V (activation requires disconnecting the load or supply for 
about 20 s.) 

Deep discharge protection UVP 

U<9,5V (

± 5%) – disconnection of battery terminal 

Sabotage protection: 
- TAMPER output indicating enclosure 
opening 

 
- micro-switches, NC contacts (enclosure closed), 
0,5A@50V DC (max.) 

Optical indication: front panel of the PSU 
- AC OK.; LED indicating  the AC power 
status 
- AUX OK.; LED indicating  the DC supply at 
the PSU output 

 
- red, normal status 

– on, failure: off 

 
- green, normal status 

– on, failure: off 

             
 

 

 

                                                 

*

 

See chart 1 

 

Содержание PSUPS20A12E

Страница 1: ...PSUPS20A12E v 1 2 PSUPS 13 8V 12V 20A 65Ah Buffer power supply for 16 HD cameras and recorder EN Edition 5 from 15 11 2017 Supercedes the edition 4 from 20 04 2017 GREEN POWER CCTV...

Страница 2: ...output protection against short circuit and reverse polarity connection LED indication protections SCP short circuit protection OLP overload protection OVP over voltage protection OHP overheat protec...

Страница 3: ...ity consumption for own needs and the energy efficiency of the power intake track were taken into account The exact description of how to perform the calculations can be found at Approximate backup ti...

Страница 4: ...onent no Fig 4 Description PSU module PSB 30012200 Connectors of the PSU L N 230V AC power connector PE protection connector V V DC supply outputs B B battery output green LED indicates DC power P1 po...

Страница 5: ...www pulsar pl PSUPS20A12E 5 Fig 4 The view of the PSU...

Страница 6: ...harging Total current of the receivers battery 14A max see chart 1 Output voltage adjustment range 12 14V DC Ripple voltage 120mV p p max PSU current consumption 0 3A Battery charging current 2A 4A 8A...

Страница 7: ...ration safety Protection class PN EN 60950 1 2007 I first Protection grade PN EN 60529 2002 U IP20 Electrical strength of insulation between input network circuit and output circuits of the PSU I P O...

Страница 8: ...ns 2 2 Installation procedure 1 Before installation make sure that the voltage in the 230V power supply circuit is cut off 2 Mount the PSU in a selected location and connect the wires 3 Connect the po...

Страница 9: ...module The modules of the recorder and CCTV cameras are protected against a short circuit by fuses fuse elements In case of fuse replacement use a replacement of the same parameters in conformity wit...

Страница 10: ...d to collect such WEEE separately CAUTION The power supply unit is adapted for a sealed lead acid battery SLA After the operation period it must not be disposed of but recycled according to the applic...

Отзывы: