Pulsar PSDCB161220E Скачать руководство пользователя страница 5

www.pulsar.pl

                                                               

PSDCB161220E                                      

GREEN POWER CCTV

 

 

 

1.4 Specifications:  

         - electrical parameters (tab.3) 
         - mechanical parameters (tab.4) 
         - operation safety (tab.5) 
         - operating parameters (tab.6) 

 

      

Table 3. Electrical parameters  

Mains supply 

176÷264V AC  50Hz 

Current up to 

1,5A@230V AC max. 

Supply power 

300W max.  

Efficiency 

85% 

Power factor PF 

>0,95 @230V AC 

Output voltage 

11V÷13,8V DC – buffer operation 
9,5V÷13,8V DC – battery-assisted operation 

Output current t

AMB

<30°C 

16x1,1A + 2A battery charge - refer to chart 1 
16x1A + 4A battery charge - refer to chart 1 
16x0,75A + 8A battery charge - refer to chart 1 

Output current t

AMB

=40°C 

16x0,75A + 2A battery charge - refer to chart 1 
16x0,6A + 4A battery charge - refer to chart 1 

Voltage adjustment range 

12

÷14V DC 

Ripple  

120mV p-p max. 

Current consumption by PSU systems 

180mA 

Battery charge current 

2A/4A or 8A- jumper selectable 

Approximate backup time 

6h 15min 

Short-circuit protection SCP 

2x LB8 STRIP 
16x F 1A melting fuse 

Overload protection OLP 

105-150% of the PSU power, automatic return 

Battery circuit protection SCP and reverse  
polarity connection 

melting fuse 30A 

Surge protection 

varistors 

Overvoltage protection OVP 

>16V (activation requires disconnecting the load or 
supply for about 20 s.) 

Excessive discharge protection UVP 

U<9,5V (

± 5%) – disconnect of connection battery  

Sabotage protection: 
- TAMPER output indicating enclosure opening 

 
- microswitch, NC contacts (enclosure closed), 
0,5A@50V DC (max.) 

LED indication:  
- AC diode indicating AC power status 
- DC diode indicating DC power status at the PSU 
output 

 
- red, normal status 

– on, failure: off 

- green, normal status 

– on, failure: off 

F1÷F16 

F1A/250V 

 

 

 
       
 
 
 
 
 
 
 
 
 

Содержание PSDCB161220E

Страница 1: ...PSDCB161220E v 1 0 PSDCB 13 8V 20A 16x1A 65Ah Buffer power supply for up to 16 HD cameras EN Edition 3 from 15 11 2017 Supercedes the edition 2 from 24 04 2017 GREEN POWER CCTV ...

Страница 2: ...erse polarity connection LED indication protections SCP short circuit protection OVP overvoltage protection overvoltage protection AC input against sabotage overload protection OLP overheat protection OHP forced cooling built in fan warranty 2 year from the production date An example of power supply for HD cameras CONTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Descr...

Страница 3: ...e taken into account The exact description of how to perform the calculations can be found at Approximate backup time assumptions for calculations The PSU is constructed based on the switch mode PSU with high energy efficiency The PSU is housed in a metal enclosure colour RAL 9003 which can accommodate a 65Ah 12V battery A micro switch indicates door opening front cover The power supply housing ha...

Страница 4: ...ment no Fig 3 Description 1 PSU module 2 Connectors PSU L N power supply connector 230V AC Protection connector PE V V DC power output B B battery output 3 green LED indicates AC power 4 P1 potentiometer output voltage adjustment 5 Battery outputs red black 6 TAMPER contact of sabotage protection NC 7 Selection jumper for current Legend jumper installed jumper removed 8 Fuse module LB8 Fig 3 The v...

Страница 5: ...stment range 12 14V DC Ripple 120mV p p max Current consumption by PSU systems 180mA Battery charge current 2A 4A or 8A jumper selectable Approximate backup time 6h 15min Short circuit protection SCP 2x LB8 STRIP 16x F 1A melting fuse Overload protection OLP 105 150 of the PSU power automatic return Battery circuit protection SCP and reverse polarity connection melting fuse 30A Surge protection va...

Страница 6: ...007 I first Protection grade PN EN 60529 2002 U IP20 Electrical strength of insulation between input network circuit and output circuits of the PSU I P O P between input circuit and PE protection circuit I P FG between output circuit and PE protection circuit O P FG 3000 V AC min 1500 V AC min 500 V AC min Insulation resistance between input circuit and output or protection circuit 100 MΩ 500V DC ...

Страница 7: ...al system shall follow valid standards and regulations 2 2 Installation procedure 1 Before installation cut off the voltage in the 230V power supply circuit 2 Mount the PSU in a selected location and connect the wires 3 Connect the power cables 230V AV to L N clips of the PSU Connect the ground wire to the clip marked by the earth symbol PE PSU module connector Use a three core cable with a yellow...

Страница 8: ...disconnection 4 3 Maintenance Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply network The PSU does not require performing any specific maintenance measures however in case of significant dust rate its interior is recommended to be cleaned with compressed air In case of fuse replacement use a replacement of the same parameters WEEE MA...

Отзывы: