1.4. Specifications: 
- electrical specifications (tab.3) 
- mechanical specifications (tab.4) 
- operation safety (tab.5) 
- operating specifications (tab.6) 
 

Electrical specifications (tab. 3). 

Supply voltage 

176 ÷ 264 V AC 

Current consumption 

1,36A@230VAC max. 

Power frequency 

50Hz 

PSU power 

200 W max. 

Efficiency 

85% 

Output voltage 

12 V DC 

Output current 

16 x 0,8A 

Output voltage adjustment range 

12 V÷ 15 VDC  

Ripple voltage 

100mV p-p max. 

Short-circuit protection SCP  

LB8/AW (A , B) STRIP 
16x F 1A (fuse) or PTC 1,1A  
PSU MODULE 
105% ÷ 150% of PSU power, 
electronic current limiting, 

Overload protection OLP 

105% ÷ 150% of PSU power, 
electronic current limiting, 

Surge protection of the PSU outputs OVP 

>16V  (varistors) 

Technical outputs: 
- AW (A, B) outputs indicating fuse failure 
(blow), strips LB8/AW A, B (SCP 
activation) 

 
OC type, 50mA max, 
normal status: L level (0V), 
failure: hi-Z level 

F1÷ F8 fuses (strips A,B) 

F 1A/250V or PTC 1,1A (manual selection) 

Mechanical specifications (tab. 4). 

Enclosure 
dimensions 

285 x 261 x 58 (280 x 256 x 50)  (WxHxD) [mm] (+/- 2) 

Fixing 

247 x 225 x  

Φ

 6  (WxH) 

Net/gross weight 

2,23/2,40 kg 

Enclosure 

Steel plate, DC01 0,8mm colour: RAL 9003 

Closing 

Cheese-head screw: at the front 

Connectors 

Power supply: 230 V AC: 

Φ

0,63-2,05 (AWG 22-12) 

AUX outputs: 

Φ

0,51- 2,05 (AWG 24-12) 

LB8/AW: 

Φ

0,51- 2,05 (AWG 24-12) 

Notes 

The enclosure does not adjoin the assembly surface so that cables can be led

.

 

Operation safety (tab.5). 

Protection class PN-EN 60950-1:2007 

I (first) 

Protection grade PN-EN 60529: 2002 (U) 

IP20 

Electrical strength of insulation: 
- between input (network) circuit and output circuits of the PSU (I/P-O/P) 
- between input circuit and PE protection circuit (I/P-FG) 
- between output circuit and PE protection circuit (O/P-FG) 

 
3000 V/AC min. 
1500 V/AC min. 
500  V/AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 
100 M

, 500V/DC  

Operating specifications (tab.6). 

Operating temperature 

-10ºC...+40ºC  

Storage temperature 

-20ºC...+60ºC 

Relative humidity 

20%...90%, without condensation 

Vibrations during operation 

unacceptable 

Impulse waves during operation 

unacceptable 

Direct insolation 

unacceptable 

Vibrations and impulse waves during transport 

PN-83/T-42106 

 
 
 

Содержание PSDC 161214

Страница 1: ...PSDC 161214 v 1 0 PSDC 12V 14A 16x1A Switched mode power supply for CCTV EN Edition 1st 10th Mar2012 ...

Страница 2: ... procedure 3 Operating status indication 3 1 LED indication of operating status 3 2 Technical outputs 4 Operation and use 4 1 Overload or short circuit of the PSU output 4 2 Battery assisted operation 4 3 Maintenance 1 Technical description 1 1 General description A regulated PSU is intended for supplying alarm systems devices requiring stabilised voltage of 12V DC 12 0V 15 0V DC and current effic...

Страница 3: ...vation 6 AW output indicating failure of a particular output OC type normal status L failure hi Z 7 Jumper for the selection of the fuse type Fx Fx x Fx jumper on polyswitch Fx Fx x Fx x jumper off fuse Fig 2 The view of the PSU s pcb Table 2 Elements of the PSU see fig 3 Element no Description 1 L N 230 V AC power connectors PE protection connector 2 LED indication of DC power status main module ...

Страница 4: ...www pulsar pl PSDC161214 4 Fig 3 The view of the PSU ...

Страница 5: ...ensions 285 x 261 x 58 280 x 256 x 50 WxHxD mm 2 Fixing 247 x 225 x Φ 6 WxH Net gross weight 2 23 2 40 kg Enclosure Steel plate DC01 0 8mm colour RAL 9003 Closing Cheese head screw at the front Connectors Power supply 230 V AC Φ0 63 2 05 AWG 22 12 AUX outputs Φ0 51 2 05 AWG 24 12 LB8 AW Φ0 51 2 05 AWG 24 12 Notes The enclosure does not adjoin the assembly surface so that cables can be led Operatio...

Страница 6: ... the connection board through the bushing The shock protection circuit shall be performed with a particular care i e the yellow and green wire coat of the power cable shall stick to one side of the terminal marked with the earth symbol in the PSU enclosure Operation of the power supply without a properly made and fully operational shock protection circuit is UNACCEPTABLE It can result in device da...

Страница 7: ...e fuse of the same parameters in case of a failure If the polyswitch assisted protection has been chosen there will be an automatic disconnection of the output voltage indicated by the green diode going out Then cut off the load from the PSU output for approx 1 minute 4 2 Procedure in case of activating the PSU OVP system When the OVP system is activated the output voltage is automatically cut off...

Страница 8: ...o provide warranty repairs at the earliest convenience however not later that within 14 days from the delivery to the service centre of the manufacturer 7 The repair period mentioned in item 6 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 8 All the services ren...

Отзывы: