6
Table 4. Mechanical parameters
Dimensions
W=400, H=350, D+D
1
=173+8 [+/- 2mm]
W
1
=405, H
1
=355 [+/- 2mm]
Fitting battery
360x175x165mm (WxHxD) max
Fixation
see figure 3
Net/gross weight
6,8 / 7,2 kg
Enclosure
Steel plate DC01, thickness: 1,0mm, colour: RAL 9003
Closing
Cheese head screw x 2 (at the front), lock assembly possible
Connectors
Power supply:
Φ0,63-2,50 (AWG 22-10)
Outputs: Φ0,63-2,50 (AWG 22-10),
Battery output BAT:
Ф6/2,5mm
2
TAMPER output: wires
Notes
The enclosure does not touch the assembly surface so that cables can be led.
Forced cooling - built-in fan.
Table 5. Operation safety
Protection class PN-EN 60950-1:2007
I (first)
Protection grade PN-EN 60529: 2002 (U)
IP20
Electrical strength of insulation:
- between input (network) circuit and output circuits of the PSU (I/P-O/P)
- between input circuit and PE protection circuit (I/P-FG)
- between output circuit and PE protection circuit (O/P-FG)
3000 V/AC min.
1500 V/AC min.
500 V/AC min.
Insulation resistance:
- between input circuit and output or protection circuit
100
MΩ, 500V/DC
Table 6. Operating parameters
Operating temperature
-
10ºC...+40ºC (see: chart 1)
Environmental class
II
Storage temperature
-
20ºC...+60ºC
Relative humidity
20%...90%, without condensation
Vibrations during operation
unacceptable
Impulse waves during operation
unacceptable
Direct insulation
unacceptable
Vibrations and impulse waves during transport
According to PN-83/T-42106